Araştırma Makalesi

A Comparison of the Multivariate Calibration Methods with Feature Selection for Gas Sensors’ Long‐Term Drift Effect

Cilt: 11 Sayı: 3 30 Aralık 2019
PDF İndir
EN TR

A Comparison of the Multivariate Calibration Methods with Feature Selection for Gas Sensors’ Long‐Term Drift Effect

Öz

In many electronic nose applications where gas sensors utilizing for a long time, there is an undesirable drift effect on the sensors, which affects the classification quality negatively. Although the sensor drift is inevitable, it is possible to reduce this effect with the calibration transfer methods. This paper presents a comparison study of various multivariate standardization methods to facilitate an effective calibration way on a comprehensive dataset, which is reachable on‐line. In this study, three methods applied: direct standardization (DS) orthogonal signal correction (OSC) and piecewise direct standardization (PDS). In addition, these three methods are applied data, which consisted of selected features. The results have shown that the classification success has increased with multivariate calibration technique applied to the selected features. The results also demonstrate that using the best features in the signal processing part can play an important role for the calibration

Anahtar Kelimeler

Kaynakça

  1. Artursson, T., Eklöv, T., Lundström, I., Martensson, P., Sjöström, M., and Holmberg, M. 2000. Drift correction for gas sensors using multivariate methods. J. Chemomet, vol. 14, pp. 711‐723.
  2. Chandrashekar, G. and Sahin, F. 2014. A survey on feature selection methods, Computers and Electrical Engineering, vol. 40, pp. 16‐28.
  3. Fernandez, L. Guney, S., Gutierrez‐Galvez, A. and Marco, S. 2016. Calibration transfer in temperature modulated gas sensor arrays, Sensors and Actuat. B, Chem., vol. 231, pp. 276‐284.
  4. Feudale, R. N., Woody, N. A., Tan, H., Myles, A. J., Brown, S. D. and Ferre, J. 2002. Transfer of mulivariate calibration models: A review. Chemomet. Intell. Lab. Syst., vol. 64, pp. 181‐192.
  5. Galvãoa, R. K. H., Soares, S. F. C., Martins, M. N., Pimentel, M. F. and Araújo, M. C. U. 2015. Calibration transfer employing univariate correction and robust regression, Anal. Chim. Acta., vol. 864, pp. 1‐8.
  6. Haugen, J., Tomic, O., and Kvaal, K. 2000. A calibration method for handling the temporal drift of solid state gassensors, Anal. Chim. Acta, vol. 407, pp. 23‐39.
  7. Malli, B., Birlutiu, A. and Natschläger, T. 2017. Standard‐free calibration transfer ‐ An evaluation of different techniques, Chemomet. Intell. Lab. Syst., vol. 161, pp. 49‐60.
  8. Panchuk, V., Kirsanov, D., Oleneva, E., Semenov, V., Legin, A. 2017. Calibration transfer between different analytical methods, Talanta, vol. 170, pp. 457‐463.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Elektrik Mühendisliği

Bölüm

Araştırma Makalesi

Yazarlar

Gülnur Begüm Ergün * Bu kişi benim
Türkiye

Yayımlanma Tarihi

30 Aralık 2019

Gönderilme Tarihi

17 Kasım 2018

Kabul Tarihi

4 Eylül 2019

Yayımlandığı Sayı

Yıl 2019 Cilt: 11 Sayı: 3

Kaynak Göster

APA
Ergün, G. B., & Güney, S. (2019). A Comparison of the Multivariate Calibration Methods with Feature Selection for Gas Sensors’ Long‐Term Drift Effect. Uluslararası Teknolojik Bilimler Dergisi, 11(3), 170-176. https://izlik.org/JA27DM53HT
AMA
1.Ergün GB, Güney S. A Comparison of the Multivariate Calibration Methods with Feature Selection for Gas Sensors’ Long‐Term Drift Effect. UTBD. 2019;11(3):170-176. https://izlik.org/JA27DM53HT
Chicago
Ergün, Gülnur Begüm, ve Selda Güney. 2019. “A Comparison of the Multivariate Calibration Methods with Feature Selection for Gas Sensors’ Long‐Term Drift Effect”. Uluslararası Teknolojik Bilimler Dergisi 11 (3): 170-76. https://izlik.org/JA27DM53HT.
EndNote
Ergün GB, Güney S (01 Aralık 2019) A Comparison of the Multivariate Calibration Methods with Feature Selection for Gas Sensors’ Long‐Term Drift Effect. Uluslararası Teknolojik Bilimler Dergisi 11 3 170–176.
IEEE
[1]G. B. Ergün ve S. Güney, “A Comparison of the Multivariate Calibration Methods with Feature Selection for Gas Sensors’ Long‐Term Drift Effect”, UTBD, c. 11, sy 3, ss. 170–176, Ara. 2019, [çevrimiçi]. Erişim adresi: https://izlik.org/JA27DM53HT
ISNAD
Ergün, Gülnur Begüm - Güney, Selda. “A Comparison of the Multivariate Calibration Methods with Feature Selection for Gas Sensors’ Long‐Term Drift Effect”. Uluslararası Teknolojik Bilimler Dergisi 11/3 (01 Aralık 2019): 170-176. https://izlik.org/JA27DM53HT.
JAMA
1.Ergün GB, Güney S. A Comparison of the Multivariate Calibration Methods with Feature Selection for Gas Sensors’ Long‐Term Drift Effect. UTBD. 2019;11:170–176.
MLA
Ergün, Gülnur Begüm, ve Selda Güney. “A Comparison of the Multivariate Calibration Methods with Feature Selection for Gas Sensors’ Long‐Term Drift Effect”. Uluslararası Teknolojik Bilimler Dergisi, c. 11, sy 3, Aralık 2019, ss. 170-6, https://izlik.org/JA27DM53HT.
Vancouver
1.Gülnur Begüm Ergün, Selda Güney. A Comparison of the Multivariate Calibration Methods with Feature Selection for Gas Sensors’ Long‐Term Drift Effect. UTBD [Internet]. 01 Aralık 2019;11(3):170-6. Erişim adresi: https://izlik.org/JA27DM53HT

Dergi isminin Türkçe kısaltması "UTBD" ingilizce kısaltması "IJTS" şeklindedir.

Dergimizde yayınlanan makalelerin tüm bilimsel sorumluluğu yazar(lar)a aittir. Editör, yardımcı editör ve yayıncı dergide yayınlanan yazılar için herhangi bir sorumluluk kabul etmez.