Objectives: The aim of this prospective study was to evaluate the results of anatomical frame plate osteosynthesis in patients with Ada and Miller Type 2 or 4 scapula fractures.
Methods: Eleven Ada and Miller Type 2 or 4 scapula fractures in nine patients were treated with anatomical frame plate osteosynthesis. The mean follow-up time was 39.8 (12–77) months. The results were evaluated using the Herscovici score.
Results: No complications, such as neurovascular injury, postoperative hematoma, infection, delayed wound healing, implant failure, delayed union, or nonunion occurred. Based on the Herscovici score, the results were excellent.
Conclusion: Osteosynthesis with anatomical frame plates appears to be a safe method that allows early range of motion and that provides excellent results in Ada and Miller Type 2 or 4 scapula fractures.
Methods: Eleven Ada and Miller Type 2 or 4 scapula fractures in nine patients were treated with anatomical frame plate osteosynthesis. The mean follow-up time was 39.8 (12–77) months. The results were evaluated using the Herscovici score.
Results: No complications, such as neurovascular injury, postoperative hematoma, infection, delayed wound healing, implant failure, delayed union, or nonunion occurred. Based on the Herscovici score, the results were excellent.
Conclusion: Osteosynthesis with anatomical frame plates appears to be a safe method that allows early range of motion and that provides excellent results in Ada and Miller Type 2 or 4 scapula fractures.
Keywords
Ayrıntılar
Birincil Dil
İngilizce
Konular
Sağlık Kurumları Yönetimi
Bölüm
Araştırma Makalesi
Yayımlanma Tarihi
15 Temmuz 2011
Gönderilme Tarihi
11 Mart 2014
Kabul Tarihi
-
Yayımlandığı Sayı
Yıl 2011 Cilt: 45 Sayı: 3
APA
Esenkaya, I., & Unay, K. (2011). Anatomical frame plate osteosynthesis in Ada-Miller Type 2 or 4 scapula fractures. Acta Orthopaedica et Traumatologica Turcica, 45(3), 156-161. https://izlik.org/JA26PM79NZ
AMA
1.Esenkaya I, Unay K. Anatomical frame plate osteosynthesis in Ada-Miller Type 2 or 4 scapula fractures. Acta Orthopaedica et Traumatologica Turcica. 2011;45(3):156-161. https://izlik.org/JA26PM79NZ
Chicago
Esenkaya, Irfan, ve Koray Unay. 2011. “Anatomical frame plate osteosynthesis in Ada-Miller Type 2 or 4 scapula fractures”. Acta Orthopaedica et Traumatologica Turcica 45 (3): 156-61. https://izlik.org/JA26PM79NZ.
EndNote
Esenkaya I, Unay K (01 Temmuz 2011) Anatomical frame plate osteosynthesis in Ada-Miller Type 2 or 4 scapula fractures. Acta Orthopaedica et Traumatologica Turcica 45 3 156–161.
IEEE
[1]I. Esenkaya ve K. Unay, “Anatomical frame plate osteosynthesis in Ada-Miller Type 2 or 4 scapula fractures”, Acta Orthopaedica et Traumatologica Turcica, c. 45, sy 3, ss. 156–161, Tem. 2011, [çevrimiçi]. Erişim adresi: https://izlik.org/JA26PM79NZ
ISNAD
Esenkaya, Irfan - Unay, Koray. “Anatomical frame plate osteosynthesis in Ada-Miller Type 2 or 4 scapula fractures”. Acta Orthopaedica et Traumatologica Turcica 45/3 (01 Temmuz 2011): 156-161. https://izlik.org/JA26PM79NZ.
JAMA
1.Esenkaya I, Unay K. Anatomical frame plate osteosynthesis in Ada-Miller Type 2 or 4 scapula fractures. Acta Orthopaedica et Traumatologica Turcica. 2011;45:156–161.
MLA
Esenkaya, Irfan, ve Koray Unay. “Anatomical frame plate osteosynthesis in Ada-Miller Type 2 or 4 scapula fractures”. Acta Orthopaedica et Traumatologica Turcica, c. 45, sy 3, Temmuz 2011, ss. 156-61, https://izlik.org/JA26PM79NZ.
Vancouver
1.Irfan Esenkaya, Koray Unay. Anatomical frame plate osteosynthesis in Ada-Miller Type 2 or 4 scapula fractures. Acta Orthopaedica et Traumatologica Turcica [Internet]. 01 Temmuz 2011;45(3):156-61. Erişim adresi: https://izlik.org/JA26PM79NZ