Araştırma Makalesi

Comparison of Linear Measurements and Bolton Analysis on the Model Obtained from Conventional Method with OrthoCAD Software

Cilt: 2 Sayı: 2 19 Aralık 2021
PDF İndir
TR EN

Comparison of Linear Measurements and Bolton Analysis on the Model Obtained from Conventional Method with OrthoCAD Software

Öz

The aim of this study is to compare the arc length deviation, arc length, Bolton analysis, overjet and overbite values obtained from OrthoCAD software of plaster models, transferred to the three-dimensional environment with the iTero Element 2 intraoral scanner, with conventional methods. The study included plaster model obtained from a total of 30 individuals aged 18-25 years old, Angle Class I, Angle Class II and Angle Class III who obtained for orthodontic treatment. Models were digitized with iTero Element 2 intraoral scanners. To determine the arc length deviation, arc length, Bolton analysis, overjet and overbite, measurements were carried out on the models. The measurements were repeated 30 days apart from each other. For the characteristics considered, descriptive statistics are expressed as mean, standard deviation, minimum and maximum value. In terms of these characteristics, the paired sample t-test was used to compare the first and second measurement differences. In terms of arc length deviation, overjet, and overbite values, there was no statistically significant difference between the groups. A statistically significant difference was found between the two methods for lower arch length measurements. A statistically significant difference in the anterior ratio was found in the Bolton analysis, while no statistically significant difference in the overall ratio was observed. When compared to traditional approaches, the values obtained on the models obtained with the iTero 2 Element 3D scanner and the OrthoCAD software are thought to be accurate and alternative.

Anahtar Kelimeler

Kaynakça

  1. 1. Peluso MJ, Josell SD, Levine SW, Lorei BJ. Digital models: An introduction. Semin Orthod. 2004;10(3):226-38.
  2. 2. Stuart HW, Priest WR. Errors and discrepancies in measurement of tooth size. J Dent Res. 1960;39(2):405-14.
  3. 3. Rheude B, Sadowsky PL, Ferriera A, Jacobson A. An Evaluation of the use of digital study models in orthodontic diagnosis and treatment planning. Angle Orthod. 2005;75(3):300-4.
  4. 4. Fleming PS, Marinho V, Johal A. Orthodontic measurements on digital study models compared with plaster models: a Systematic Review. Orthod Craniofac Res. 2011;14(1):1-16.
  5. 5. Camardella LT, Breuning H, Vilella OV. Accuracy and reproducibility of measurements on plaster models and digital models created using an intraoral scanner. J Orofac Orthop Fortschritte Kieferorthopädie Organ Official J Dtsch Ges Für Kiefer. 2017;78(3):211-20.
  6. 6. Kau CH, Littlefield J, Rainy N, Nguyen JT, Creed B. Evaluation of CBCT digital models and traditional models using the Little’s Index. Angle Orthod. 2010;80(3):435-9.
  7. 7. Wiranto MG, Engelbrecht WP, Nolthenius HET, Meer WJ, Ren Y. Validity, reliability, and reproducibility of linear measurements on digital models obtained from intraoral and cone-beam computed tomography scans of alginate impressions. Am J Orthod Dentofac Orthop Off Publ Am Assoc Orthod Its Const Soc Am Board Orthod. 2013;143(1):140- 7.
  8. 8. Kravitz ND, Groth C, Jones PE, Graham JW, Redmond WR. Intraoral digital scanners. J Clin Orthod JCO. 2014;48(6):337-47.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Ortodonti ve Dentofasiyal Ortopedi

Bölüm

Araştırma Makalesi

Yazarlar

Seda Kotan
Türkiye

Selma Bilen Bu kişi benim
Türkiye

Yayımlanma Tarihi

19 Aralık 2021

Gönderilme Tarihi

26 Nisan 2021

Kabul Tarihi

4 Ekim 2021

Yayımlandığı Sayı

Yıl 2021 Cilt: 2 Sayı: 2

Kaynak Göster

APA
Tunca, M., Tunca, Y., Kotan, S., & Bilen, S. (2021). Comparison of Linear Measurements and Bolton Analysis on the Model Obtained from Conventional Method with OrthoCAD Software. Van Diş Hekimliği Dergisi, 2(2), 1-10. https://izlik.org/JA73CB87SN
AMA
1.Tunca M, Tunca Y, Kotan S, Bilen S. Comparison of Linear Measurements and Bolton Analysis on the Model Obtained from Conventional Method with OrthoCAD Software. VDJ. 2021;2(2):1-10. https://izlik.org/JA73CB87SN
Chicago
Tunca, Murat, Yasemin Tunca, Seda Kotan, ve Selma Bilen. 2021. “Comparison of Linear Measurements and Bolton Analysis on the Model Obtained from Conventional Method with OrthoCAD Software”. Van Diş Hekimliği Dergisi 2 (2): 1-10. https://izlik.org/JA73CB87SN.
EndNote
Tunca M, Tunca Y, Kotan S, Bilen S (01 Aralık 2021) Comparison of Linear Measurements and Bolton Analysis on the Model Obtained from Conventional Method with OrthoCAD Software. Van Diş Hekimliği Dergisi 2 2 1–10.
IEEE
[1]M. Tunca, Y. Tunca, S. Kotan, ve S. Bilen, “Comparison of Linear Measurements and Bolton Analysis on the Model Obtained from Conventional Method with OrthoCAD Software”, VDJ, c. 2, sy 2, ss. 1–10, Ara. 2021, [çevrimiçi]. Erişim adresi: https://izlik.org/JA73CB87SN
ISNAD
Tunca, Murat - Tunca, Yasemin - Kotan, Seda - Bilen, Selma. “Comparison of Linear Measurements and Bolton Analysis on the Model Obtained from Conventional Method with OrthoCAD Software”. Van Diş Hekimliği Dergisi 2/2 (01 Aralık 2021): 1-10. https://izlik.org/JA73CB87SN.
JAMA
1.Tunca M, Tunca Y, Kotan S, Bilen S. Comparison of Linear Measurements and Bolton Analysis on the Model Obtained from Conventional Method with OrthoCAD Software. VDJ. 2021;2:1–10.
MLA
Tunca, Murat, vd. “Comparison of Linear Measurements and Bolton Analysis on the Model Obtained from Conventional Method with OrthoCAD Software”. Van Diş Hekimliği Dergisi, c. 2, sy 2, Aralık 2021, ss. 1-10, https://izlik.org/JA73CB87SN.
Vancouver
1.Murat Tunca, Yasemin Tunca, Seda Kotan, Selma Bilen. Comparison of Linear Measurements and Bolton Analysis on the Model Obtained from Conventional Method with OrthoCAD Software. VDJ [Internet]. 01 Aralık 2021;2(2):1-10. Erişim adresi: https://izlik.org/JA73CB87SN