BibTex RIS Kaynak Göster

The Effect of the Evacuated Tube Collectors on Solar Pond Performance

Yıl 2014, Cilt: 4 Sayı: 1, 1 - 10, 27.11.2014

Öz

The present study deals with the effect of the evacuated tube solar collectors on the heat storage performance of a solar pond. For the experimental work, a solar pond system with a radius of 0.80 m and a depth of 1.60 m and four evacuated tube solar collectors was built in Cukurova University in Adana, Turkey. Heat energy collected by evacuated tube solar collectors was transferred to the solar pond storage zone by using a heat exchanger system. The temperature and density distribution of the system were measured by using thermocouples and hydrometers. Experimental studies were performed by using 1, 2, 3 and 4 evacuated tube solar collectors. As a result, the temperature increases in the solar pond were determined as 1.56, 2.37, 3.45 and 4.01 °C for 1, 2, 3 and 4 collectors, respectively. It is seen that the temperature of the solar pond has increased from 15 °C to 25 °C within four days.

Kaynakça

  • N. Kılıç, Yenilenebilir Enerji Kaynakları, Ar-Ge Bülten Mart-Sektörel, İzmir Ticaret Odası, 2008.
  • M.A. Ersöz, A. Yıldız, Tesisat Mühendisliği, 2013, 133, 5.
  • M. Karakilcik, I. Dincer, I. Bozkurt, A. Atiz, Energy Convers Manage, 2013, 65, 98. M. Karakilcik, I. Dincer, M.A. Rosen, Appl Thermal Eng, 2006, 26, 727.
  • M. Karakilcik, K. Kıymac, I. Dincer, Int J Heat Mass Transfer, 2006, 49, 825.
  • M. Karakilcik, I. Dincer, Int J Thermal Sciences, 2008, 47, 93.
  • N. Sharma, G. Diaz, Solar Energy, 2011, 85, 881.
  • I. Bozkurt, M. Karakilcik, Solar Energy, 2012, 86, 1611.
  • M. Karakilcik, I. Bozkurt, I. Dincer, Int J Exergy, 2013, 12, 70.
  • I. Bozkurt, A. Atiz, M. Karakilcik, I. Dincer, Int J Green Energy, 2014, 11, 404.

Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi

Yıl 2014, Cilt: 4 Sayı: 1, 1 - 10, 27.11.2014

Öz

Bu çalışma vakum tüplü güneş kollektörlerinin güneş havuzunun ısı depolama performansı üzerine etkisi ile ilgilidir. Deneysel çalışma için, 0.80 m yarıçaplı, 1.60 m derinlikli ve dört vakum tüplü güneş kollektörlü bir güneş havuzu sistemi Çukurova Üniversitesi, Adana, Türkiye’de kurulmuştur. Vakum tüplü güneş kollektörleri tarafından toplanan ısı enerjisi bir ısı değiştirici sistem kullanılarak güneş havuzunun depolama bölgesine transfer edilmiştir. Sistemin sıcaklık ve yoğunluk dağılımları ısıl çiftler ve hidrometreler kullanılarak ölçülmüştür. Deneysel çalışmalar 1, 2, 3 ve 4 vakum tüplü güneş kollektörü kullanılarak gerçekleştirilmiştir. Sonuç olarak, güneş havuzundaki sıcaklık artışları 1, 2, 3 ve 4 kollektör için sırasıyla 1.56, 2.37, 3.45 ve 4.01 °C olarak belirlenmiştir. Güneş havuzunun sıcaklığının dört gün içerisinde 15 °C’den 25 °C’ye kadar arttığı görülmüştür.

Kaynakça

  • N. Kılıç, Yenilenebilir Enerji Kaynakları, Ar-Ge Bülten Mart-Sektörel, İzmir Ticaret Odası, 2008.
  • M.A. Ersöz, A. Yıldız, Tesisat Mühendisliği, 2013, 133, 5.
  • M. Karakilcik, I. Dincer, I. Bozkurt, A. Atiz, Energy Convers Manage, 2013, 65, 98. M. Karakilcik, I. Dincer, M.A. Rosen, Appl Thermal Eng, 2006, 26, 727.
  • M. Karakilcik, K. Kıymac, I. Dincer, Int J Heat Mass Transfer, 2006, 49, 825.
  • M. Karakilcik, I. Dincer, Int J Thermal Sciences, 2008, 47, 93.
  • N. Sharma, G. Diaz, Solar Energy, 2011, 85, 881.
  • I. Bozkurt, M. Karakilcik, Solar Energy, 2012, 86, 1611.
  • M. Karakilcik, I. Bozkurt, I. Dincer, Int J Exergy, 2013, 12, 70.
  • I. Bozkurt, A. Atiz, M. Karakilcik, I. Dincer, Int J Green Energy, 2014, 11, 404.
Toplam 9 adet kaynakça vardır.

Ayrıntılar

Birincil Dil Türkçe
Bölüm Araştırma Makaleleri
Yazarlar

İsmail Bozkurt Bu kişi benim

Ayhan Atız Bu kişi benim

İsmail Bozkurt Bu kişi benim

Mehmet Karakılçık Bu kişi benim

Mehmet Karakılçık Bu kişi benim

Yayımlanma Tarihi 27 Kasım 2014
Yayımlandığı Sayı Yıl 2014 Cilt: 4 Sayı: 1

Kaynak Göster

APA Bozkurt, İ., Atız, A., Bozkurt, İ., Karakılçık, M., vd. (2014). Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi. Adıyaman University Journal of Educational Sciences, 4(1), 1-10.
AMA Bozkurt İ, Atız A, Bozkurt İ, Karakılçık M, Karakılçık M. Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi. ADYUEBD. Haziran 2014;4(1):1-10.
Chicago Bozkurt, İsmail, Ayhan Atız, İsmail Bozkurt, Mehmet Karakılçık, ve Mehmet Karakılçık. “Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi”. Adıyaman University Journal of Educational Sciences 4, sy. 1 (Haziran 2014): 1-10.
EndNote Bozkurt İ, Atız A, Bozkurt İ, Karakılçık M, Karakılçık M (01 Haziran 2014) Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi. Adıyaman University Journal of Educational Sciences 4 1 1–10.
IEEE İ. Bozkurt, A. Atız, İ. Bozkurt, M. Karakılçık, ve M. Karakılçık, “Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi”, ADYUEBD, c. 4, sy. 1, ss. 1–10, 2014.
ISNAD Bozkurt, İsmail vd. “Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi”. Adıyaman University Journal of Educational Sciences 4/1 (Haziran 2014), 1-10.
JAMA Bozkurt İ, Atız A, Bozkurt İ, Karakılçık M, Karakılçık M. Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi. ADYUEBD. 2014;4:1–10.
MLA Bozkurt, İsmail vd. “Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi”. Adıyaman University Journal of Educational Sciences, c. 4, sy. 1, 2014, ss. 1-10.
Vancouver Bozkurt İ, Atız A, Bozkurt İ, Karakılçık M, Karakılçık M. Vakum Tüplü Kollektörlerin Güneş Havuzu Performansı Üzerine Etkisi. ADYUEBD. 2014;4(1):1-10.

29929 Bu eser Creative Commons Atıf-GayriTicari Lisansı ile lisanslanmıştır.