Araştırma Makalesi

AMBIENT VIBRATION ANALYSIS of an INDUSTRIAL BUILDING

Cilt: 26 Sayı: 1 30 Nisan 2021
PDF İndir
EN TR

AMBIENT VIBRATION ANALYSIS of an INDUSTRIAL BUILDING

Öz

Due to the heavy and dynamic equipment, the vibration and resonance effects that are not encountered under static dead loading may amplify over time in industrial buildings. This might cause damage to the structural system and create human comfort problems while the structure is in service. In this study, ambient vibration testing of a building composed of reinforced concrete and steel structural systems and located at a boron processing plant in Turkey was performed. The velocities and accelerations caused by the sieve shaker system attached to the structure with springs, are evaluated under the effect of sample loading. 

Anahtar Kelimeler

Kaynakça

  1. Altunisik, A.C., Bayraktar, A. and Genc, A.F. (2015) Determination of the restoration effect on the structural behavior of masonry arch bridges, Smart Struct. Syst., 16(1), 101-139. DOI : 10.12989/sss.2015.16.1.101
  2. Altunisik, A.C., Bayraktar, A., Sevim, B. and Birinci F. (2011) Vibration-based operational modal analysis of the Mikron historic arch bridge after restoration, Civil Eng. Environ. Syst., 28(3), 247-259. DOI : 10.1080/10286608.2011.588328
  3. Aras, F. and Altay, G. (2015) Investigation of mechanical properties of masonry in historic buildings, Gradevinar, 67(5). DOI : 10.14256/JCE.1145.2014
  4. Brincker, R., Ventura, C., and Andersen, P. (2003) Why ouput-only modal testing is a desirable tool for a wide range of practical applications, In 21st international Modal Analysis Conference (IMAC), Kissimmee, Florida.
  5. DIN 4150 - 3 (1999) Vibrations in Buildings, Germany.
  6. Ewins, D. J. (1995) Modal Testing: Theory and Practice, John Wiley & Sons, New York. ISBN: 978-0-863-80218-8
  7. Michel, C., Gueguen, P. and Bard, P.Y. (2008) Dynamic parameters of structures extracted from ambient vibration measurements: An aid for the seismic vulnerability assessment of existing buildings in moderate seismic hazard regions, Soil Dynamics and Earthquake Engineering, 28, 593–604. DOI : 10.1016/j.soildyn.2007.10.002
  8. Bayraktar, A., Temel, T., Altunışık, A. C., Sevim, B., Şahin, A. and Özcan, M. (2010) Binaların dinamik parametrelerinin operasyonal modal analiz yöntemiyle belirlenmesi, İMO Teknik Dergi, 5185-5205, Yazı 337.

Ayrıntılar

Birincil Dil

İngilizce

Konular

İnşaat Mühendisliği

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

30 Nisan 2021

Gönderilme Tarihi

24 Temmuz 2020

Kabul Tarihi

3 Ocak 2021

Yayımlandığı Sayı

Yıl 2021 Cilt: 26 Sayı: 1

Kaynak Göster

APA
Kartal, H., Dere, Y., & Arslan, M. H. (2021). AMBIENT VIBRATION ANALYSIS of an INDUSTRIAL BUILDING. Uludağ Üniversitesi Mühendislik Fakültesi Dergisi, 26(1), 47-64. https://doi.org/10.17482/uumfd.773354
AMA
1.Kartal H, Dere Y, Arslan MH. AMBIENT VIBRATION ANALYSIS of an INDUSTRIAL BUILDING. UUJFE. 2021;26(1):47-64. doi:10.17482/uumfd.773354
Chicago
Kartal, Hüseyin, Yunus Dere, ve Musa Hakan Arslan. 2021. “AMBIENT VIBRATION ANALYSIS of an INDUSTRIAL BUILDING”. Uludağ Üniversitesi Mühendislik Fakültesi Dergisi 26 (1): 47-64. https://doi.org/10.17482/uumfd.773354.
EndNote
Kartal H, Dere Y, Arslan MH (01 Nisan 2021) AMBIENT VIBRATION ANALYSIS of an INDUSTRIAL BUILDING. Uludağ Üniversitesi Mühendislik Fakültesi Dergisi 26 1 47–64.
IEEE
[1]H. Kartal, Y. Dere, ve M. H. Arslan, “AMBIENT VIBRATION ANALYSIS of an INDUSTRIAL BUILDING”, UUJFE, c. 26, sy 1, ss. 47–64, Nis. 2021, doi: 10.17482/uumfd.773354.
ISNAD
Kartal, Hüseyin - Dere, Yunus - Arslan, Musa Hakan. “AMBIENT VIBRATION ANALYSIS of an INDUSTRIAL BUILDING”. Uludağ Üniversitesi Mühendislik Fakültesi Dergisi 26/1 (01 Nisan 2021): 47-64. https://doi.org/10.17482/uumfd.773354.
JAMA
1.Kartal H, Dere Y, Arslan MH. AMBIENT VIBRATION ANALYSIS of an INDUSTRIAL BUILDING. UUJFE. 2021;26:47–64.
MLA
Kartal, Hüseyin, vd. “AMBIENT VIBRATION ANALYSIS of an INDUSTRIAL BUILDING”. Uludağ Üniversitesi Mühendislik Fakültesi Dergisi, c. 26, sy 1, Nisan 2021, ss. 47-64, doi:10.17482/uumfd.773354.
Vancouver
1.Hüseyin Kartal, Yunus Dere, Musa Hakan Arslan. AMBIENT VIBRATION ANALYSIS of an INDUSTRIAL BUILDING. UUJFE. 01 Nisan 2021;26(1):47-64. doi:10.17482/uumfd.773354

DUYURU:

30.03.2021- Nisan 2021 (26/1) sayımızdan itibaren TR-Dizin yeni kuralları gereği, dergimizde basılacak makalelerde, ilk gönderim aşamasında Telif Hakkı Formu yanısıra, Çıkar Çatışması Bildirim Formu ve Yazar Katkısı Bildirim Formu da tüm yazarlarca imzalanarak gönderilmelidir. Yayınlanacak makalelerde de makale metni içinde "Çıkar Çatışması" ve "Yazar Katkısı" bölümleri yer alacaktır. İlk gönderim aşamasında doldurulması gereken yeni formlara "Yazım Kuralları" ve "Makale Gönderim Süreci" sayfalarımızdan ulaşılabilir. (Değerlendirme süreci bu tarihten önce tamamlanıp basımı bekleyen makalelerin yanısıra değerlendirme süreci devam eden makaleler için, yazarlar tarafından ilgili formlar doldurularak sisteme yüklenmelidir).  Makale şablonları da, bu değişiklik doğrultusunda güncellenmiştir. Tüm yazarlarımıza önemle duyurulur.

Bursa Uludağ Üniversitesi, Mühendislik Fakültesi Dekanlığı, Görükle Kampüsü, Nilüfer, 16059 Bursa. Tel: (224) 294 1907, Faks: (224) 294 1903, e-posta: mmfd@uludag.edu.tr