Research Article
BibTex RIS Cite

THE THEORETICAL EVALUATION FOR THE USE OF VANADIUM (III) OXYHYDROXIDE FOR THE ELECTROCHEMICAL DETERMINATION OF BENZODIAZEPINES

Year 2018, Volume: 5 Issue: 2, 292 - 297, 31.05.2018
https://doi.org/10.31202/ecjse.370698

Abstract

The theoretical evaluation for the use of
vanadium (III) oxyhydroxide as an electrode modifier for benzodiazepines’
electrochemical determination in acid solutions has been made. The
correspondent mathematical model has been developed and analyzed by means of the
linear stability theory and bifurcation analysis. It was shown that VO(OH) may
be an efficient electrode modifier for the benzodiazepines electrochemical
determination in lightly and moderately acid solution. Its use in concentrated
acidic solution may be compromised by modifier destruction. The oscillatory
behavior in this system may be caused not only by the DEL influences of the
electrochemical stage, but also by surface instabilities, caused by VO(OH)
dissolution.

References

  • [1]. M. Gladis Mondino. Compostos Heterocíclicos. Estudo e Aplicações Sintéticas. 1ª Edição. São Paulo, Editora Atheneu, Série “Ciência e Tecnologia”, 2014, 224 pág.
  • [2]. T. Mehdi, Brit. J. Med. Pract., 5(2012), 501
  • [3]. J.D. Jones, S. Mogali, S. Corner, Drug. Alcohol. Depend., 2012, 125, 8
  • [4]. J.R. Bostwick, M.I. Casher, S. Yasugi, Curr. Psych., 2012, 11; Referência: http://www.currentpsychiatry.com/home/article/benzodiazepines-a-versatile-clinical-tool/f5f4e5bdf44396acbe205ca9dd87ccea.html accessed at the 3rd of December 2017
  • [5]. Sedative-hypnotic drugs. In: Basic and clinical pharmacology, 8th edition. Katzung BG. USA: The McGraw Hill Companies, Inc, 2001:364–381
  • [6]. J. Guina, S.R. Rossetter, B.J. de Rhodes et. al., J. Psychiatr. Pract., 21(2015), 281
  • [7]. B. Moosmann, L.M. Huppertz, M. Hutter et. al., J. Mass. Spectrom., 48(2013), 1150
  • [8]. L. J. Núñez-Vergara, S. Bollo, C. Olea-Azar et. al., J. Electroanal. Chem., 1997, 436, 227
  • [9]. M.E. Lozano-Chávez, J.M. Palacios-Santander, L. M. Cubillana-Aguilera et al., Sens. Act. B. Chem., 2006, 115, 575
  • [10]. M. N. Uddin, V.F. Samanidou, I.N. Papadoyannis, Pharm. Anal. Acta, 2014, 5, 303
  • [11] Y. Zhang, X. Jing, Mat. Lett., 205(2017), 1
  • [12]. Stadnik O. Synthesis, Electrochemical and Photoelectrochemical Properties of the Oxide-hydroxide Compounds of Cobalt, Diss. Kand. Chim. N. – Kyiv. – 2011
  • [13]. O. Stadnik, N. Ivanova, Y. Boldyrev, 218th Int. Electrochem. Soc. Meeting. Abstract # 2240, http://ma.ecsdl.org/content/MA201002 /38/2240.full.pdf Accessed at 8th of August 2015 [14]. V. Tkach, S.C. de Oliveira, R. Ojani et al., Rev. Colomb. Cien. Quím. Farm., 45(2016), 362
  • [15]. V.V. Tkach, Ya. G. Ivanushko, Iryna L. Kukovs´ka et al.,Revista Química Hoy, 6(2016), 14
  • [16]. V. Tkach, S.C. de Oliveira, G. Maia et. al., Mor. J. Chem., 4(2016), 112
  • [17]. V. Tkach, S.C. de Oliveira, F.J. Anaissi et. al., Anal. Bioanal. Electrochem., 8(2016), 1

The Theoretical Evaluation For The Use of Vanadium (Iii) Oxyhydroxide For The Electrochemical Determination of Benzodiazepines

Year 2018, Volume: 5 Issue: 2, 292 - 297, 31.05.2018
https://doi.org/10.31202/ecjse.370698

Abstract

The theoretical evaluation for the use of
vanadium (III) oxyhydroxide as an electrode modifier for benzodiazepines’
electrochemical determination in acid solutions has been made. The
correspondent mathematical model has been developed and analyzed by means of the
linear stability theory and bifurcation analysis. It was shown that VO(OH) may
be an efficient electrode modifier for the benzodiazepines electrochemical
determination in lightly and moderately acid solution. Its use in concentrated
acidic solution may be compromised by modifier destruction. The oscillatory
behavior in this system may be caused not only by the DEL influences of the
electrochemical stage, but also by surface instabilities, caused by VO(OH)
dissolution.

References

  • [1]. M. Gladis Mondino. Compostos Heterocíclicos. Estudo e Aplicações Sintéticas. 1ª Edição. São Paulo, Editora Atheneu, Série “Ciência e Tecnologia”, 2014, 224 pág.
  • [2]. T. Mehdi, Brit. J. Med. Pract., 5(2012), 501
  • [3]. J.D. Jones, S. Mogali, S. Corner, Drug. Alcohol. Depend., 2012, 125, 8
  • [4]. J.R. Bostwick, M.I. Casher, S. Yasugi, Curr. Psych., 2012, 11; Referência: http://www.currentpsychiatry.com/home/article/benzodiazepines-a-versatile-clinical-tool/f5f4e5bdf44396acbe205ca9dd87ccea.html accessed at the 3rd of December 2017
  • [5]. Sedative-hypnotic drugs. In: Basic and clinical pharmacology, 8th edition. Katzung BG. USA: The McGraw Hill Companies, Inc, 2001:364–381
  • [6]. J. Guina, S.R. Rossetter, B.J. de Rhodes et. al., J. Psychiatr. Pract., 21(2015), 281
  • [7]. B. Moosmann, L.M. Huppertz, M. Hutter et. al., J. Mass. Spectrom., 48(2013), 1150
  • [8]. L. J. Núñez-Vergara, S. Bollo, C. Olea-Azar et. al., J. Electroanal. Chem., 1997, 436, 227
  • [9]. M.E. Lozano-Chávez, J.M. Palacios-Santander, L. M. Cubillana-Aguilera et al., Sens. Act. B. Chem., 2006, 115, 575
  • [10]. M. N. Uddin, V.F. Samanidou, I.N. Papadoyannis, Pharm. Anal. Acta, 2014, 5, 303
  • [11] Y. Zhang, X. Jing, Mat. Lett., 205(2017), 1
  • [12]. Stadnik O. Synthesis, Electrochemical and Photoelectrochemical Properties of the Oxide-hydroxide Compounds of Cobalt, Diss. Kand. Chim. N. – Kyiv. – 2011
  • [13]. O. Stadnik, N. Ivanova, Y. Boldyrev, 218th Int. Electrochem. Soc. Meeting. Abstract # 2240, http://ma.ecsdl.org/content/MA201002 /38/2240.full.pdf Accessed at 8th of August 2015 [14]. V. Tkach, S.C. de Oliveira, R. Ojani et al., Rev. Colomb. Cien. Quím. Farm., 45(2016), 362
  • [15]. V.V. Tkach, Ya. G. Ivanushko, Iryna L. Kukovs´ka et al.,Revista Química Hoy, 6(2016), 14
  • [16]. V. Tkach, S.C. de Oliveira, G. Maia et. al., Mor. J. Chem., 4(2016), 112
  • [17]. V. Tkach, S.C. de Oliveira, F.J. Anaissi et. al., Anal. Bioanal. Electrochem., 8(2016), 1
There are 16 citations in total.

Details

Primary Language English
Subjects Engineering
Journal Section Makaleler
Authors

Volodymyr Tkach

Publication Date May 31, 2018
Submission Date December 25, 2017
Acceptance Date March 6, 2018
Published in Issue Year 2018 Volume: 5 Issue: 2

Cite

IEEE V. Tkach, “THE THEORETICAL EVALUATION FOR THE USE OF VANADIUM (III) OXYHYDROXIDE FOR THE ELECTROCHEMICAL DETERMINATION OF BENZODIAZEPINES”, ECJSE, vol. 5, no. 2, pp. 292–297, 2018, doi: 10.31202/ecjse.370698.