Comparison of temperature increments in bone cavities induced by methylmethacrylate and heated saline solution

Öz

Objectives: We administered saline solution at 70 °C and methylmethacrylate to varying volumes of bone cavities and compared temperature changes produced in bone regions at varying distances to the cavity wall. Methods: We created varying sizes of cavities in the femoral heads of 20 human cadavers (6, 10, 12, and 20 cm3) and in the knee region of a human cadaver (6, 10, 12, 20, 30, and 40 cm3). Initially, saline solution at 70 °C was administered to all the cavities for 15 minutes by a pulse-irrigation method, during which temperature changes induced within the bone cavity and at specific distances (1 mm, 2 mm, 3 mm, and 10 mm) to the cavity wall were recorded. The bone temperatures were allowed to return to initial values; thereafter, cement was applied and temperature changes at the same distances to the cavity wall, in the cement center, and on the cement surface were recorded. Results: Cement volumes up to 40 cm3 applied to the bone cavities did not produce temperature increments that are reported to be adequate to induce necrosis in the cavity wall. It was thought that cement-induced necrosis in the bone-cement interface was not related to heat, but to other effects exerted by cement application. Compared to cement-induced temperature changes, saline solution at 70 °C was always associated with higher temperature increments in the cavity wall. Conclusion: Due to its simple applicability at desired temperatures and for any lengths of time, heated saline solution seems to have credentials to be incorporated into local adjuvants that are utilized to eliminate tumoral contamination in the cavity wall following curettage for local aggressive tumors.

Anahtar Kelimeler

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

-

Yazarlar

Neslihan Aksu Bu kişi benim

M. Bilgili Bu kişi benim

Taner Aksu Bu kişi benim

Oktay Duzgun Bu kişi benim

Yayımlanma Tarihi

11 Eylül 2006

Gönderilme Tarihi

6 Mart 2014

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2003 Cilt: 37 Sayı: 5

Kaynak Göster

APA
Aksu, N., Hiz, V., Bilgili, M., Aksu, T., & Duzgun, O. (2006). Comparison of temperature increments in bone cavities induced by methylmethacrylate and heated saline solution. Acta Orthopaedica et Traumatologica Turcica, 37(5), 386-394. https://doi.org/10.3944/aott.v37i5.804
AMA
1.Aksu N, Hiz V, Bilgili M, Aksu T, Duzgun O. Comparison of temperature increments in bone cavities induced by methylmethacrylate and heated saline solution. Acta Orthopaedica et Traumatologica Turcica. 2006;37(5):386-394. doi:10.3944/aott.v37i5.804
Chicago
Aksu, Neslihan, VM Hiz, M. Bilgili, Taner Aksu, ve Oktay Duzgun. 2006. “Comparison of temperature increments in bone cavities induced by methylmethacrylate and heated saline solution”. Acta Orthopaedica et Traumatologica Turcica 37 (5): 386-94. https://doi.org/10.3944/aott.v37i5.804.
EndNote
Aksu N, Hiz V, Bilgili M, Aksu T, Duzgun O (01 Eylül 2006) Comparison of temperature increments in bone cavities induced by methylmethacrylate and heated saline solution. Acta Orthopaedica et Traumatologica Turcica 37 5 386–394.
IEEE
[1]N. Aksu, V. Hiz, M. Bilgili, T. Aksu, ve O. Duzgun, “Comparison of temperature increments in bone cavities induced by methylmethacrylate and heated saline solution”, Acta Orthopaedica et Traumatologica Turcica, c. 37, sy 5, ss. 386–394, Eyl. 2006, doi: 10.3944/aott.v37i5.804.
ISNAD
Aksu, Neslihan - Hiz, VM - Bilgili, M. - Aksu, Taner - Duzgun, Oktay. “Comparison of temperature increments in bone cavities induced by methylmethacrylate and heated saline solution”. Acta Orthopaedica et Traumatologica Turcica 37/5 (01 Eylül 2006): 386-394. https://doi.org/10.3944/aott.v37i5.804.
JAMA
1.Aksu N, Hiz V, Bilgili M, Aksu T, Duzgun O. Comparison of temperature increments in bone cavities induced by methylmethacrylate and heated saline solution. Acta Orthopaedica et Traumatologica Turcica. 2006;37:386–394.
MLA
Aksu, Neslihan, vd. “Comparison of temperature increments in bone cavities induced by methylmethacrylate and heated saline solution”. Acta Orthopaedica et Traumatologica Turcica, c. 37, sy 5, Eylül 2006, ss. 386-94, doi:10.3944/aott.v37i5.804.
Vancouver
1.Neslihan Aksu, VM Hiz, M. Bilgili, Taner Aksu, Oktay Duzgun. Comparison of temperature increments in bone cavities induced by methylmethacrylate and heated saline solution. Acta Orthopaedica et Traumatologica Turcica. 01 Eylül 2006;37(5):386-94. doi:10.3944/aott.v37i5.804