Research Article
BibTex RIS Cite

Investigation of Insulation Breakdown of 2XS(FL)2Y 87/150(170) kV High Voltage Power Cable and Electrical Measurement Tests

Year 2014, Volume: 2 Issue: 2, 284 - 294, 05.09.2014

Abstract

One of the most significant issues related to the safety of high voltage power cables is the degradation of their parts and materials. The performance of the power cables depends on the mechanical and electrical integrity of the insulator material. Micro-cracks in high voltage power cables can threaten the insulating properties of power cables. Therefore the occurrence of micro-cracks is undesirable in high voltage power cables. 2XS(FL)2Y 87/150(170) kV high voltage power cables use various solid insulation materials such as Cross-linked Polyethylene (XLPE) and Ethylene Propylene Rubber (EPR). Electrical measurements and chemical analysis are used to find out the most representative combination in high voltage power cable. In this study, 2XS(FL)2Y 87/150(170) kV high voltage power cable insulation breakdown were investigated and the applied electrical measurement tests are described for breakdown detection. The problems which encountered the direction of the breakdown detection and elimination, solution proposals and preventive measures are described.

References

  • Y. Saner, Güç Dağıtımı 3 (Enerji Dağıtımı), Birsen Yayınevi, İstanbul, (1998).
  • M. Özkaya, Yüksek Gerilim Tekniği Cilt-1 Statik Elektrik Alanı ve Boşalma Olayları, Birsen Yayınevi, İstanbul, (2008).
  • Türkiye Elektrik Kurumu (TEK), Elektrik Tesislerinde Koruma ve Kontrol, Elektrik Üretim İletim Müessesesi Röle ve Ölçü Aletleri Grup Müdürlüğü, Ankara, (1990).
  • W.A. Thue, Electrical Power Cable Engineering, Marcel Dekker, New York, (1999). Anonim, http://pektaskablo.com/Dokumanlar/5122012141626398.pdf, (Erişim tarihi: 19 Nisan, 2009).
  • International Electrotechnical Commission, IEC 60228, International Standard Conductors of Insulated Cables, Third Edition, 2004-11, Geneva, Switzerland, (2004).
  • E. Peschke, R. Von Olshausen, Cable Systems for High and Ultra High Voltages: Cable Designs and Accessories – Dimensions, Development and Testing, Kluwer Academic Publishers, (2000).
  • R. Bartnikas, K.D. Srivastava, Power and Communication Cables – Theory and Applications, IEEE Press, New York, (2000).
  • M. Acedo, I. Radu, F. Frutos, J.C. Filippini, P. Notingher Journal of Electrostatics 53(4) (2001) 267-294.
  • J.P. Crine, S. Pelissou, J.L. Parpal IEEE Transaction on Electrical Insulation 26(1) (1991) 140-1
  • A. Türkcan, İzolasyon Testleri, TEİAŞ Soma Elektrik Teknolojileri Geliştirme ve Eğitim Merkezi Müdürlüğü Yayınları, İstanbul, (1998).
  • T. Tanaka, A. Greenwood, Advanced Power Cable Technology Basic Concepts and Testing, Vol.1, CRC Press, Florida, USA, (1983).
  • Megger, The Lowdown on High Voltage DC Testing, AVTM22P-1, Revision B, November, (2002).
  • L.W. Meng, J.M. Pang Singapore Engineering (2001) 18-20.

2XS(FL)2Y 87/150(170) kV Yüksek Gerilim Güç Kablosu Yalıtım Arızasının İncelenmesi ve Elektriksel Ölçüm Testleri

Year 2014, Volume: 2 Issue: 2, 284 - 294, 05.09.2014

Abstract

Yüksek gerilim güç kablolarının güvenliği ile ilgili en önemli konulardan biri, güç kablolarına ait parça ve malzemelerin bozulmasıdır. Güç kablolarının performansı yalıtkan malzemenin mekaniksel ve elektriksel bütünlüğüne bağlıdır. Yüksek gerilim güç kablolarındaki mikro çatlaklar, güç kablolarının yalıtım özelliklerini tehdit edebilir. Bu nedenle yüksek gerilim güç kablolarında mikro çatlakların oluşması istenmez. 2XS(FL)2Y 87/150(170) kV yüksek gerilim güç kabloları çapraz bağlı polietilen (XLPE) ve etilen propilen kauçuk (EPR) gibi çeşitli katı yalıtım malzemelerini kullanır. Elektriksel ölçümler ve kimyasal analizler yüksek gerilim güç kablolarında en iyi örnek karışımı bulmak için kullanılır. Bu çalışmada, 2XS(FL)2Y 87/150(170) kV yüksek gerilim güç kablosunun yalıtım arızası incelenmiş ve arıza tespiti için uygulanan elektriksel ölçüm testleri anlatılmıştır. Arızanın tespit edilmesi ve yok edilmesi yönünde karşılaşılan sorunlar, çözüm önerileri ve önleyici tedbirler açıklanmıştır.

References

  • Y. Saner, Güç Dağıtımı 3 (Enerji Dağıtımı), Birsen Yayınevi, İstanbul, (1998).
  • M. Özkaya, Yüksek Gerilim Tekniği Cilt-1 Statik Elektrik Alanı ve Boşalma Olayları, Birsen Yayınevi, İstanbul, (2008).
  • Türkiye Elektrik Kurumu (TEK), Elektrik Tesislerinde Koruma ve Kontrol, Elektrik Üretim İletim Müessesesi Röle ve Ölçü Aletleri Grup Müdürlüğü, Ankara, (1990).
  • W.A. Thue, Electrical Power Cable Engineering, Marcel Dekker, New York, (1999). Anonim, http://pektaskablo.com/Dokumanlar/5122012141626398.pdf, (Erişim tarihi: 19 Nisan, 2009).
  • International Electrotechnical Commission, IEC 60228, International Standard Conductors of Insulated Cables, Third Edition, 2004-11, Geneva, Switzerland, (2004).
  • E. Peschke, R. Von Olshausen, Cable Systems for High and Ultra High Voltages: Cable Designs and Accessories – Dimensions, Development and Testing, Kluwer Academic Publishers, (2000).
  • R. Bartnikas, K.D. Srivastava, Power and Communication Cables – Theory and Applications, IEEE Press, New York, (2000).
  • M. Acedo, I. Radu, F. Frutos, J.C. Filippini, P. Notingher Journal of Electrostatics 53(4) (2001) 267-294.
  • J.P. Crine, S. Pelissou, J.L. Parpal IEEE Transaction on Electrical Insulation 26(1) (1991) 140-1
  • A. Türkcan, İzolasyon Testleri, TEİAŞ Soma Elektrik Teknolojileri Geliştirme ve Eğitim Merkezi Müdürlüğü Yayınları, İstanbul, (1998).
  • T. Tanaka, A. Greenwood, Advanced Power Cable Technology Basic Concepts and Testing, Vol.1, CRC Press, Florida, USA, (1983).
  • Megger, The Lowdown on High Voltage DC Testing, AVTM22P-1, Revision B, November, (2002).
  • L.W. Meng, J.M. Pang Singapore Engineering (2001) 18-20.
There are 13 citations in total.

Details

Primary Language Turkish
Subjects Engineering
Journal Section Articles
Authors

Nihat Pamuk This is me

Publication Date September 5, 2014
Published in Issue Year 2014 Volume: 2 Issue: 2

Cite

APA Pamuk, N. (2014). 2XS(FL)2Y 87/150(170) kV Yüksek Gerilim Güç Kablosu Yalıtım Arızasının İncelenmesi ve Elektriksel Ölçüm Testleri. Düzce Üniversitesi Bilim Ve Teknoloji Dergisi, 2(2), 284-294.
AMA Pamuk N. 2XS(FL)2Y 87/150(170) kV Yüksek Gerilim Güç Kablosu Yalıtım Arızasının İncelenmesi ve Elektriksel Ölçüm Testleri. DUBİTED. June 2014;2(2):284-294.
Chicago Pamuk, Nihat. “2XS(FL)2Y 87/150(170) KV Yüksek Gerilim Güç Kablosu Yalıtım Arızasının İncelenmesi Ve Elektriksel Ölçüm Testleri”. Düzce Üniversitesi Bilim Ve Teknoloji Dergisi 2, no. 2 (June 2014): 284-94.
EndNote Pamuk N (June 1, 2014) 2XS(FL)2Y 87/150(170) kV Yüksek Gerilim Güç Kablosu Yalıtım Arızasının İncelenmesi ve Elektriksel Ölçüm Testleri. Düzce Üniversitesi Bilim ve Teknoloji Dergisi 2 2 284–294.
IEEE N. Pamuk, “2XS(FL)2Y 87/150(170) kV Yüksek Gerilim Güç Kablosu Yalıtım Arızasının İncelenmesi ve Elektriksel Ölçüm Testleri”, DUBİTED, vol. 2, no. 2, pp. 284–294, 2014.
ISNAD Pamuk, Nihat. “2XS(FL)2Y 87/150(170) KV Yüksek Gerilim Güç Kablosu Yalıtım Arızasının İncelenmesi Ve Elektriksel Ölçüm Testleri”. Düzce Üniversitesi Bilim ve Teknoloji Dergisi 2/2 (June 2014), 284-294.
JAMA Pamuk N. 2XS(FL)2Y 87/150(170) kV Yüksek Gerilim Güç Kablosu Yalıtım Arızasının İncelenmesi ve Elektriksel Ölçüm Testleri. DUBİTED. 2014;2:284–294.
MLA Pamuk, Nihat. “2XS(FL)2Y 87/150(170) KV Yüksek Gerilim Güç Kablosu Yalıtım Arızasının İncelenmesi Ve Elektriksel Ölçüm Testleri”. Düzce Üniversitesi Bilim Ve Teknoloji Dergisi, vol. 2, no. 2, 2014, pp. 284-9.
Vancouver Pamuk N. 2XS(FL)2Y 87/150(170) kV Yüksek Gerilim Güç Kablosu Yalıtım Arızasının İncelenmesi ve Elektriksel Ölçüm Testleri. DUBİTED. 2014;2(2):284-9.