Development of an ultra-sensitive method using nafion and multi-walled carbon nanotube coated glassy carbon electrode for atenolol determination
Abstract
Atenolol
(Scheme 1) is antihypertensive drug that form β-blocker group, which widely
used in the treatment of hypertension In this study, the redox properties of
the Tensinor drug used in blood pressure treatment were examined on modified
glassy carbon electrode and the electrodes prepared by coating carbon nanotubes
on this modified electrode. In order to investigate the effects of nafion
coated multi-walled glass nanotube (MWCNT / NGCE) electrode response and nafion
coated glassy carbon electrode (NGCE) and electrode responses of only glassy
carbon electrode (GCE) surfaces on the support electrolyte, pH and scan rate,
the cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods
were used. Atenolol (ATN) was observed in the Britton-Robinson (BR) buffer
solution (pH 7.0) thereabouts 1.11 V (vsAg / AgCl (3.0 mol L-1 KCl). Voltammetric
method reacted linear at a concentration range between 3x10-5 μM and 9x10-2 μM
under optimum analytical experimental conditions. The results of Tensinor's
limit of detection on the Britton-Robinson (BR) (pH=7) buffer were found to be
7.67 x 10-5 mM and 2.5 x 10-4 mM, respectively. Additionally, in the study,
interference effects experiments were performed with auxiliary substances used
in the preparation of medicines and no negative effect was observed.
Keywords
References
- Sudha T, Krishana KV, Nukala PCS, Saloman RT, Ganesan V. “Method development and validation”. Journal of Advanced Pharmacy Education & Research, 2(3), 146-176, 2012.
- Wang J. Analytical Electrochemistry, New Jersey, USA,Wiley-VCH Pub. 2006.
- Gupta, VK, Jain R, Radhapyari K, Jadon N, Agarwal S. “Voltammetric techniques for the assay of pharmaceuticals”. Analytical Biochemistry, 408(2), 179-196, 2011.
- Andrieux CP, Audebert P, Divisia-Blohorn B, Aldebert P, Michalak F. “Electrochemistry in Hydrophobic Nafion Gels”. Journal of Electroanalytical Chemistry, 296(1), 117-139, 1990.
- Svancara I, Vytras K, Kalcher K, Walcarius A, Wang J. “Carbon paste electrodes in facts, numbers, and notes: a review on the occasion of the 50-years jubilee of carbon paste in electrochemistry and electroanalysis”. Electroanalysis, 21(1), 7-28, 2009.
- Guo S, Wu X, Zhou J, Wang J, Yang B, Ye B. “MWNT/Nafion composite modified glassy carbon electrode as the voltammetric sensors for sensitive determination of 8-hydroxyquinoline in cosmetic”. Journal of Electroanalytical Chemistry, 655(1), 45-49, 2011.
- Xie X, Gan T, Sun D, Wu K. “Application of multi-walled carbon nanotubes/nafion composite film in electrochemical determination of Pb+2”. Fullerenes, Nanotubes and Carbon Nanostructures, 16(2), 103-113, 2008.
- Huang KJ, Liu X, Xie WZ, Yuan HX. “Electrochemical behavior and voltammetric determination of norfloxacin at glassy carbon electrode modified with multi walled carbon nanotubes/Nafion”. Colloids and Surfaces B: Biointerfaces. 64(2), 269-274, 2008.
Details