The motion mechanisms of manufacturing and robotic systems are developed in different structures, mainly in cartesian and delta structures having series or parallel movement abilities according to the capacity and construction structure of the system. Different systems are used according to the criteria such as bearing load capacity, sensitivity or cost of the system. In this study, the performances of machines installed in the delta and cartesian kinematic structures, which are mostly used in the kinematic systems of three - dimensional printers, were analyzed. In this context, in two different machines with these two construction structures, the same boundary conditions and 4 pieces of calibration parts especially in manufacturing features were printed. 23 different elements that constituted the calibration part were measured, tabulated, statistically analyzed, and the acceptable measuremental tolerance ranges of the elements were determined and the accuracy values of the machines were compared. As a result of this study, according to T test results, 15 of the 23 measurements on the Cartesian system based three-dimensional printers were obtained as acceptable in terms of tolerance range as well as 9 of the 23 different measurements were obtained as acceptable on Delta system. Consequently, operation accuracy of the Cartesian system based three-dimensional printers were higher than the Delta system under the same working conditions and manufacturing parameters.
Istanbul Gedik University
We would like to thank Istanbul Gedik University BAP Coordinator for supporting us in this study.
The motion mechanisms of manufacturing and robotic systems are developed in different structures, mainly in cartesian and delta structures having series or parallel movement abilities according to the capacity and construction structure of the system. Different systems are used according to the criteria such as bearing load capacity, sensitivity or cost of the system. In this study, the performances of machines installed in the delta and cartesian kinematic structures, which are mostly used in the kinematic systems of three - dimensional printers, were analyzed. In this context, in two different machines with these two construction structures, the same boundary conditions and 4 pieces of calibration parts especially in manufacturing features were printed. 23 different elements that constituted the calibration part were measured, tabulated, statistically analyzed, and the acceptable measuremental tolerance ranges of the elements were determined and the accuracy values of the machines were compared. As a result of this study, according to T test results, 15 of the 23 measurements on the Cartesian system based three-dimensional printers were obtained as acceptable in terms of tolerance range as well as 9 of the 23 different measurements were obtained as acceptable on Delta system. Consequently, operation accuracy of the Cartesian system based three-dimensional printers were higher than the Delta system under the same working conditions and manufacturing parameters.
Primary Language | English |
---|---|
Subjects | Engineering |
Journal Section | Research Article |
Authors | |
Publication Date | June 1, 2021 |
Submission Date | June 26, 2019 |
Published in Issue | Year 2021 |
Bu eser Creative Commons Atıf-AynıLisanslaPaylaş 4.0 Uluslararası ile lisanslanmıştır.