EN
TR
Treatment of unstable fractures of the spine with the Cotrel-Dubousset instrumentation
Öz
This study reviews 13 unstable spinal fractures, which were stabilized with the Cotrel-Oubousset instrumentation, at the Ankara University Ibn-i Sina Hospital between Nowember 1989 and July 1991. AII fractures were considered ''unstable'' according to Denis “three column spine concept” and 10 of them involved middle and posterior columns, 3 of them anterior, middle and posterior columns. The age at operation ranged from 19 to 64 years with an average of 38.6 years. The average follow-up period was 7.1 months (2-18- months). All patients were evaluated both radiographically and clinically. The average local kyphosis angle was 30.7° preoperatively, and 20.7° postoperatively (32% improvement). The average correction Ioss was 2.5°. The average anterior vertebral body height improved from 49 % to 58 % and the average posterior vertebral height from 79% to 86%. A postoperative improvement of one step in the "Frankel classification" occured in 2 patients. Complications included 1 exitus, due to ARDS and 1 deep infection, treated with surgical drainage and appropriate antibiotic therapy. As Cotrel-Oubousset instrumentation achieves stable osteosynthesis in unstable fractures of the spine, and shortens the time of ambulation and hospitalization, it is an important alternative in this section
Anahtar Kelimeler
Ayrıntılar
Birincil Dil
İngilizce
Konular
-
Bölüm
-
Yayımlanma Tarihi
11 Eylül 2006
Gönderilme Tarihi
6 Mart 2014
Kabul Tarihi
-
Yayımlandığı Sayı
Yıl 1992 Cilt: 26 Sayı: 2
APA
Dincer, M., Omeroglu, H., & Cetin, İ. (2006). Treatment of unstable fractures of the spine with the Cotrel-Dubousset instrumentation. Acta Orthopaedica et Traumatologica Turcica, 26(2), 85-88. https://doi.org/10.3944/aott.v26i2.1299
AMA
1.Dincer M, Omeroglu H, Cetin İ. Treatment of unstable fractures of the spine with the Cotrel-Dubousset instrumentation. Acta Orthopaedica et Traumatologica Turcica. 2006;26(2):85-88. doi:10.3944/aott.v26i2.1299
Chicago
Dincer, M., Hakan Omeroglu, ve İlker Cetin. 2006. “Treatment of unstable fractures of the spine with the Cotrel-Dubousset instrumentation”. Acta Orthopaedica et Traumatologica Turcica 26 (2): 85-88. https://doi.org/10.3944/aott.v26i2.1299.
EndNote
Dincer M, Omeroglu H, Cetin İ (01 Eylül 2006) Treatment of unstable fractures of the spine with the Cotrel-Dubousset instrumentation. Acta Orthopaedica et Traumatologica Turcica 26 2 85–88.
IEEE
[1]M. Dincer, H. Omeroglu, ve İ. Cetin, “Treatment of unstable fractures of the spine with the Cotrel-Dubousset instrumentation”, Acta Orthopaedica et Traumatologica Turcica, c. 26, sy 2, ss. 85–88, Eyl. 2006, doi: 10.3944/aott.v26i2.1299.
ISNAD
Dincer, M. - Omeroglu, Hakan - Cetin, İlker. “Treatment of unstable fractures of the spine with the Cotrel-Dubousset instrumentation”. Acta Orthopaedica et Traumatologica Turcica 26/2 (01 Eylül 2006): 85-88. https://doi.org/10.3944/aott.v26i2.1299.
JAMA
1.Dincer M, Omeroglu H, Cetin İ. Treatment of unstable fractures of the spine with the Cotrel-Dubousset instrumentation. Acta Orthopaedica et Traumatologica Turcica. 2006;26:85–88.
MLA
Dincer, M., vd. “Treatment of unstable fractures of the spine with the Cotrel-Dubousset instrumentation”. Acta Orthopaedica et Traumatologica Turcica, c. 26, sy 2, Eylül 2006, ss. 85-88, doi:10.3944/aott.v26i2.1299.
Vancouver
1.M. Dincer, Hakan Omeroglu, İlker Cetin. Treatment of unstable fractures of the spine with the Cotrel-Dubousset instrumentation. Acta Orthopaedica et Traumatologica Turcica. 01 Eylül 2006;26(2):85-8. doi:10.3944/aott.v26i2.1299