Investigation of the Human Maxilla and Mandible Trabecular Microstructure with Micro-Computed Tomography

Volume: 20 Number: 1 April 27, 2023
EN TR

Investigation of the Human Maxilla and Mandible Trabecular Microstructure with Micro-Computed Tomography

Abstract

ÖZ Amaç: Maksilla ve mandibulanın trabeküler mikromimarisini mikrobilgisayarlı tomografi (mikro-BT) kullanarak değerlendirmek. Materyal ve metod: Yirmi adet maksiller ve mandibula kadavra örneği, mikro BT kullanılarak tarandı. Numuneler Skyscan 1275® micro-CT sistemi (SkyScan, Kontich, Belçika) kullanılarak aşağıdaki parametrelerle tarandı. Tarama verileri CTan yazılımına aktarıldı ve analiz edildi. Morfometrik parametreler; doku hacmi (DH), Kemik hacmi (KH), kemik hacmi yüzdesi (KH/DH), doku yüzeyi (DY), kemik yüzeyi (KY), kesişme yüzeyi (KY), kemik yüzeyi/hacim oranı (KY/KH), kemik yüzey yoğunluğu (BS/TV), trabeküler patern faktörü (Tb.Pf), yapı modeli indeksi (YMI), trabeküler kalınlık (Tb. Th), trabeküler ayrılma (Tb. Sp), trabeküler sayı (Tb.N) ve anizotropi derecesi (DA), CTAnalyzer yazılımı kullanılarak değerlendirildi. İstatistiksel anlamlılık p<0.05 olarak ayarlandı. Bulgular: BV/TV, Tb.Th, Tb. KIBT görüntülerinde Sp ve DA değerleri mikro-BT görüntülerine göre daha yüksek iken, Tb. CBCT görüntülerinde N değeri, mikro BT görüntülerinden daha düşüktü. BV/TV ve DA parametreleri, CBCT ve mikro-CT cihazları arasında en yüksek uyumu gösterdi (BV/TV için ICC=0,421 ve DA için ICC=0,439, p<0,01). Sonuç: En küçük voksel boyutunda elde edilen CBCT'de ölçülen BV/TV ve DA parametrelerinin maksiller trabeküler mikroyapının değerlendirilmesinde yararlı olduğu bulundu. Anahtar Kelimeler: Mikro bilgisayarlı tomografi, trabeküler kemik mikro yapısı, Maxilla, Mandibula.

Keywords

References

  1. 1. Lakatos E, Magyar L, Bojtár I, Material Properties of the Mandibular Trabecular Bone. Journal of Medical Enginee-ring 2014 Article ID 470539 http://dx.doi.org/10.1155/2014/470539
  2. 2. Nkenke E, Hahn M, Weinzierl K, Radespiel-Tröger M, Wil-helm Neukam F, Engelke K. Implant stability and histo-morphometry: a correlation study in human cadavers using stepped cylinder implants, Clin Oral Implants Res; 2003;14(5):601-9.
  3. 3. Miyamoto I, Tsuboi Y, Wada E, Suwa H, Tadahiko Iizuka T. Influence of cortical bone thickness and implant length on implant stability at the time of surgery--clinical, prospecti-ve, biomechanical, and imaging study. Bone. 2005;37( 6): 776-780.
  4. 4. Heinemann F, Hasan I, Bourauel C, Biffar R, Mundt T. Bone stability around dental implants: Treatment related factors. 2015, 199;3-8.
  5. 5. Javed F, Romanos GE. The role of primary stability for suc-cessful immediate loading of dental implants. A literature review. J Dent 2010;38:612-20
  6. 6. Sennerby L, Meredith N. Implant stability measurements using resonance frequency analysis: biological and biomec-hanical aspects and clinical implications. Periodontol 2008; 47:51–66.
  7. 7. Açıkgöz A. K, Morphometric Evaluation, Locational Relati-onship, and Surgical Significance of the Maxillofacial Region Landmarks, ınternatıonal journal of morphology. 2021; 39: 5: 1289-1295.
  8. 8. Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont 1998;11:491-501.

Details

Primary Language

English

Subjects

Clinical Sciences

Journal Section

Research Article

Early Pub Date

April 27, 2023

Publication Date

April 27, 2023

Submission Date

February 19, 2023

Acceptance Date

March 20, 2023

Published in Issue

Year 2023 Volume: 20 Number: 1

APA
Soysal, H., Geneci, F., & Ocak, M. (2023). Investigation of the Human Maxilla and Mandible Trabecular Microstructure with Micro-Computed Tomography. Harran Üniversitesi Tıp Fakültesi Dergisi, 20(1), 67-73. https://doi.org/10.35440/hutfd.1253254
AMA
1.Soysal H, Geneci F, Ocak M. Investigation of the Human Maxilla and Mandible Trabecular Microstructure with Micro-Computed Tomography. Harran Üniversitesi Tıp Fakültesi Dergisi. 2023;20(1):67-73. doi:10.35440/hutfd.1253254
Chicago
Soysal, Handan, Ferhat Geneci, and Mert Ocak. 2023. “Investigation of the Human Maxilla and Mandible Trabecular Microstructure With Micro-Computed Tomography”. Harran Üniversitesi Tıp Fakültesi Dergisi 20 (1): 67-73. https://doi.org/10.35440/hutfd.1253254.
EndNote
Soysal H, Geneci F, Ocak M (April 1, 2023) Investigation of the Human Maxilla and Mandible Trabecular Microstructure with Micro-Computed Tomography. Harran Üniversitesi Tıp Fakültesi Dergisi 20 1 67–73.
IEEE
[1]H. Soysal, F. Geneci, and M. Ocak, “Investigation of the Human Maxilla and Mandible Trabecular Microstructure with Micro-Computed Tomography”, Harran Üniversitesi Tıp Fakültesi Dergisi, vol. 20, no. 1, pp. 67–73, Apr. 2023, doi: 10.35440/hutfd.1253254.
ISNAD
Soysal, Handan - Geneci, Ferhat - Ocak, Mert. “Investigation of the Human Maxilla and Mandible Trabecular Microstructure With Micro-Computed Tomography”. Harran Üniversitesi Tıp Fakültesi Dergisi 20/1 (April 1, 2023): 67-73. https://doi.org/10.35440/hutfd.1253254.
JAMA
1.Soysal H, Geneci F, Ocak M. Investigation of the Human Maxilla and Mandible Trabecular Microstructure with Micro-Computed Tomography. Harran Üniversitesi Tıp Fakültesi Dergisi. 2023;20:67–73.
MLA
Soysal, Handan, et al. “Investigation of the Human Maxilla and Mandible Trabecular Microstructure With Micro-Computed Tomography”. Harran Üniversitesi Tıp Fakültesi Dergisi, vol. 20, no. 1, Apr. 2023, pp. 67-73, doi:10.35440/hutfd.1253254.
Vancouver
1.Handan Soysal, Ferhat Geneci, Mert Ocak. Investigation of the Human Maxilla and Mandible Trabecular Microstructure with Micro-Computed Tomography. Harran Üniversitesi Tıp Fakültesi Dergisi. 2023 Apr. 1;20(1):67-73. doi:10.35440/hutfd.1253254

Cited By

Articles published in this journal are licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License (CC-BY-NC-SA 4.0).