Thrust plate prosthesis for proximal femoral deformity: a series of 15 patients
Abstract
Methods: Fifteen patients (7 females, 8 males) with a mean age of 56.4 years (range 19-75 years) at the time of the surgery were included in the study. The etiology was traumatic coxarthrosis in 12, and nonunion of a femoral neck fracture with osteonecrosis of the femoral head in the remaining three. While the femoral component was a third-generation TPP in all patients, the acetabular component was a Protek expansion cup in 12, and a cementless standard cup in three patients. All operations were performed through a Hardinge approach. Patients were followed up for at least 3 years (range 36-116 months) and evaluated clinically with the Harris Hip Score.
Results: The mean preoperative Harris Hip Score increased from 51.2 (range 15-79) to 92.7 (range 60-100) at the latest assessment. In two cases, loosening of the femoral component was observed in zone 3, both 12 months postoperatively. One was replaced by an intramedullary prosthesis, and the other was asymptomatic.
Conclusion: TPP is a good alternative for patients with deformations of the proximal femur. The use of TPP avoids technical difficulties and a custom-made prosthesis.
Keywords
Ayrıntılar
Birincil Dil
İngilizce
Konular
Sağlık Kurumları Yönetimi
Bölüm
Araştırma Makalesi
Yazarlar
Vasfi Karatosun
Bu kişi benim
Bayram Ünver
Bu kişi benim
Alper Gultekin
Bu kişi benim
Izge Gunal
Bu kişi benim
Yayımlanma Tarihi
7 Şubat 2011
Gönderilme Tarihi
11 Mart 2014
Kabul Tarihi
-
Yayımlandığı Sayı
Yıl 2010 Cilt: 44 Sayı: 6