Araştırma Makalesi
BibTex RIS Kaynak Göster

THE THEORETICAL EVALUATION FOR THE USE OF VANADIUM (III) OXYHYDROXIDE FOR THE ELECTROCHEMICAL DETERMINATION OF BENZODIAZEPINES

Yıl 2018, Cilt: 5 Sayı: 2, 292 - 297, 31.05.2018
https://doi.org/10.31202/ecjse.370698

Öz

The theoretical evaluation for the use of
vanadium (III) oxyhydroxide as an electrode modifier for benzodiazepines’
electrochemical determination in acid solutions has been made. The
correspondent mathematical model has been developed and analyzed by means of the
linear stability theory and bifurcation analysis. It was shown that VO(OH) may
be an efficient electrode modifier for the benzodiazepines electrochemical
determination in lightly and moderately acid solution. Its use in concentrated
acidic solution may be compromised by modifier destruction. The oscillatory
behavior in this system may be caused not only by the DEL influences of the
electrochemical stage, but also by surface instabilities, caused by VO(OH)
dissolution.

Kaynakça

  • [1]. M. Gladis Mondino. Compostos Heterocíclicos. Estudo e Aplicações Sintéticas. 1ª Edição. São Paulo, Editora Atheneu, Série “Ciência e Tecnologia”, 2014, 224 pág.
  • [2]. T. Mehdi, Brit. J. Med. Pract., 5(2012), 501
  • [3]. J.D. Jones, S. Mogali, S. Corner, Drug. Alcohol. Depend., 2012, 125, 8
  • [4]. J.R. Bostwick, M.I. Casher, S. Yasugi, Curr. Psych., 2012, 11; Referência: http://www.currentpsychiatry.com/home/article/benzodiazepines-a-versatile-clinical-tool/f5f4e5bdf44396acbe205ca9dd87ccea.html accessed at the 3rd of December 2017
  • [5]. Sedative-hypnotic drugs. In: Basic and clinical pharmacology, 8th edition. Katzung BG. USA: The McGraw Hill Companies, Inc, 2001:364–381
  • [6]. J. Guina, S.R. Rossetter, B.J. de Rhodes et. al., J. Psychiatr. Pract., 21(2015), 281
  • [7]. B. Moosmann, L.M. Huppertz, M. Hutter et. al., J. Mass. Spectrom., 48(2013), 1150
  • [8]. L. J. Núñez-Vergara, S. Bollo, C. Olea-Azar et. al., J. Electroanal. Chem., 1997, 436, 227
  • [9]. M.E. Lozano-Chávez, J.M. Palacios-Santander, L. M. Cubillana-Aguilera et al., Sens. Act. B. Chem., 2006, 115, 575
  • [10]. M. N. Uddin, V.F. Samanidou, I.N. Papadoyannis, Pharm. Anal. Acta, 2014, 5, 303
  • [11] Y. Zhang, X. Jing, Mat. Lett., 205(2017), 1
  • [12]. Stadnik O. Synthesis, Electrochemical and Photoelectrochemical Properties of the Oxide-hydroxide Compounds of Cobalt, Diss. Kand. Chim. N. – Kyiv. – 2011
  • [13]. O. Stadnik, N. Ivanova, Y. Boldyrev, 218th Int. Electrochem. Soc. Meeting. Abstract # 2240, http://ma.ecsdl.org/content/MA201002 /38/2240.full.pdf Accessed at 8th of August 2015 [14]. V. Tkach, S.C. de Oliveira, R. Ojani et al., Rev. Colomb. Cien. Quím. Farm., 45(2016), 362
  • [15]. V.V. Tkach, Ya. G. Ivanushko, Iryna L. Kukovs´ka et al.,Revista Química Hoy, 6(2016), 14
  • [16]. V. Tkach, S.C. de Oliveira, G. Maia et. al., Mor. J. Chem., 4(2016), 112
  • [17]. V. Tkach, S.C. de Oliveira, F.J. Anaissi et. al., Anal. Bioanal. Electrochem., 8(2016), 1

The Theoretical Evaluation For The Use of Vanadium (Iii) Oxyhydroxide For The Electrochemical Determination of Benzodiazepines

Yıl 2018, Cilt: 5 Sayı: 2, 292 - 297, 31.05.2018
https://doi.org/10.31202/ecjse.370698

Öz

The theoretical evaluation for the use of
vanadium (III) oxyhydroxide as an electrode modifier for benzodiazepines’
electrochemical determination in acid solutions has been made. The
correspondent mathematical model has been developed and analyzed by means of the
linear stability theory and bifurcation analysis. It was shown that VO(OH) may
be an efficient electrode modifier for the benzodiazepines electrochemical
determination in lightly and moderately acid solution. Its use in concentrated
acidic solution may be compromised by modifier destruction. The oscillatory
behavior in this system may be caused not only by the DEL influences of the
electrochemical stage, but also by surface instabilities, caused by VO(OH)
dissolution.

Kaynakça

  • [1]. M. Gladis Mondino. Compostos Heterocíclicos. Estudo e Aplicações Sintéticas. 1ª Edição. São Paulo, Editora Atheneu, Série “Ciência e Tecnologia”, 2014, 224 pág.
  • [2]. T. Mehdi, Brit. J. Med. Pract., 5(2012), 501
  • [3]. J.D. Jones, S. Mogali, S. Corner, Drug. Alcohol. Depend., 2012, 125, 8
  • [4]. J.R. Bostwick, M.I. Casher, S. Yasugi, Curr. Psych., 2012, 11; Referência: http://www.currentpsychiatry.com/home/article/benzodiazepines-a-versatile-clinical-tool/f5f4e5bdf44396acbe205ca9dd87ccea.html accessed at the 3rd of December 2017
  • [5]. Sedative-hypnotic drugs. In: Basic and clinical pharmacology, 8th edition. Katzung BG. USA: The McGraw Hill Companies, Inc, 2001:364–381
  • [6]. J. Guina, S.R. Rossetter, B.J. de Rhodes et. al., J. Psychiatr. Pract., 21(2015), 281
  • [7]. B. Moosmann, L.M. Huppertz, M. Hutter et. al., J. Mass. Spectrom., 48(2013), 1150
  • [8]. L. J. Núñez-Vergara, S. Bollo, C. Olea-Azar et. al., J. Electroanal. Chem., 1997, 436, 227
  • [9]. M.E. Lozano-Chávez, J.M. Palacios-Santander, L. M. Cubillana-Aguilera et al., Sens. Act. B. Chem., 2006, 115, 575
  • [10]. M. N. Uddin, V.F. Samanidou, I.N. Papadoyannis, Pharm. Anal. Acta, 2014, 5, 303
  • [11] Y. Zhang, X. Jing, Mat. Lett., 205(2017), 1
  • [12]. Stadnik O. Synthesis, Electrochemical and Photoelectrochemical Properties of the Oxide-hydroxide Compounds of Cobalt, Diss. Kand. Chim. N. – Kyiv. – 2011
  • [13]. O. Stadnik, N. Ivanova, Y. Boldyrev, 218th Int. Electrochem. Soc. Meeting. Abstract # 2240, http://ma.ecsdl.org/content/MA201002 /38/2240.full.pdf Accessed at 8th of August 2015 [14]. V. Tkach, S.C. de Oliveira, R. Ojani et al., Rev. Colomb. Cien. Quím. Farm., 45(2016), 362
  • [15]. V.V. Tkach, Ya. G. Ivanushko, Iryna L. Kukovs´ka et al.,Revista Química Hoy, 6(2016), 14
  • [16]. V. Tkach, S.C. de Oliveira, G. Maia et. al., Mor. J. Chem., 4(2016), 112
  • [17]. V. Tkach, S.C. de Oliveira, F.J. Anaissi et. al., Anal. Bioanal. Electrochem., 8(2016), 1
Toplam 16 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Konular Mühendislik
Bölüm Makaleler
Yazarlar

Volodymyr Tkach

Yayımlanma Tarihi 31 Mayıs 2018
Gönderilme Tarihi 25 Aralık 2017
Kabul Tarihi 6 Mart 2018
Yayımlandığı Sayı Yıl 2018 Cilt: 5 Sayı: 2

Kaynak Göster

IEEE V. Tkach, “THE THEORETICAL EVALUATION FOR THE USE OF VANADIUM (III) OXYHYDROXIDE FOR THE ELECTROCHEMICAL DETERMINATION OF BENZODIAZEPINES”, ECJSE, c. 5, sy. 2, ss. 292–297, 2018, doi: 10.31202/ecjse.370698.