BibTex RIS Kaynak Göster

SELECTIVE AND SENSITIVE DETERMINATION OF TANNIC ACID USING A 1-BENZOYL-3-(PYRROLIDINE) THIOUREAFILM MODIFIED GLASSY CARBON ELECTRODE

Yıl 2017, Cilt: Volume 2 Sayı: İssue 1 (1) - 2.İnternational Congress Of Forensic Toxicology, 117 - 117, 16.02.2017

Öz

In this study
the selective determination of tannic acid (TA) was performed using a glassy
carbon (GC) electrode modified with 1-Benzoyl-3-(pyrrolidine) thiourea (PrTu).
PrTuwas deposited on the GC electrode in nonaqueous media by cyclic
voltammetry. PrTu-GC electrode demonstrated an electrocatalytical effect on the
oxidation of TA using differential pulse voltammetry (DPV) method in 0.1 M
Britton Robinson (BR) buffer solution of pH 2. Under optimum conditions linear
calibration graphs were obtained over the TA concentration range 2.0×10−6 to
4.2×10−5 M. The detection of limit (LOD) was found as 0.6 µM. The proposed
electrode was applied to the determination of TA in tea sample with
satisfactory results.

Kaynakça

  • Elif ÇALIK, Demet UZUN, Ümmihan Taşkoparan YILMAZ
  • Gazi University, Polatlı Science and Art Faculty, Department of Chemistry, 06900 Polatlı, Ankara/Turkey Gazi University, Science Faculty, Department of Chemistry, 06500, Ankara/Turkey
Yıl 2017, Cilt: Volume 2 Sayı: İssue 1 (1) - 2.İnternational Congress Of Forensic Toxicology, 117 - 117, 16.02.2017

Öz

Kaynakça

  • Elif ÇALIK, Demet UZUN, Ümmihan Taşkoparan YILMAZ
  • Gazi University, Polatlı Science and Art Faculty, Department of Chemistry, 06900 Polatlı, Ankara/Turkey Gazi University, Science Faculty, Department of Chemistry, 06500, Ankara/Turkey
Toplam 2 adet kaynakça vardır.

Ayrıntılar

Bölüm Articles
Yazarlar

Elif Çalık Bu kişi benim

Demet Uzun Bu kişi benim

Ümmihan Taşkoparan Yılmaz Bu kişi benim

Yayımlanma Tarihi 16 Şubat 2017
Yayımlandığı Sayı Yıl 2017 Cilt: Volume 2 Sayı: İssue 1 (1) - 2.İnternational Congress Of Forensic Toxicology

Kaynak Göster

APA Çalık, E., Uzun, D., & Yılmaz, Ü. T. (2017). SELECTIVE AND SENSITIVE DETERMINATION OF TANNIC ACID USING A 1-BENZOYL-3-(PYRROLIDINE) THIOUREAFILM MODIFIED GLASSY CARBON ELECTRODE. The Turkish Journal Of Occupational / Environmental Medicine and Safety, Volume 2(İssue 1 (1), 117-117.
AMA Çalık E, Uzun D, Yılmaz ÜT. SELECTIVE AND SENSITIVE DETERMINATION OF TANNIC ACID USING A 1-BENZOYL-3-(PYRROLIDINE) THIOUREAFILM MODIFIED GLASSY CARBON ELECTRODE. turjoem. Şubat 2017;Volume 2(İssue 1 (1):117-117.
Chicago Çalık, Elif, Demet Uzun, ve Ümmihan Taşkoparan Yılmaz. “SELECTIVE AND SENSITIVE DETERMINATION OF TANNIC ACID USING A 1-BENZOYL-3-(PYRROLIDINE) THIOUREAFILM MODIFIED GLASSY CARBON ELECTRODE”. The Turkish Journal Of Occupational / Environmental Medicine and Safety Volume 2, sy. İssue 1 (1) (Şubat 2017): 117-17.
EndNote Çalık E, Uzun D, Yılmaz ÜT (01 Şubat 2017) SELECTIVE AND SENSITIVE DETERMINATION OF TANNIC ACID USING A 1-BENZOYL-3-(PYRROLIDINE) THIOUREAFILM MODIFIED GLASSY CARBON ELECTRODE. The Turkish Journal Of Occupational / Environmental Medicine and Safety Volume 2 İssue 1 (1) 117–117.
IEEE E. Çalık, D. Uzun, ve Ü. T. Yılmaz, “SELECTIVE AND SENSITIVE DETERMINATION OF TANNIC ACID USING A 1-BENZOYL-3-(PYRROLIDINE) THIOUREAFILM MODIFIED GLASSY CARBON ELECTRODE”, turjoem, c. Volume 2, sy. İssue 1 (1), ss. 117–117, 2017.
ISNAD Çalık, Elif vd. “SELECTIVE AND SENSITIVE DETERMINATION OF TANNIC ACID USING A 1-BENZOYL-3-(PYRROLIDINE) THIOUREAFILM MODIFIED GLASSY CARBON ELECTRODE”. The Turkish Journal Of Occupational / Environmental Medicine and Safety VOLUME 2/İssue 1 (1) (Şubat 2017), 117-117.
JAMA Çalık E, Uzun D, Yılmaz ÜT. SELECTIVE AND SENSITIVE DETERMINATION OF TANNIC ACID USING A 1-BENZOYL-3-(PYRROLIDINE) THIOUREAFILM MODIFIED GLASSY CARBON ELECTRODE. turjoem. 2017;Volume 2:117–117.
MLA Çalık, Elif vd. “SELECTIVE AND SENSITIVE DETERMINATION OF TANNIC ACID USING A 1-BENZOYL-3-(PYRROLIDINE) THIOUREAFILM MODIFIED GLASSY CARBON ELECTRODE”. The Turkish Journal Of Occupational / Environmental Medicine and Safety, c. Volume 2, sy. İssue 1 (1), 2017, ss. 117-.
Vancouver Çalık E, Uzun D, Yılmaz ÜT. SELECTIVE AND SENSITIVE DETERMINATION OF TANNIC ACID USING A 1-BENZOYL-3-(PYRROLIDINE) THIOUREAFILM MODIFIED GLASSY CARBON ELECTRODE. turjoem. 2017;Volume 2(İssue 1 (1):117-.