Treatment of intertrochanteric femur fractures with 130 degree AO plate

Cilt: 32 Sayı: 1 11 Eylül 2006
  • Bulent Aksoy
  • Ridvan Yesiltepe
  • C. Esenyel
  • Ercan Olcay
  • A. Kara
PDF İndir
EN TR

Treatment of intertrochanteric femur fractures with 130 degree AO plate

Öz

In this, study, we rewiewed the results of 42 patients treated for intertrochanteric fractures using 130 degree AO plate in our hospital between June 1992 and April 1995 with an average follow-up of 30 months. We obtained a union rate of 100% and the average Merle d' Aubigne hip rating score was found to be 15,4 (good). We determined excellent and good results at 76% (32 patients) of them. As a result of this study, we concluded using of 130 degree AO plate, in intertrochanteric fractures of femur is a reliable surgical treatment method.

Anahtar Kelimeler

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

-

Yazarlar

Bulent Aksoy Bu kişi benim

Ridvan Yesiltepe Bu kişi benim

C. Esenyel Bu kişi benim

Ercan Olcay Bu kişi benim

Yayımlanma Tarihi

11 Eylül 2006

Gönderilme Tarihi

6 Mart 2014

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 1998 Cilt: 32 Sayı: 1

Kaynak Göster

APA
Aksoy, B., Yesiltepe, R., Esenyel, C., Olcay, E., & Kara, A. (2006). Treatment of intertrochanteric femur fractures with 130 degree AO plate. Acta Orthopaedica et Traumatologica Turcica, 32(1), 44-47. https://doi.org/10.3944/aott.v32i1.2226
AMA
1.Aksoy B, Yesiltepe R, Esenyel C, Olcay E, Kara A. Treatment of intertrochanteric femur fractures with 130 degree AO plate. Acta Orthopaedica et Traumatologica Turcica. 2006;32(1):44-47. doi:10.3944/aott.v32i1.2226
Chicago
Aksoy, Bulent, Ridvan Yesiltepe, C. Esenyel, Ercan Olcay, ve A. Kara. 2006. “Treatment of intertrochanteric femur fractures with 130 degree AO plate”. Acta Orthopaedica et Traumatologica Turcica 32 (1): 44-47. https://doi.org/10.3944/aott.v32i1.2226.
EndNote
Aksoy B, Yesiltepe R, Esenyel C, Olcay E, Kara A (01 Eylül 2006) Treatment of intertrochanteric femur fractures with 130 degree AO plate. Acta Orthopaedica et Traumatologica Turcica 32 1 44–47.
IEEE
[1]B. Aksoy, R. Yesiltepe, C. Esenyel, E. Olcay, ve A. Kara, “Treatment of intertrochanteric femur fractures with 130 degree AO plate”, Acta Orthopaedica et Traumatologica Turcica, c. 32, sy 1, ss. 44–47, Eyl. 2006, doi: 10.3944/aott.v32i1.2226.
ISNAD
Aksoy, Bulent - Yesiltepe, Ridvan - Esenyel, C. - Olcay, Ercan - Kara, A. “Treatment of intertrochanteric femur fractures with 130 degree AO plate”. Acta Orthopaedica et Traumatologica Turcica 32/1 (01 Eylül 2006): 44-47. https://doi.org/10.3944/aott.v32i1.2226.
JAMA
1.Aksoy B, Yesiltepe R, Esenyel C, Olcay E, Kara A. Treatment of intertrochanteric femur fractures with 130 degree AO plate. Acta Orthopaedica et Traumatologica Turcica. 2006;32:44–47.
MLA
Aksoy, Bulent, vd. “Treatment of intertrochanteric femur fractures with 130 degree AO plate”. Acta Orthopaedica et Traumatologica Turcica, c. 32, sy 1, Eylül 2006, ss. 44-47, doi:10.3944/aott.v32i1.2226.
Vancouver
1.Bulent Aksoy, Ridvan Yesiltepe, C. Esenyel, Ercan Olcay, A. Kara. Treatment of intertrochanteric femur fractures with 130 degree AO plate. Acta Orthopaedica et Traumatologica Turcica. 01 Eylül 2006;32(1):44-7. doi:10.3944/aott.v32i1.2226