Background: The objective of this study was to compare the results of the LigaSure® Precise vessel sealing system and conventional suture ligation CSL for total thyroidectomy in terms of complication rates, hospitalization, and surgical time. Materials and Methods: This non-randomized retrospective review included 118 consecutive patients. All patients with nodular or multinodular goiter underwent total thyroidectomy by a single surgeon. The patients were divided into two subgroups: CSL was used as the conventional method together with monopolar and bipolar cautery group 1 , and LigaSure® Precise L was used in group 2 as a sealing system for all surrounding tissues of the thyroid gland. Results: No statistically significant differences were found between the two techniques with respect to age, sex, surgical time, hospitalization, and postoperative complications p>0.05 . Conclusion: Sutureless thyroid operations with Ligasure can be safely performed without the presence of higher complication risks but does not reduce surgical time or hospitalization.
LigaSure conventional suture ligation complication total thyroidectomy
Birincil Dil | İngilizce |
---|---|
Bölüm | Research Article |
Yazarlar | |
Yayımlanma Tarihi | 1 Ocak 2019 |
Yayımlandığı Sayı | Yıl 2019 |