Araştırma Makalesi

Comparison of sterilization times in membrane filter devices with microbial suspensions at different concentrations.

Cilt: 2 Sayı: 1(3) 1 Haziran 2017
  • Özge Gündoğdu Güngör
  • Burcu Aslaner
  • Fatih Sultan Kazdal
  • Ayfer Kına
  • Necla Erdi
  • Gülcan Turan
  • Gani Orhan
  • BÜŞRA Sarım
PDF İndir
EN

Comparison of sterilization times in membrane filter devices with microbial suspensions at different concentrations.

Abstract

Introduction. Sterilization of the membrane filter device used in water microbiology analysis is very important. Aim of the study. To compare the efficacy of sterilization by burning with alcohol and flaming with a Bunsen burner. Material and methods. Bacterial suspensions were prepared at different concentrations and for each concentration, each analyst studied 10 culture media for each time periods. The contaminated membrane filter funnels with the prepared samples were sterilized by flaming for 10, 20, 40 and 60 seconds. Then, the membrane filter was placed and 100 ml of sterile distilled water was filtered. Membrane filter was placed on appropriate growth medium and it was incubated. The same procedure was also carried out by burning with alcohol. Results. At 102 concentration, bacterial growth was not observed. At 103 concentration, bacterial growth was observed 6,66% of growth medium at 10 seconds. At 104 concentration, bacterial growth was observed 30% of growth medium at 10 seconds and 23,3% of growth medium at 20 seconds. At 105, 106 and 107 concentrations, bacterial growth was observed in different percentages at all the time periods. Bacterial growth was not observed in sterilization using alcohol burning technique at all the time periods. Conclusions. Effective sterilization can be achieved by flame with Bunsen burner with low microbial concentration suspensions and low time periods. At high concentration suspensions, membrane filter device can be effectively sterilized by burning with alcohol.

Key words: sterilization, sanitation, E.coli, Pseudomonas aeruginosa, membrane filter device, water quality.

Keywords

Kaynakça

  1. NO*, Büşra Sarım*, Burcu Aslaner*, Fatih Sultan Kazdal*, Ayfer Kına*, Necla Erdi*, Gülcan Turan*, Gani Orhan* *Istanbul Public Health Laboratory Number 3, Istanbul, Turkey.

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

Araştırma Makalesi

Yazarlar

Özge Gündoğdu Güngör Bu kişi benim

Burcu Aslaner Bu kişi benim

Fatih Sultan Kazdal Bu kişi benim

Ayfer Kına Bu kişi benim

Necla Erdi Bu kişi benim

Gülcan Turan Bu kişi benim

Gani Orhan Bu kişi benim

BÜŞRA Sarım Bu kişi benim

Yayımlanma Tarihi

1 Haziran 2017

Gönderilme Tarihi

14 Temmuz 2017

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2017 Cilt: 2 Sayı: 1(3)

Kaynak Göster

APA
Gündoğdu Güngör, Ö., Aslaner, B., Kazdal, F. S., Kına, A., Erdi, N., Turan, G., Orhan, G., & Sarım, B. (2017). Comparison of sterilization times in membrane filter devices with microbial suspensions at different concentrations. The Turkish Journal Of Occupational / Environmental Medicine and Safety, 2(1(3), 328-334. https://izlik.org/JA98EX93YJ
AMA
1.Gündoğdu Güngör Ö, Aslaner B, Kazdal FS, vd. Comparison of sterilization times in membrane filter devices with microbial suspensions at different concentrations. turjoem. 2017;2(1(3):328-334. https://izlik.org/JA98EX93YJ
Chicago
Gündoğdu Güngör, Özge, Burcu Aslaner, Fatih Sultan Kazdal, vd. 2017. “Comparison of sterilization times in membrane filter devices with microbial suspensions at different concentrations”. The Turkish Journal Of Occupational / Environmental Medicine and Safety 2 (1(3): 328-34. https://izlik.org/JA98EX93YJ.
EndNote
Gündoğdu Güngör Ö, Aslaner B, Kazdal FS, Kına A, Erdi N, Turan G, Orhan G, Sarım B (01 Haziran 2017) Comparison of sterilization times in membrane filter devices with microbial suspensions at different concentrations. The Turkish Journal Of Occupational / Environmental Medicine and Safety 2 1(3) 328–334.
IEEE
[1]Ö. Gündoğdu Güngör vd., “Comparison of sterilization times in membrane filter devices with microbial suspensions at different concentrations”., turjoem, c. 2, sy 1(3), ss. 328–334, Haz. 2017, [çevrimiçi]. Erişim adresi: https://izlik.org/JA98EX93YJ
ISNAD
Gündoğdu Güngör, Özge - Aslaner, Burcu - Kazdal, Fatih Sultan - Kına, Ayfer - Erdi, Necla - Turan, Gülcan - Orhan, Gani - Sarım, BÜŞRA. “Comparison of sterilization times in membrane filter devices with microbial suspensions at different concentrations”. The Turkish Journal Of Occupational / Environmental Medicine and Safety 2/1(3) (01 Haziran 2017): 328-334. https://izlik.org/JA98EX93YJ.
JAMA
1.Gündoğdu Güngör Ö, Aslaner B, Kazdal FS, Kına A, Erdi N, Turan G, Orhan G, Sarım B. Comparison of sterilization times in membrane filter devices with microbial suspensions at different concentrations. turjoem. 2017;2:328–334.
MLA
Gündoğdu Güngör, Özge, vd. “Comparison of sterilization times in membrane filter devices with microbial suspensions at different concentrations”. The Turkish Journal Of Occupational / Environmental Medicine and Safety, c. 2, sy 1(3), Haziran 2017, ss. 328-34, https://izlik.org/JA98EX93YJ.
Vancouver
1.Özge Gündoğdu Güngör, Burcu Aslaner, Fatih Sultan Kazdal, Ayfer Kına, Necla Erdi, Gülcan Turan, Gani Orhan, BÜŞRA Sarım. Comparison of sterilization times in membrane filter devices with microbial suspensions at different concentrations. turjoem [Internet]. 01 Haziran 2017;2(1(3):328-34. Erişim adresi: https://izlik.org/JA98EX93YJ