EN
Optimal Reactive Power Injection in Distribution Networks to Maximize Cost Savings Via AOA
Abstract
Utilities have been forced to raise the overall efficiency towards a better position in radial distribution systems (DS). The literature has proved that reactive power compensation performs well in minimizing the power loss ( PLoss ) and enhancing the bus voltage profile within the permissible range in radial DSs. This work presents Archimedes optimization algorithm (AOA) to resolve the problem efficiently. The merit of this technique is that it can offer a global or near-global optimum for capacitor siting and sizing. The main intention of this study is to obtain annual financial benefit (AFB) using the placement and sizing of capacitors optimally. This can, however, be achieved by minimizing the objective function composed of cost-based PLoss and capacitor investment cost on radial DSs. The proposed technique has been tested on four renowned DS: the Indian 10-bus, modified 12-bus, IEEE 69-bus, and 94-bus Portugal system. The previously published papers are compared with the outcomes of AOA in terms of PLoss reduction and AFB and prove that AOA achieves better performance and more AFB.
Keywords
References
- [1]. S. G.Ankaliki, A. D. Kulkarni, S. I. Katti “Hierarchical Compensation Technique for Loss Minimization in DistributionSystems,” IOSR Journal of Engineering (IOSRJEN), vol. 2, no. 2, pp. 356-362, February 2012.
- [2]. G. G. Soma, “Optimal Sizing and Placement of Capacitor Banks in Distribution Networks Using a Genetic Algorithm. Electricity,” MDPI, vol. 2, no. 2, pp. 187-204, May 2021.
- [3]. P. S. Babu, B. Pamuleti, M. P. Lalitha, “Optimal Capacitor Placement in Radial Distribution Systems Using Fuzzy and Advanced Harmony Search Algorithm for Loss Reduction,” International Journal of Engineering Research &Technology, vol. 2, no. 11, pp. 3256-60, November 2013.
- [4]. M. N.l Muhtazaruddin, J. J. Jamian, D. Nguyen, N. A. Jalalludin and G. Fujita, “Optimal capacitor placement and sizing via artificial bee colony,” International Journal of Smart Grid and Clean Energy, vol. 3, no. 2, pp. 200-206, April 2014.
- [5]. S. M. Tabatabaei, B. Vahidi, “Bacterial foraging solution based fuzzy logic decision for optimal capacitor allocation in radial distribution system,” Electric Power Systems Research, vol 81, pp. 1045-1050, April 2011. [6]. A. A. El-Fergany, “Optimal capacitor allocations using evolutionary algorithms,” IET Generation Transmission & Distribution, vol. 7, no. 6, pp. 593-601, June 2013.
- [7]. A. Elsheikh, Y. Helmy, Y. Abouelseoud, A. Elsherif, et al., “Optimal capacitor placement and sizing in radial electric power systems,” Alexandria Engineering Journal, vol. 53, no. 4, pp. 809-816, December 2014. [8]. B. Venkatesh, B. Ranjan, “Data structure for radial distribution load flow analysis,” In Proc. Of the IEE Proceeding in Generation, Transmission and Distribution, vol. 150, no. 1, pp. 101-106, January 2003.
- [9]. F. E. Riaño, J. F. Cruz, O. D. Montoya, H. R. Chamorro, L. Alvarado-Barrios, et al., “Reduction of Losses and Operating Costs in Distribution Networks Using a Genetic Algorithm and Mathematical Optimization,” Electronics, vol. 10, no. 419, pp. 1-25, February 2021.
- [10]. C. K. Reddy, G. Srinivasan, B. S. Lokasree, “Optimization of reactive power support in Power Distribution Network – An economically based study,” In Proceedings of the 7th International Conference on Electrical Energy Systems, February 2021.
Details
Primary Language
English
Subjects
Engineering
Journal Section
Research Article
Publication Date
September 30, 2023
Submission Date
March 25, 2023
Acceptance Date
August 24, 2023
Published in Issue
Year 2023 Volume: 10 Number: 3
APA
Srınıvasan, G., & M, L. (2023). Optimal Reactive Power Injection in Distribution Networks to Maximize Cost Savings Via AOA. El-Cezeri, 10(3), 538-553. https://doi.org/10.31202/ecjse.1270783
AMA
1.Srınıvasan G, M L. Optimal Reactive Power Injection in Distribution Networks to Maximize Cost Savings Via AOA. El-Cezeri Journal of Science and Engineering. 2023;10(3):538-553. doi:10.31202/ecjse.1270783
Chicago
Srınıvasan, G, and Lavanya M. 2023. “Optimal Reactive Power Injection in Distribution Networks to Maximize Cost Savings Via AOA”. El-Cezeri 10 (3): 538-53. https://doi.org/10.31202/ecjse.1270783.
EndNote
Srınıvasan G, M L (September 1, 2023) Optimal Reactive Power Injection in Distribution Networks to Maximize Cost Savings Via AOA. El-Cezeri 10 3 538–553.
IEEE
[1]G. Srınıvasan and L. M, “Optimal Reactive Power Injection in Distribution Networks to Maximize Cost Savings Via AOA”, El-Cezeri Journal of Science and Engineering, vol. 10, no. 3, pp. 538–553, Sept. 2023, doi: 10.31202/ecjse.1270783.
ISNAD
Srınıvasan, G - M, Lavanya. “Optimal Reactive Power Injection in Distribution Networks to Maximize Cost Savings Via AOA”. El-Cezeri 10/3 (September 1, 2023): 538-553. https://doi.org/10.31202/ecjse.1270783.
JAMA
1.Srınıvasan G, M L. Optimal Reactive Power Injection in Distribution Networks to Maximize Cost Savings Via AOA. El-Cezeri Journal of Science and Engineering. 2023;10:538–553.
MLA
Srınıvasan, G, and Lavanya M. “Optimal Reactive Power Injection in Distribution Networks to Maximize Cost Savings Via AOA”. El-Cezeri, vol. 10, no. 3, Sept. 2023, pp. 538-53, doi:10.31202/ecjse.1270783.
Vancouver
1.G Srınıvasan, Lavanya M. Optimal Reactive Power Injection in Distribution Networks to Maximize Cost Savings Via AOA. El-Cezeri Journal of Science and Engineering. 2023 Sep. 1;10(3):538-53. doi:10.31202/ecjse.1270783