Research Article

Development of an ultra-sensitive method using nafion and multi-walled carbon nanotube coated glassy carbon electrode for atenolol determination

Volume: 24 Number: 7 December 28, 2018
TR EN

Development of an ultra-sensitive method using nafion and multi-walled carbon nanotube coated glassy carbon electrode for atenolol determination

Abstract

Atenolol (Scheme 1) is antihypertensive drug that form β-blocker group, which widely used in the treatment of hypertension In this study, the redox properties of the Tensinor drug used in blood pressure treatment were examined on modified glassy carbon electrode and the electrodes prepared by coating carbon nanotubes on this modified electrode. In order to investigate the effects of nafion coated multi-walled glass nanotube (MWCNT / NGCE) electrode response and nafion coated glassy carbon electrode (NGCE) and electrode responses of only glassy carbon electrode (GCE) surfaces on the support electrolyte, pH and scan rate, the cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods were used. Atenolol (ATN) was observed in the Britton-Robinson (BR) buffer solution (pH 7.0) thereabouts 1.11 V (vsAg / AgCl (3.0 mol L-1 KCl). Voltammetric method reacted linear at a concentration range between 3x10-5 μM and 9x10-2 μM under optimum analytical experimental conditions. The results of Tensinor's limit of detection on the Britton-Robinson (BR) (pH=7) buffer were found to be 7.67 x 10-5 mM and 2.5 x 10-4 mM, respectively. Additionally, in the study, interference effects experiments were performed with auxiliary substances used in the preparation of medicines and no negative effect was observed.

Keywords

References

  1. Sudha T, Krishana KV, Nukala PCS, Saloman RT, Ganesan V. “Method development and validation”. Journal of Advanced Pharmacy Education & Research, 2(3), 146-176, 2012.
  2. Wang J. Analytical Electrochemistry, New Jersey, USA,Wiley-VCH Pub. 2006.
  3. Gupta, VK, Jain R, Radhapyari K, Jadon N, Agarwal S. “Voltammetric techniques for the assay of pharmaceuticals”. Analytical Biochemistry, 408(2), 179-196, 2011.
  4. Andrieux CP, Audebert P, Divisia-Blohorn B, Aldebert P, Michalak F. “Electrochemistry in Hydrophobic Nafion Gels”. Journal of Electroanalytical Chemistry, 296(1), 117-139, 1990.
  5. Svancara I, Vytras K, Kalcher K, Walcarius A, Wang J. “Carbon paste electrodes in facts, numbers, and notes: a review on the occasion of the 50-years jubilee of carbon paste in electrochemistry and electroanalysis”. Electroanalysis, 21(1), 7-28, 2009.
  6. Guo S, Wu X, Zhou J, Wang J, Yang B, Ye B. “MWNT/Nafion composite modified glassy carbon electrode as the voltammetric sensors for sensitive determination of 8-hydroxyquinoline in cosmetic”. Journal of Electroanalytical Chemistry, 655(1), 45-49, 2011.
  7. Xie X, Gan T, Sun D, Wu K. “Application of multi-walled carbon nanotubes/nafion composite film in electrochemical determination of Pb+2”. Fullerenes, Nanotubes and Carbon Nanostructures, 16(2), 103-113, 2008.
  8. Huang KJ, Liu X, Xie WZ, Yuan HX. “Electrochemical behavior and voltammetric determination of norfloxacin at glassy carbon electrode modified with multi walled carbon nanotubes/Nafion”. Colloids and Surfaces B: Biointerfaces. 64(2), 269-274, 2008.

Details

Primary Language

English

Subjects

Engineering

Journal Section

Research Article

Publication Date

December 28, 2018

Submission Date

December 29, 2016

Acceptance Date

-

Published in Issue

Year 2018 Volume: 24 Number: 7

APA
Çelik Kazıcı, H. (2018). Development of an ultra-sensitive method using nafion and multi-walled carbon nanotube coated glassy carbon electrode for atenolol determination. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi, 24(7), 1287-1292. https://izlik.org/JA88ED72LS
AMA
1.Çelik Kazıcı H. Development of an ultra-sensitive method using nafion and multi-walled carbon nanotube coated glassy carbon electrode for atenolol determination. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi. 2018;24(7):1287-1292. https://izlik.org/JA88ED72LS
Chicago
Çelik Kazıcı, Hilal. 2018. “Development of an Ultra-Sensitive Method Using Nafion and Multi-Walled Carbon Nanotube Coated Glassy Carbon Electrode for Atenolol Determination”. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi 24 (7): 1287-92. https://izlik.org/JA88ED72LS.
EndNote
Çelik Kazıcı H (December 1, 2018) Development of an ultra-sensitive method using nafion and multi-walled carbon nanotube coated glassy carbon electrode for atenolol determination. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi 24 7 1287–1292.
IEEE
[1]H. Çelik Kazıcı, “Development of an ultra-sensitive method using nafion and multi-walled carbon nanotube coated glassy carbon electrode for atenolol determination”, Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi, vol. 24, no. 7, pp. 1287–1292, Dec. 2018, [Online]. Available: https://izlik.org/JA88ED72LS
ISNAD
Çelik Kazıcı, Hilal. “Development of an Ultra-Sensitive Method Using Nafion and Multi-Walled Carbon Nanotube Coated Glassy Carbon Electrode for Atenolol Determination”. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi 24/7 (December 1, 2018): 1287-1292. https://izlik.org/JA88ED72LS.
JAMA
1.Çelik Kazıcı H. Development of an ultra-sensitive method using nafion and multi-walled carbon nanotube coated glassy carbon electrode for atenolol determination. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi. 2018;24:1287–1292.
MLA
Çelik Kazıcı, Hilal. “Development of an Ultra-Sensitive Method Using Nafion and Multi-Walled Carbon Nanotube Coated Glassy Carbon Electrode for Atenolol Determination”. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi, vol. 24, no. 7, Dec. 2018, pp. 1287-92, https://izlik.org/JA88ED72LS.
Vancouver
1.Hilal Çelik Kazıcı. Development of an ultra-sensitive method using nafion and multi-walled carbon nanotube coated glassy carbon electrode for atenolol determination. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi [Internet]. 2018 Dec. 1;24(7):1287-92. Available from: https://izlik.org/JA88ED72LS