Research Article

Investigation of the performance of ground-coupled heat exchanger technology for tempering air

Volume: 6 Number: 2 June 30, 2022
  • Mahendra Gooroochurn *
  • Maheshsingh Mungur
  • Heman Shamachurn
  • Yashwansingh Surnam
  • Fardeen Mandarkhan
  • Devin Bhoodoo
EN

Investigation of the performance of ground-coupled heat exchanger technology for tempering air

Abstract

A horizontal ground heat exchanger has been applied as a simpler sustainability measure in buildings compared to its vertical counterpart, making it more suitable for residential application. A lack of contextual scientific findings within the specific construction culture has precluded its widespread application in the developing world. In this study, an experimental and simulation investigation was carried out on the thermal performance of an air-based horizontal ground-coupled heat exchanger buried 3 m below the ground. The study was performed in the tropical climate of Mauritius with a focus on space cooling. The ground temperature and air temperature inside the pipeline at several locations of the installation was measured. A CFD simulation model was developed and calibrated against the experimental data, which allowed further analyses on the influence of system parameters on performance. The study allowed to confirm the performance of the technology for application as a sustainability measure in the local construction industry and to identify practical challenge that need to be addressed. A drop in temperature of up to 5C was achieved at 2.3 m/s and 8C at 4 m/s. The latter result holds promise to achieve thermal comfort by achieving indoor air temperature of 27 C or lower when ambient air is at 33-34C during typical summer periods.

Keywords

Supporting Institution

Higher Education Commission

Project Number

TEC/11/4/3/2018

Thanks

The authors wish to express their humble gratitude to the Higher Education Commission, Mauritius for funding the research work.

References

  1. [1] Lund, J., Freeston, D. World-wide direct uses of geothermal energy 2000. Geothermics 2001; 30 (1): 29-68.
  2. [2] Lund, J. GEOTHERMAL HEAT PUMPS - TRENDS AND COMPARISONS - Geo-Heat Center.
  3. [3] Im, P, Hughes, P, Liu, X, Ridge, O. Demonstration and performance monitoring of foundation heat exchangers (FHX) in ultra-high energy efficient research Homes Field test of the foundation heat exchanger concept. In: 17th ACEEE Summer Study on Energy Efficiency in Buildings; 12-17 August 2012: Pacific Grove, CA, pp. 114-126
  4. [4] Xu, H, Spitler, JD. The relative importance of moisture transfer, soil freezing and snow cover on ground temperature predictions. Renewable Energy 2014; 72: 1-11.
  5. [5] Busby, J. Determination of thermal properties for horizontal ground collector loops. In: Proceedings of World Geothermal Congress 2015; 19-25 April 2015: Melbourne, Australia, pp. 19-25.
  6. [6] Naylor, S, Ellett, KM, Gustin, AR. Spatiotemporal variability of ground thermal properties in glacial sediments and implications for horizontal ground heat exchanger design. Renewable Energy 2015; 81: 21-30.
  7. [7] King, W, Banks, D, Findlay, J. Field determination of shallow soil thermal conductivity using a short-duration needle probe test. Quarterly Journal of Engineering Geology and Hydrogeology 2012; 45 (4): 497-504.
  8. [8] Gan, G. Dynamic thermal performance of horizontal ground source heat pumps – The impact of coupled heat and moisture transfer. Energy 2018; 152: 877-887.

Details

Primary Language

English

Subjects

-

Journal Section

Research Article

Authors

Maheshsingh Mungur This is me
0000-0002-6590-7872
Mauritius

Heman Shamachurn This is me
0000-0003-3441-1054
Mauritius

Yashwansingh Surnam This is me
0000-0002-3941-8135
Mauritius

Fardeen Mandarkhan This is me
0000-0001-9169-1123
Mauritius

Devin Bhoodoo This is me
0000-0001-9179-9505
Mauritius

Publication Date

June 30, 2022

Submission Date

January 17, 2022

Acceptance Date

April 22, 2022

Published in Issue

Year 2022 Volume: 6 Number: 2

APA
Gooroochurn, M., Mungur, M., Shamachurn, H., Surnam, Y., Mandarkhan, F., & Bhoodoo, D. (2022). Investigation of the performance of ground-coupled heat exchanger technology for tempering air. Journal of Energy Systems, 6(2), 309-321. https://doi.org/10.30521/jes.1058233
AMA
1.Gooroochurn M, Mungur M, Shamachurn H, Surnam Y, Mandarkhan F, Bhoodoo D. Investigation of the performance of ground-coupled heat exchanger technology for tempering air. Journal of Energy Systems. 2022;6(2):309-321. doi:10.30521/jes.1058233
Chicago
Gooroochurn, Mahendra, Maheshsingh Mungur, Heman Shamachurn, Yashwansingh Surnam, Fardeen Mandarkhan, and Devin Bhoodoo. 2022. “Investigation of the Performance of Ground-Coupled Heat Exchanger Technology for Tempering Air”. Journal of Energy Systems 6 (2): 309-21. https://doi.org/10.30521/jes.1058233.
EndNote
Gooroochurn M, Mungur M, Shamachurn H, Surnam Y, Mandarkhan F, Bhoodoo D (June 1, 2022) Investigation of the performance of ground-coupled heat exchanger technology for tempering air. Journal of Energy Systems 6 2 309–321.
IEEE
[1]M. Gooroochurn, M. Mungur, H. Shamachurn, Y. Surnam, F. Mandarkhan, and D. Bhoodoo, “Investigation of the performance of ground-coupled heat exchanger technology for tempering air”, Journal of Energy Systems, vol. 6, no. 2, pp. 309–321, June 2022, doi: 10.30521/jes.1058233.
ISNAD
Gooroochurn, Mahendra - Mungur, Maheshsingh - Shamachurn, Heman - Surnam, Yashwansingh - Mandarkhan, Fardeen - Bhoodoo, Devin. “Investigation of the Performance of Ground-Coupled Heat Exchanger Technology for Tempering Air”. Journal of Energy Systems 6/2 (June 1, 2022): 309-321. https://doi.org/10.30521/jes.1058233.
JAMA
1.Gooroochurn M, Mungur M, Shamachurn H, Surnam Y, Mandarkhan F, Bhoodoo D. Investigation of the performance of ground-coupled heat exchanger technology for tempering air. Journal of Energy Systems. 2022;6:309–321.
MLA
Gooroochurn, Mahendra, et al. “Investigation of the Performance of Ground-Coupled Heat Exchanger Technology for Tempering Air”. Journal of Energy Systems, vol. 6, no. 2, June 2022, pp. 309-21, doi:10.30521/jes.1058233.
Vancouver
1.Mahendra Gooroochurn, Maheshsingh Mungur, Heman Shamachurn, Yashwansingh Surnam, Fardeen Mandarkhan, Devin Bhoodoo. Investigation of the performance of ground-coupled heat exchanger technology for tempering air. Journal of Energy Systems. 2022 Jun. 1;6(2):309-21. doi:10.30521/jes.1058233

Cited By

Journal of Energy Systems is licensed under CC BY-NC 4.0