Araştırma Makalesi

Hydro-atmospheric conditions during the 2007 Attica wildfire period: A multi-sensor assessment

Sayı: 13 13 Kasım 2026
PDF İndir
EN TR

Hydro-atmospheric conditions during the 2007 Attica wildfire period: A multi-sensor assessment

Öz

Background and Aims This study examined hydro-atmospheric conditions during the 2007 Attica wildfire period using complementary observations at different time scales. Methods GRACE total water storage anomalies (TWSA), GLDAS-Noah soil moisture storage anomalies (SMSA), daily GNSS-derived precipitable water vapor (PWV) from ten stations, and MODIS FIRMS active-fire data were analyzed. Results MODIS FIRMS identified prominent fire clusters on 16 and 25 August 2007. Deseasonalized GRACE-TWSA and GLDAS-SMSA were moderately correlated (r = 0.467; adjusted p < 0.001). The May-August GRACE-TWSA mean was low (z = -2.61), while GLDAS was also negative (z = -1.02). GNSS-PWV was coherent across the network (median Spearman rho = 0.840; p = 0.0002). Mean PWV departures were -0.29 mm on 16 August and -7.08 mm on 25 August; all stations were negative on 25 August. Conclusion The results indicate regional hydrological depletion together with short-term atmospheric moisture variability. This case study provides environmental context and does not establish causality or a PWV warning threshold.

Anahtar Kelimeler

Destekleyen Kurum

No external funding.

Etik Beyan

This study did not involve human participants, animals, personal data, or sensitive information and therefore did not require ethics committee approval. The research was conducted using publicly available environmental and geodetic data products. No additional ethical approval or specific legal authorization was required.

Teşekkür

We sincerely thank the Jet Propulsion Laboratory (JPL) for providing the GRACE RL06.1 Mascon products, the NASA Global Land Data Assimilation System (GLDAS-Noah Version 2.1) team for the land-surface model outputs, the Nevada Geodetic Laboratory (NGL), University of Nevada Reno, for the GNSS tropospheric products, and NASA FIRMS/MODIS for the active-fire and MCD64A1 burned-area observations used in this study. The author also thanks Erdem Kazancı for preparing and providing the pre-processed GRACE and GLDAS time series used as input to the hydrological analysis.

Kaynakça

  1. Agutu, N. O., Ndehedehe, C. E., Awange, J. L., Kirimi, F., Mwaniki, M., 2021. Understanding uncertainty of model-reanalysis soil moisture within Greater Horn of Africa (1982–2014). Journal of Hydrology, 603, 127169. https://doi.org/10.1016/j.jhydrol.2021.127169.
  2. Arianoutsou, M., Athanasakis, G., Kazanis, D., Christopoulou, A., 2024. Attica: a hot spot for forest fires in Greece. Fire, 7(12), 467. https://doi.org/10.3390/fire7120467.
  3. Blank, D., Eicker, A., Jensen, L., Güntner, A., 2023. A global analysis of water storage variations from remotely sensed soil moisture and daily satellite gravimetry. Hydrology and Earth System Sciences, 27, 2413–2435. https://doi.org/10.5194/hess-27-2413-2023.
  4. Blank, D., Eicker, A., Reager, J. T., Güntner, A., 2025. Revisiting sub-surface drought cascades with daily satellite observations of soil moisture and terrestrial water storage. Water Resources Research, 61(8), e2024WR039321. https://doi.org/10.1029/2024WR039321.
  5. Chen, Y., Velicogna, I., Famiglietti, J. S., Randerson, J. T., 2013. Satellite observations of terrestrial water storage provide early warning information about drought and fire season severity in the Amazon. Journal of Geophysical Research: Biogeosciences, 118(2), 495–504. https://doi.org/10.1002/jgrg.20046.
  6. Copernicus Climate Change Service, 2020. Fire danger indicators for Europe from 1970 to 2098 derived from climate projections [Data set]. Climate Data Store. https://doi.org/10.24381/cds.ca755de7.
  7. Dimitrakopoulos, A. P., Vlahou, M., Anagnostopoulou, Ch. G., Mitsopoulos, I. D., 2011. Impact of drought on wildland fires in Greece: Implications of climatic change? Climatic Change, 109, 331–347. https://doi.org/10.1007/s10584-011-0026-8.
  8. Fang, H., Beaudoing, H.K., Rodell, M., Teng, W.L., Vollmer, B.E., 2009. Global Land Data Assimilation System (GLDAS) products, services and application from NASA Hydrology Data and Information Services Center (HDISC). ASPRS 2009 Annual Conference, Baltimore, Maryland, USA, 8–13 March 2009, 9 pp.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Orman Yangın Yönetimi, Ormancılıkta Havza Yönetimi

Bölüm

Araştırma Makalesi

Yazarlar

Selma Zengin Kazancı *
Osmaniye Korkut Ata University, Faculty of Engineering and Natural Sciences, Department of Geomatics Engineering,80000
0000-0003-1795-5367
Türkiye

Yayımlanma Tarihi

13 Kasım 2026

Gönderilme Tarihi

25 Eylül 2026

Kabul Tarihi

20 Ekim 2026

Yayımlandığı Sayı

Yıl 2026 Sayı: 13

Kaynak Göster

APA
Zengin Kazancı, S. (2026). Hydro-atmospheric conditions during the 2007 Attica wildfire period: A multi-sensor assessment. Anadolu Orman Araştırmaları Dergisi, 13, 2047927. https://doi.org/10.53516/ajfr.2047927
AMA
1.Zengin Kazancı S. Hydro-atmospheric conditions during the 2007 Attica wildfire period: A multi-sensor assessment. AOAD. 2026;(13):2047927. doi:10.53516/ajfr.2047927
Chicago
Zengin Kazancı, Selma. 2026. “Hydro-atmospheric conditions during the 2007 Attica wildfire period: A multi-sensor assessment”. Anadolu Orman Araştırmaları Dergisi, sy 13: 2047927. https://doi.org/10.53516/ajfr.2047927.
EndNote
Zengin Kazancı S (13 Kasım 2026) Hydro-atmospheric conditions during the 2007 Attica wildfire period: A multi-sensor assessment. Anadolu Orman Araştırmaları Dergisi 13 2047927.
IEEE
[1]S. Zengin Kazancı, “Hydro-atmospheric conditions during the 2007 Attica wildfire period: A multi-sensor assessment”, AOAD, sy 13, s. 2047927, Kas. 2026, doi: 10.53516/ajfr.2047927.
ISNAD
Zengin Kazancı, Selma. “Hydro-atmospheric conditions during the 2007 Attica wildfire period: A multi-sensor assessment”. Anadolu Orman Araştırmaları Dergisi. 13 (13 Kasım 2026): 2047927. https://doi.org/10.53516/ajfr.2047927.
JAMA
1.Zengin Kazancı S. Hydro-atmospheric conditions during the 2007 Attica wildfire period: A multi-sensor assessment. AOAD. 2026;:2047927.
MLA
Zengin Kazancı, Selma. “Hydro-atmospheric conditions during the 2007 Attica wildfire period: A multi-sensor assessment”. Anadolu Orman Araştırmaları Dergisi, sy 13, Kasım 2026, s. 2047927, doi:10.53516/ajfr.2047927.
Vancouver
1.Selma Zengin Kazancı. Hydro-atmospheric conditions during the 2007 Attica wildfire period: A multi-sensor assessment. AOAD. 13 Kasım 2026;(13):2047927. doi:10.53516/ajfr.2047927