Araştırma Makalesi

Stopping Power and Range Calculations of Electrons For Some Human Body Tissues

28 Mart 2019
PDF İndir
EN

Stopping Power and Range Calculations of Electrons For Some Human Body Tissues

Öz

This study presents calculation results of the stopping power and range of electrons of kinetic energy from 20 eV to 10 MeV for some human body tissues. The method is based on utilization of the modified Bethe-Bloch stopping power expression and analytical expression for effective atomic electron number and effective mean excitation energies of target atoms, and for effective charge of incoming electrons. For this aim, Sugiyama’s semi-empirical formula from Petersen and Green is embedded in the formula. An analytical expression for the practical stopping power calculations using Bethe approximation and Thomas-Fermi Model of atom is taken from the previous study.


The calculated results of the stopping power and range for electrons in some materials, such as adipose tissue, bone and water are compared with a number of other calculation such as the Penelope 14 code and ESTAR results. The present electron stopping power and range calculation method should be useful in nuclear medicine, radiation treatment, and biomedical dosimetry.


 


Anahtar Kelimeler

Kaynakça

  1. [1] M. J. Berger, S. M. Seltzer, NAS-NRC Publ. No. 1133, Natl. Acad. Sci. Natl. Res. Council, Washington (1964) pp. 205–268.
  2. [2] L. Pages, E. Bertel, H. Joffre, L. Sklavenitis, Atomic Data 4, 1 (1972).
  3. [3] ICRU, Report No. 37, Stopping powers for electrons and positrons. International Commission on Radiation Units and Measurements, Bethesda, MD. (1984).
  4. [4] L. R. Peterson, A.E.S. Green, J. Phys. B 1, 1131 (1968).
  5. [5] H. Sugiyama, Radiat. Eff. 56, 205 (1981).
  6. [6] H. Sugiyama, Phys. Med. Biol. 30, 4, 331 (1985).
  7. [7] W. Lenz, Zeitung F. Physik, 77, 722 (1932).
  8. [8] H. Jensen, Zeitung F. Physik, 77, 713 (1932).

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

Araştırma Makalesi

Yazarlar

Yayımlanma Tarihi

28 Mart 2019

Gönderilme Tarihi

29 Kasım 2018

Kabul Tarihi

25 Aralık 2018

Yayımlandığı Sayı

Yıl 2019

Kaynak Göster

APA
Gümüş, H. (2019). Stopping Power and Range Calculations of Electrons For Some Human Body Tissues. ALKÜ Fen Bilimleri Dergisi, 93-100. https://izlik.org/JA44RA43HN
AMA
1.Gümüş H. Stopping Power and Range Calculations of Electrons For Some Human Body Tissues. ALKÜ Fen Bilimleri Dergisi. Published online 01 Mart 2019:93-100. https://izlik.org/JA44RA43HN
Chicago
Gümüş, Hasan. 2019. “Stopping Power and Range Calculations of Electrons For Some Human Body Tissues”. ALKÜ Fen Bilimleri Dergisi, Mart 1, 93-100. https://izlik.org/JA44RA43HN.
EndNote
Gümüş H (01 Mart 2019) Stopping Power and Range Calculations of Electrons For Some Human Body Tissues. ALKÜ Fen Bilimleri Dergisi 93–100.
IEEE
[1]H. Gümüş, “Stopping Power and Range Calculations of Electrons For Some Human Body Tissues”, ALKÜ Fen Bilimleri Dergisi, ss. 93–100, Mar. 2019, [çevrimiçi]. Erişim adresi: https://izlik.org/JA44RA43HN
ISNAD
Gümüş, Hasan. “Stopping Power and Range Calculations of Electrons For Some Human Body Tissues”. ALKÜ Fen Bilimleri Dergisi. 01 Mart 2019. 93-100. https://izlik.org/JA44RA43HN.
JAMA
1.Gümüş H. Stopping Power and Range Calculations of Electrons For Some Human Body Tissues. ALKÜ Fen Bilimleri Dergisi. 2019;:93–100.
MLA
Gümüş, Hasan. “Stopping Power and Range Calculations of Electrons For Some Human Body Tissues”. ALKÜ Fen Bilimleri Dergisi, Mart 2019, ss. 93-100, https://izlik.org/JA44RA43HN.
Vancouver
1.Hasan Gümüş. Stopping Power and Range Calculations of Electrons For Some Human Body Tissues. ALKÜ Fen Bilimleri Dergisi [Internet]. 01 Mart 2019;93-100. Erişim adresi: https://izlik.org/JA44RA43HN