Percutaneous Crossing of a Complex Venous Stenosis That Occurred After Pacemaker Implantation: Rare Use of Seeker Crossing Support Catheter

Volume: 41 Number: 3 September 1, 2015
  • Ömer Fatih Nas
  • Emre Kaçar
  • Bekir Şanal
  • Kadir Hacıkurt
  • Saim Sağ
  • Cüneyt Erdoğan
EN TR

Percutaneous Crossing of a Complex Venous Stenosis That Occurred After Pacemaker Implantation: Rare Use of Seeker Crossing Support Catheter

Abstract

Venous thrombosis and stenosis are among the most common complications of pacemaker implantation. In recent years, percutaneous ap-proach has become an effective treatment option in central venous stenosis. Seeker crossing support catheter (SCSC) (Bard PV, Tempe) may be a good alternative with its superior tip entry to standard percutaneous techniques which do not help with complex stenoses. The purpose of this report was to present successful crossing of occlusion of the left subclavian and brachiocephalic veins that occurred after pacemaker implantation and recanalization of the central venous system with the SCSC following several unsuccessful percutaneous crossing attempts using standard techniques.

Keywords

Details

Primary Language

English

Subjects

-

Journal Section

-

Authors

Ömer Fatih Nas This is me

Emre Kaçar This is me

Bekir Şanal This is me

Kadir Hacıkurt This is me

Saim Sağ This is me

Cüneyt Erdoğan This is me

Publication Date

September 1, 2015

Submission Date

September 1, 2015

Acceptance Date

-

Published in Issue

Year 2015 Volume: 41 Number: 3

APA
Nas, Ö. F., Kaçar, E., Şanal, B., Hacıkurt, K., Sağ, S., & Erdoğan, C. (2015). Percutaneous Crossing of a Complex Venous Stenosis That Occurred After Pacemaker Implantation: Rare Use of Seeker Crossing Support Catheter. Journal of Uludağ University Medical Faculty, 41(3), 147-150. https://izlik.org/JA89DH79TX
AMA
1.Nas ÖF, Kaçar E, Şanal B, Hacıkurt K, Sağ S, Erdoğan C. Percutaneous Crossing of a Complex Venous Stenosis That Occurred After Pacemaker Implantation: Rare Use of Seeker Crossing Support Catheter. Journal of Uludağ University Medical Faculty. 2015;41(3):147-150. https://izlik.org/JA89DH79TX
Chicago
Nas, Ömer Fatih, Emre Kaçar, Bekir Şanal, Kadir Hacıkurt, Saim Sağ, and Cüneyt Erdoğan. 2015. “Percutaneous Crossing of a Complex Venous Stenosis That Occurred After Pacemaker Implantation: Rare Use of Seeker Crossing Support Catheter”. Journal of Uludağ University Medical Faculty 41 (3): 147-50. https://izlik.org/JA89DH79TX.
EndNote
Nas ÖF, Kaçar E, Şanal B, Hacıkurt K, Sağ S, Erdoğan C (September 1, 2015) Percutaneous Crossing of a Complex Venous Stenosis That Occurred After Pacemaker Implantation: Rare Use of Seeker Crossing Support Catheter. Journal of Uludağ University Medical Faculty 41 3 147–150.
IEEE
[1]Ö. F. Nas, E. Kaçar, B. Şanal, K. Hacıkurt, S. Sağ, and C. Erdoğan, “Percutaneous Crossing of a Complex Venous Stenosis That Occurred After Pacemaker Implantation: Rare Use of Seeker Crossing Support Catheter”, Journal of Uludağ University Medical Faculty, vol. 41, no. 3, pp. 147–150, Sept. 2015, [Online]. Available: https://izlik.org/JA89DH79TX
ISNAD
Nas, Ömer Fatih - Kaçar, Emre - Şanal, Bekir - Hacıkurt, Kadir - Sağ, Saim - Erdoğan, Cüneyt. “Percutaneous Crossing of a Complex Venous Stenosis That Occurred After Pacemaker Implantation: Rare Use of Seeker Crossing Support Catheter”. Journal of Uludağ University Medical Faculty 41/3 (September 1, 2015): 147-150. https://izlik.org/JA89DH79TX.
JAMA
1.Nas ÖF, Kaçar E, Şanal B, Hacıkurt K, Sağ S, Erdoğan C. Percutaneous Crossing of a Complex Venous Stenosis That Occurred After Pacemaker Implantation: Rare Use of Seeker Crossing Support Catheter. Journal of Uludağ University Medical Faculty. 2015;41:147–150.
MLA
Nas, Ömer Fatih, et al. “Percutaneous Crossing of a Complex Venous Stenosis That Occurred After Pacemaker Implantation: Rare Use of Seeker Crossing Support Catheter”. Journal of Uludağ University Medical Faculty, vol. 41, no. 3, Sept. 2015, pp. 147-50, https://izlik.org/JA89DH79TX.
Vancouver
1.Ömer Fatih Nas, Emre Kaçar, Bekir Şanal, Kadir Hacıkurt, Saim Sağ, Cüneyt Erdoğan. Percutaneous Crossing of a Complex Venous Stenosis That Occurred After Pacemaker Implantation: Rare Use of Seeker Crossing Support Catheter. Journal of Uludağ University Medical Faculty [Internet]. 2015 Sep. 1;41(3):147-50. Available from: https://izlik.org/JA89DH79TX

ISSN: 1300-414X, e-ISSN: 2645-9027

Creative Commons License
Journal of Uludag University Medical Faculty is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
2023