Biomechonical problems encountered in the hip joint following the applicational total endoprosthesis (Significance of the femoral varus deformity in respect of proshetic bosening)

Öz

In this study, attempts have been made to relate the altered biomechanic following total endoprosthetic application in the hip joint. Both the surgical procedure and the choice of material considerabiy affect the life and durability of the prosthesis in the application of total endoprosthesis. For instance, it is imperative that the length of the neck of the prosthesis should not exceed 35 mm and the CCD angle of the prosthesis should not be less than 140. Furthermore. The femoral varus deformity has been described to be the latent factor in increasing the bending moment and predisposing the loosening.

Anahtar Kelimeler

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

-

Yazarlar

Yayımlanma Tarihi

20 Kasım 1981

Gönderilme Tarihi

7 Mart 2014

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 1981 Cilt: 15 Sayı: 4

Kaynak Göster

APA
Yucel, M. (1981). Biomechonical problems encountered in the hip joint following the applicational total endoprosthesis (Significance of the femoral varus deformity in respect of proshetic bosening). Acta Orthopaedica et Traumatologica Turcica, 15(4), 211-237. https://doi.org/10.3944/aott.v15i4.3200
AMA
1.Yucel M. Biomechonical problems encountered in the hip joint following the applicational total endoprosthesis (Significance of the femoral varus deformity in respect of proshetic bosening). Acta Orthopaedica et Traumatologica Turcica. 1981;15(4):211-237. doi:10.3944/aott.v15i4.3200
Chicago
Yucel, M. 1981. “Biomechonical problems encountered in the hip joint following the applicational total endoprosthesis (Significance of the femoral varus deformity in respect of proshetic bosening)”. Acta Orthopaedica et Traumatologica Turcica 15 (4): 211-37. https://doi.org/10.3944/aott.v15i4.3200.
EndNote
Yucel M (01 Kasım 1981) Biomechonical problems encountered in the hip joint following the applicational total endoprosthesis (Significance of the femoral varus deformity in respect of proshetic bosening). Acta Orthopaedica et Traumatologica Turcica 15 4 211–237.
IEEE
[1]M. Yucel, “Biomechonical problems encountered in the hip joint following the applicational total endoprosthesis (Significance of the femoral varus deformity in respect of proshetic bosening)”, Acta Orthopaedica et Traumatologica Turcica, c. 15, sy 4, ss. 211–237, Kas. 1981, doi: 10.3944/aott.v15i4.3200.
ISNAD
Yucel, M. “Biomechonical problems encountered in the hip joint following the applicational total endoprosthesis (Significance of the femoral varus deformity in respect of proshetic bosening)”. Acta Orthopaedica et Traumatologica Turcica 15/4 (01 Kasım 1981): 211-237. https://doi.org/10.3944/aott.v15i4.3200.
JAMA
1.Yucel M. Biomechonical problems encountered in the hip joint following the applicational total endoprosthesis (Significance of the femoral varus deformity in respect of proshetic bosening). Acta Orthopaedica et Traumatologica Turcica. 1981;15:211–237.
MLA
Yucel, M. “Biomechonical problems encountered in the hip joint following the applicational total endoprosthesis (Significance of the femoral varus deformity in respect of proshetic bosening)”. Acta Orthopaedica et Traumatologica Turcica, c. 15, sy 4, Kasım 1981, ss. 211-37, doi:10.3944/aott.v15i4.3200.
Vancouver
1.M. Yucel. Biomechonical problems encountered in the hip joint following the applicational total endoprosthesis (Significance of the femoral varus deformity in respect of proshetic bosening). Acta Orthopaedica et Traumatologica Turcica. 01 Kasım 1981;15(4):211-37. doi:10.3944/aott.v15i4.3200