Araştırma Makalesi

Anatomical frame plate osteosynthesis in Ada-Miller Type 2 or 4 scapula fractures

Cilt: 45 Sayı: 3 15 Temmuz 2011
  • Irfan Esenkaya
  • Koray Unay
PDF İndir
EN

Anatomical frame plate osteosynthesis in Ada-Miller Type 2 or 4 scapula fractures

Abstract

Objectives: The aim of this prospective study was to evaluate the results of anatomical frame plate osteosynthesis in patients with Ada and Miller Type 2 or 4 scapula fractures.
Methods: Eleven Ada and Miller Type 2 or 4 scapula fractures in nine patients were treated with anatomical frame plate osteosynthesis. The mean follow-up time was 39.8 (12–77) months. The results were evaluated using the Herscovici score.
Results: No complications, such as neurovascular injury, postoperative hematoma, infection, delayed wound healing, implant failure, delayed union, or nonunion occurred. Based on the Herscovici score, the results were excellent.
Conclusion: Osteosynthesis with anatomical frame plates appears to be a safe method that allows early range of motion and that provides excellent results in Ada and Miller Type 2 or 4 scapula fractures. 

Keywords

Ayrıntılar

Birincil Dil

İngilizce

Konular

Sağlık Kurumları Yönetimi

Bölüm

Araştırma Makalesi

Yazarlar

Irfan Esenkaya Bu kişi benim

Koray Unay Bu kişi benim

Yayımlanma Tarihi

15 Temmuz 2011

Gönderilme Tarihi

11 Mart 2014

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2011 Cilt: 45 Sayı: 3

Kaynak Göster

APA
Esenkaya, I., & Unay, K. (2011). Anatomical frame plate osteosynthesis in Ada-Miller Type 2 or 4 scapula fractures. Acta Orthopaedica et Traumatologica Turcica, 45(3), 156-161. https://izlik.org/JA26PM79NZ
AMA
1.Esenkaya I, Unay K. Anatomical frame plate osteosynthesis in Ada-Miller Type 2 or 4 scapula fractures. Acta Orthopaedica et Traumatologica Turcica. 2011;45(3):156-161. https://izlik.org/JA26PM79NZ
Chicago
Esenkaya, Irfan, ve Koray Unay. 2011. “Anatomical frame plate osteosynthesis in Ada-Miller Type 2 or 4 scapula fractures”. Acta Orthopaedica et Traumatologica Turcica 45 (3): 156-61. https://izlik.org/JA26PM79NZ.
EndNote
Esenkaya I, Unay K (01 Temmuz 2011) Anatomical frame plate osteosynthesis in Ada-Miller Type 2 or 4 scapula fractures. Acta Orthopaedica et Traumatologica Turcica 45 3 156–161.
IEEE
[1]I. Esenkaya ve K. Unay, “Anatomical frame plate osteosynthesis in Ada-Miller Type 2 or 4 scapula fractures”, Acta Orthopaedica et Traumatologica Turcica, c. 45, sy 3, ss. 156–161, Tem. 2011, [çevrimiçi]. Erişim adresi: https://izlik.org/JA26PM79NZ
ISNAD
Esenkaya, Irfan - Unay, Koray. “Anatomical frame plate osteosynthesis in Ada-Miller Type 2 or 4 scapula fractures”. Acta Orthopaedica et Traumatologica Turcica 45/3 (01 Temmuz 2011): 156-161. https://izlik.org/JA26PM79NZ.
JAMA
1.Esenkaya I, Unay K. Anatomical frame plate osteosynthesis in Ada-Miller Type 2 or 4 scapula fractures. Acta Orthopaedica et Traumatologica Turcica. 2011;45:156–161.
MLA
Esenkaya, Irfan, ve Koray Unay. “Anatomical frame plate osteosynthesis in Ada-Miller Type 2 or 4 scapula fractures”. Acta Orthopaedica et Traumatologica Turcica, c. 45, sy 3, Temmuz 2011, ss. 156-61, https://izlik.org/JA26PM79NZ.
Vancouver
1.Irfan Esenkaya, Koray Unay. Anatomical frame plate osteosynthesis in Ada-Miller Type 2 or 4 scapula fractures. Acta Orthopaedica et Traumatologica Turcica [Internet]. 01 Temmuz 2011;45(3):156-61. Erişim adresi: https://izlik.org/JA26PM79NZ