A Novel Method for Partial Demagnetization Fault Detection in PMSMs
Abstract
It is
generally very important to detect partial demagnetization faults at the
beginning stage for Permanent Magnet Synchronous Motors (PMSMs) which are
generally operated under nonstationary conditions in industrial applications.
In this study, a new method based on Gabor Order Tracking (GOT) has been
presented which tracks the orders that are characteristic of the fault in motor
current at nonstationary operating speeds for the detection of partial
demagnetization fault. The amplitude changes of the envelope signal obtained
from the order components were used as fault indicators. The results obtained
from the experimental study indicate that the suggested method successfully
detects the partial demagnetization fault under different speed and load
conditions. The main innovative parts of this study are that GOT method was
implemented on the motor current signal for the first time.
Keywords
References
- Akar, M. and Eker, M., 2013. Demagnetization fault diagnosis in permanent magnet synchronous motors. Przeglad Elektrotechniczny. 2013 (2a): 229-233.
- Anonymous, 2016; http://www.ni.com/white-paper/4686/en/
- Espinosa, A.G., Rosero, J.A., Cusido, J., Romeral, L. and Ortega, J.A., 2010. Fault detection by means of Hilbert–Huang Transform of the stator current in a PMSM with demagnetization. IEEE Transactions Energy Conversions. 25 (2):312–318.
- Gade, S., Herlufsen, H., Konstantin-Hansen, H. and Wismer, N.J., 1995. Order tracking analysis. Brüel and Kjær Technical Review. 2.
- Gade, S., Herlufsen, H., Konstantin-Hansen, H. and Vold, H., 1999. Characteristics of the Vold-Kalman order tracking filter. Brüel and Kjær Technical Review. 1.
- HUR, J., 2008. Characteristic analysis of interior permanent magnet synchronous motor in electrohydraulic power steering systems. IEEE Transactions on Industrial Electronics. 55 (6): 2316–2323.
- Ishikawa, T., Seki, Y. and Kurita, N., 2013. Analysis for fault detection of vector-controlled permanent magnet synchronous motor with permanent magnet defect. IEEE Transactions on Magnetics. 49 (5): 2331–2334.
- Jin, Y. and Hao, Z., 2010. An improved flowchart for Gabor Order Tracking with Gaussian Window as the analysis window. EUROSIP Journal on Advances in Signal Processing. 2011 (507215): 1-9.
Details
Primary Language
Turkish
Subjects
Engineering
Journal Section
Research Article
Authors
Mustafa Eker
Gaziosmanpaşa Üniveristesi
Türkiye
Mehmet Akar
Türkiye
Cem Emeksiz
Türkiye
Zafer Doğan
Türkiye
Publication Date
August 31, 2017
Submission Date
June 1, 2017
Acceptance Date
August 3, 2017
Published in Issue
Year 2017 Volume: 6 Number: 2