Plasma Modified Foley Catheters Against to Catheter Associated Urinary Tract Infection CAUTI

Volume: 36 Number: 1 January 1, 2008
  • Gökhan Erdoğan
  • Emir Baki Denkbaş
  • Eylem Öztürk
  • Canan Ağalar
  • Muzeffer Eroğlu
  • Pelin Atilla

Plasma Modified Foley Catheters Against to Catheter Associated Urinary Tract Infection CAUTI

Abstract

In this study; the foley catheters were modified by plasma polymerization technique and coated with alginate gels. Thismodification processes were applied to prevent bacterial adhesion onto the foley catheter surfaces. Here the mosteffective parameters were evaluated as the plasma polymerization system power and plasma exposure time for theeffective catheter surface modification. The obtained results showed that the plasma power affected hidrophilicity ofthe surface and wettability of the foley catheters was increased. The plasma exposure time increased the amount ofEDA deposition over the catheter surfaces and then caused more hydrophilicity for the foley catheter surfaces also.In this study, the bacterial strain ofE. Coli had a hydrophobic nature and therefore the increase in hydrophilicity ofthe surface of foley catheters decreased the adhesion risk for theE. Coli onto the catheter surfaces. As the numericalvalues of the obtained data; while the amount of bacterial colony formation unit was at 108 level initially, it wasdecreased down to 104-103level by changing the surface hydrophilicities as expected

Keywords

References

  1. 1. Riedl C.R., Witkowski M., Plas E., Pflueger H., Heparin coating reduces encrustation of ureteral stents: a preliminary report, International Journal of Antimicrobial Agents, 19 (2002) 507.
  2. 2. Schierholz J.M., Yücel N., Rump A.F.E., Beuth J, Pulverer G., Antiinfective and encrustation-inhibiting materials/myth and facts, International Journal of Antimicrobial Agents, 19 (2002) 511.
  3. 3. Reid G., Davidson R., Denstedt D. XPS, SEM and EDX analysis of conditioning lm deposition onto ureteral stents, Surf Interface Anal, 21 (1994) 58.
  4. 5. Santin M., Motta A., Denyer S.P., Cannas M., Effect of the urine conditioning film on ureteral stent encrustation and characterization of its protein composition, Biomaterials, 20 (1999) 1245.
  5. 6. Elves AWS, Feneley RCL. Long-term urethral catheterization and the urine biomaterial interface, Br J Urol, 80 (1997) 1.
  6. 7. Schierholz JM, Beuth J. Sophisticated medical devices as local drug delivery systems, Med Dev Tech, 11(2) (2000) 12.
  7. 8. Schierholz JM, Beuth J. Implant infections haven for opportunistic bacteria, J Hosp Inf, 49 ( 2001) 87.
  8. 9. DiTizio V., Ferguson G.W., Mittelman M.W., Khoury A.E., Bruce A.W., DiCosmo F., A liposomal hydrogel for the prevention of bacterial adhesion to catheters, Biomaterials, 19 (1998) 1877.

Details

Primary Language

English

Subjects

-

Journal Section

-

Authors

Gökhan Erdoğan This is me

Emir Baki Denkbaş This is me

Eylem Öztürk This is me

Canan Ağalar This is me

Muzeffer Eroğlu This is me

Pelin Atilla This is me

Publication Date

January 1, 2008

Submission Date

-

Acceptance Date

-

Published in Issue

Year 2008 Volume: 36 Number: 1

APA
Erdoğan, G., Denkbaş, E. B., Öztürk, E., Ağalar, C., Eroğlu, M., & Atilla, P. (2008). Plasma Modified Foley Catheters Against to Catheter Associated Urinary Tract Infection CAUTI. Hacettepe Journal of Biology and Chemistry, 36(1), 1-8. https://izlik.org/JA24CF56US
AMA
1.Erdoğan G, Denkbaş EB, Öztürk E, Ağalar C, Eroğlu M, Atilla P. Plasma Modified Foley Catheters Against to Catheter Associated Urinary Tract Infection CAUTI. HJBC. 2008;36(1):1-8. https://izlik.org/JA24CF56US
Chicago
Erdoğan, Gökhan, Emir Baki Denkbaş, Eylem Öztürk, Canan Ağalar, Muzeffer Eroğlu, and Pelin Atilla. 2008. “Plasma Modified Foley Catheters Against to Catheter Associated Urinary Tract Infection CAUTI”. Hacettepe Journal of Biology and Chemistry 36 (1): 1-8. https://izlik.org/JA24CF56US.
EndNote
Erdoğan G, Denkbaş EB, Öztürk E, Ağalar C, Eroğlu M, Atilla P (January 1, 2008) Plasma Modified Foley Catheters Against to Catheter Associated Urinary Tract Infection CAUTI. Hacettepe Journal of Biology and Chemistry 36 1 1–8.
IEEE
[1]G. Erdoğan, E. B. Denkbaş, E. Öztürk, C. Ağalar, M. Eroğlu, and P. Atilla, “Plasma Modified Foley Catheters Against to Catheter Associated Urinary Tract Infection CAUTI”, HJBC, vol. 36, no. 1, pp. 1–8, Jan. 2008, [Online]. Available: https://izlik.org/JA24CF56US
ISNAD
Erdoğan, Gökhan - Denkbaş, Emir Baki - Öztürk, Eylem - Ağalar, Canan - Eroğlu, Muzeffer - Atilla, Pelin. “Plasma Modified Foley Catheters Against to Catheter Associated Urinary Tract Infection CAUTI”. Hacettepe Journal of Biology and Chemistry 36/1 (January 1, 2008): 1-8. https://izlik.org/JA24CF56US.
JAMA
1.Erdoğan G, Denkbaş EB, Öztürk E, Ağalar C, Eroğlu M, Atilla P. Plasma Modified Foley Catheters Against to Catheter Associated Urinary Tract Infection CAUTI. HJBC. 2008;36:1–8.
MLA
Erdoğan, Gökhan, et al. “Plasma Modified Foley Catheters Against to Catheter Associated Urinary Tract Infection CAUTI”. Hacettepe Journal of Biology and Chemistry, vol. 36, no. 1, Jan. 2008, pp. 1-8, https://izlik.org/JA24CF56US.
Vancouver
1.Gökhan Erdoğan, Emir Baki Denkbaş, Eylem Öztürk, Canan Ağalar, Muzeffer Eroğlu, Pelin Atilla. Plasma Modified Foley Catheters Against to Catheter Associated Urinary Tract Infection CAUTI. HJBC [Internet]. 2008 Jan. 1;36(1):1-8. Available from: https://izlik.org/JA24CF56US

HACETTEPE JOURNAL OF BIOLOGY AND CHEMİSTRY

Copyright © Hacettepe University Faculty of Science

http://www.hjbc.hacettepe.edu.tr/

https://dergipark.org.tr/tr/pub/hjbc