Report

COMPARISON OF SHORT DENTAL IMPLANTS UNDER DIFFERENT LOADING CONDITIONS AND LOCATIONS

Volume: 2 Number: 3 December 30, 2014
  • Emre Ozyılmaz
  • Halil Aykul
  • Eda Ozyılmaz
  • Mehmet Dalkız
EN TR

COMPARISON OF SHORT DENTAL IMPLANTS UNDER DIFFERENT LOADING CONDITIONS AND LOCATIONS

Abstract

Dental implant restoration has been widely accepted as one of the treatment modalities to replace missing teeth and to restore human masticatory function. The finite element method (FEM) has been a useful tool in studying the bone-to-implant interface under mechanical loading. The use of short dental implants are increased thanks to its advantages according to long dental implants when the quality of bone is lower. The aim of this study was to analyse the effects of implant diameter, length and loading conditions on short dental implants. A three dimensional (3D) model of short dental implants were made with different sizes and types. Dental implant designs were performed on Solidworks 2013. The mandible model is obtained from Computed Tomography then transferred to 3D model. Finite Element analysis is done by applying material properties, contact properties, physiological loading and boundary conditions with the use of Ansys Workbench

Keywords

References

  1. Baggi. L.. Cappelloni, I., Girolamo, M.D., Maceri, F., Vairo, G., 2008. The Influence of Implant Diameter and Length on Stress Distribution of Osseointegrated Implants Related to Crestal Bone Geometry: a Three Dimensional Finite Element Analysis. J Prosthet Dent; 100:422–31.
  2. Binon, P.P., Sutter, F., Beaty, K., Brusnki, J., Gulbransen, H., Weiner, R., 1994. The Role of Screws in Implant Systems.
  3. 9(Supplement): 48–63. Maxillofac
  4. Implants; Brunski, J. B., 1997. “Biomechanics of Dental Implants.” in Implants in Dentistry, pp, 63–71.
  5. Brunski, J.B., Puleo, D.A., Nanci, A., 2000. “Biomaterials and Biomechanics of Oral and Maxillofacial Implants: Current
  6. International Journal of Oral and Maxillofacial Implants. Vo, 15. no. 1. pp. 15–46.
  7. Developments.” Celik, G., Uludag, B., 2007. Photoelastic Stress Analysis of Various Retention Mechanisms on 3-implant- retained Mandibular Overdentures. J Prosthet Dent; 97:229–35.
  8. Friberg, B., Grondahl, K., Lekholm, U., Branemark, P.I., 2000. Long-term Follow-up of Severely Atrophic Edentulous Mandibles Reconstructed with Short Branemark implants. Clin Implant Dent Relat Res; 2:184–9.

Details

Primary Language

English

Subjects

Engineering

Journal Section

Report

Authors

Emre Ozyılmaz This is me

Halil Aykul This is me

Eda Ozyılmaz This is me

Mehmet Dalkız This is me

Publication Date

December 30, 2014

Submission Date

January 1, 2015

Acceptance Date

-

Published in Issue

Year 2014 Volume: 2 Number: 3

APA
Ozyılmaz, E., Aykul, H., Ozyılmaz, E., & Dalkız, M. (2014). COMPARISON OF SHORT DENTAL IMPLANTS UNDER DIFFERENT LOADING CONDITIONS AND LOCATIONS. Mühendislik Bilimleri Ve Tasarım Dergisi, 2(3), 261-265. https://izlik.org/JA34HH36KR
AMA
1.Ozyılmaz E, Aykul H, Ozyılmaz E, Dalkız M. COMPARISON OF SHORT DENTAL IMPLANTS UNDER DIFFERENT LOADING CONDITIONS AND LOCATIONS. JESD. 2014;2(3):261-265. https://izlik.org/JA34HH36KR
Chicago
Ozyılmaz, Emre, Halil Aykul, Eda Ozyılmaz, and Mehmet Dalkız. 2014. “COMPARISON OF SHORT DENTAL IMPLANTS UNDER DIFFERENT LOADING CONDITIONS AND LOCATIONS”. Mühendislik Bilimleri Ve Tasarım Dergisi 2 (3): 261-65. https://izlik.org/JA34HH36KR.
EndNote
Ozyılmaz E, Aykul H, Ozyılmaz E, Dalkız M (December 1, 2014) COMPARISON OF SHORT DENTAL IMPLANTS UNDER DIFFERENT LOADING CONDITIONS AND LOCATIONS. Mühendislik Bilimleri ve Tasarım Dergisi 2 3 261–265.
IEEE
[1]E. Ozyılmaz, H. Aykul, E. Ozyılmaz, and M. Dalkız, “COMPARISON OF SHORT DENTAL IMPLANTS UNDER DIFFERENT LOADING CONDITIONS AND LOCATIONS”, JESD, vol. 2, no. 3, pp. 261–265, Dec. 2014, [Online]. Available: https://izlik.org/JA34HH36KR
ISNAD
Ozyılmaz, Emre - Aykul, Halil - Ozyılmaz, Eda - Dalkız, Mehmet. “COMPARISON OF SHORT DENTAL IMPLANTS UNDER DIFFERENT LOADING CONDITIONS AND LOCATIONS”. Mühendislik Bilimleri ve Tasarım Dergisi 2/3 (December 1, 2014): 261-265. https://izlik.org/JA34HH36KR.
JAMA
1.Ozyılmaz E, Aykul H, Ozyılmaz E, Dalkız M. COMPARISON OF SHORT DENTAL IMPLANTS UNDER DIFFERENT LOADING CONDITIONS AND LOCATIONS. JESD. 2014;2:261–265.
MLA
Ozyılmaz, Emre, et al. “COMPARISON OF SHORT DENTAL IMPLANTS UNDER DIFFERENT LOADING CONDITIONS AND LOCATIONS”. Mühendislik Bilimleri Ve Tasarım Dergisi, vol. 2, no. 3, Dec. 2014, pp. 261-5, https://izlik.org/JA34HH36KR.
Vancouver