Biomechanical outcome of proximal femoral nail antirotation is superior to proximal femoral locking compression plate for reverse oblique intertrochanteric fractures: a biomechanical study of intertrochanteric fractures

Cilt: 49 Sayı: 4 19 Ağustos 2015
  • Jianxiong Ma
  • Jie Wang
  • Weiguo Xu
  • Jingtao Yu
  • Yang Yang
  • Xinlong Ma
PDF İndir
EN

Biomechanical outcome of proximal femoral nail antirotation is superior to proximal femoral locking compression plate for reverse oblique intertrochanteric fractures: a biomechanical study of intertrochanteric fractures

Abstract

Objective: Reverse obliquity intertrochanteric fractures are a challenge for orthopedic surgeons. The optimal internal fixation for repairing this type of unstable intertrochanteric fractures remains controversial. This study aimed to compare the biomechanical properties in axial load and cyclical axial load of proximal femoral nail antirotation (PFNA) and proximal femoral locking compression plate (PFLCP) for fixation of reverse obliquity intertrochanteric fractures.
Methods: Sixteen embalmed cadaver femurs were sawed to simulate reverse obliquity intertrochanteric fracture and instrumented with PFNA or PFLCP. Axial loads and axial cyclic loads were applied to the femoral head by an Instron tester. If the implant-femur constructs did not fail, axial failure load was added to the remaining implant-femur constructs.
Results: Mean axial stiffness for PFNA was 21.10% greater than that of PFLCP. Cyclic axial loading caused significantly less (p=0.022) mean irreversible deformation in PFNA (3.43 mm) than in PFLCP (4.34 mm). Significantly less (p=0.002) mean total deformation was detected in PFNA (6.16 mm) than in PFLCP (8.67 mm).
Conclusion: For fixing reverse obliquity intertrochanteric fractures, PFNA is superior to PFLCP under axial load.

 

DOI: 10.3944/AOTT.2015.14.0306



Keywords

Kaynakça

  1. Haidukewych GJ, Israel TA, Berry DJ. Reverse obliquity fractures of the intertrochanteric region of the femur. J Bone Joint Surg Am 2001;83-A:643–50.
  2. Min WK, Kim SY, Kim TK, Lee KB, Cho MR, Ha YC, et al. Proximal femoral nail for the treatment of reverse obliq- uity intertrochanteric fractures compared with gamma nail. J Trauma 2007;63:1054–60.
  3. Park SY, Yang KH, Yoo JH, Yoon HK, Park HW. The treatment of reverse obliquity intertrochanteric fractures with the intramedullary hip nail. J Trauma 2008;65:852–7.
  4. Honkonen SE, Vihtonen K, Järvinen MJ. Second-gener- ation cephalomedullary nails in the treatment of reverse obliquity intertrochanteric fractures of the proximal femur. Injury 2004;35:179–83.
  5. Mereddy P, Kamath S, Ramakrishnan M, Malik H, Don- nachie N. The AO/ASIF proximal femoral nail antirota- tion (PFNA): a new design for the treatment of unstable proximal femoral fractures. Injury 2009;40:428–32.
  6. Simmermacher RK, Ljungqvist J, Bail H, Hockertz T, Vochteloo AJ, Ochs U, et al. The new proximal femoral nail antirotation (PFNA) in daily practice: results of a multi- centre clinical study. Injury 2008;39:932–9.
  7. Sahin S, Ertürer E, Oztürk I, Toker S, Seçkin F, Akman S. Radiographic and functional results of osteosynthesis us- ing the proximal femoral nail antirotation (PFNA) in the treatment of unstable intertrochanteric femoral fractures. Acta Orthop Traumatol Turc 2010;44:127–34.
  8. Soucanye de Landevoisin E, Bertani A, Candoni P, Charpail C, Demortiere E. Proximal femoral nail antiro- tation (PFN-ATM) fixation of extra-capsular proximal femoral fractures in the elderly: retrospective study in 102 patients. Orthop Traumatol Surg Res 2012;98:288–95.

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

-

Yayımlanma Tarihi

19 Ağustos 2015

Gönderilme Tarihi

5 Ağustos 2015

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 1970 Cilt: 49 Sayı: 4

Kaynak Göster

APA
Ma, J., Wang, J., Xu, W., Yu, J., Yang, Y., & Ma, X. (2015). Biomechanical outcome of proximal femoral nail antirotation is superior to proximal femoral locking compression plate for reverse oblique intertrochanteric fractures: a biomechanical study of intertrochanteric fractures. Acta Orthopaedica et Traumatologica Turcica, 49(4), 426-432. https://doi.org/10.3944/AOTT.2015.14.0306
AMA
1.Ma J, Wang J, Xu W, Yu J, Yang Y, Ma X. Biomechanical outcome of proximal femoral nail antirotation is superior to proximal femoral locking compression plate for reverse oblique intertrochanteric fractures: a biomechanical study of intertrochanteric fractures. Acta Orthopaedica et Traumatologica Turcica. 2015;49(4):426-432. doi:10.3944/AOTT.2015.14.0306
Chicago
Ma, Jianxiong, Jie Wang, Weiguo Xu, Jingtao Yu, Yang Yang, ve Xinlong Ma. 2015. “Biomechanical outcome of proximal femoral nail antirotation is superior to proximal femoral locking compression plate for reverse oblique intertrochanteric fractures: a biomechanical study of intertrochanteric fractures”. Acta Orthopaedica et Traumatologica Turcica 49 (4): 426-32. https://doi.org/10.3944/AOTT.2015.14.0306.
EndNote
Ma J, Wang J, Xu W, Yu J, Yang Y, Ma X (01 Ağustos 2015) Biomechanical outcome of proximal femoral nail antirotation is superior to proximal femoral locking compression plate for reverse oblique intertrochanteric fractures: a biomechanical study of intertrochanteric fractures. Acta Orthopaedica et Traumatologica Turcica 49 4 426–432.
IEEE
[1]J. Ma, J. Wang, W. Xu, J. Yu, Y. Yang, ve X. Ma, “Biomechanical outcome of proximal femoral nail antirotation is superior to proximal femoral locking compression plate for reverse oblique intertrochanteric fractures: a biomechanical study of intertrochanteric fractures”, Acta Orthopaedica et Traumatologica Turcica, c. 49, sy 4, ss. 426–432, Ağu. 2015, doi: 10.3944/AOTT.2015.14.0306.
ISNAD
Ma, Jianxiong - Wang, Jie - Xu, Weiguo - Yu, Jingtao - Yang, Yang - Ma, Xinlong. “Biomechanical outcome of proximal femoral nail antirotation is superior to proximal femoral locking compression plate for reverse oblique intertrochanteric fractures: a biomechanical study of intertrochanteric fractures”. Acta Orthopaedica et Traumatologica Turcica 49/4 (01 Ağustos 2015): 426-432. https://doi.org/10.3944/AOTT.2015.14.0306.
JAMA
1.Ma J, Wang J, Xu W, Yu J, Yang Y, Ma X. Biomechanical outcome of proximal femoral nail antirotation is superior to proximal femoral locking compression plate for reverse oblique intertrochanteric fractures: a biomechanical study of intertrochanteric fractures. Acta Orthopaedica et Traumatologica Turcica. 2015;49:426–432.
MLA
Ma, Jianxiong, vd. “Biomechanical outcome of proximal femoral nail antirotation is superior to proximal femoral locking compression plate for reverse oblique intertrochanteric fractures: a biomechanical study of intertrochanteric fractures”. Acta Orthopaedica et Traumatologica Turcica, c. 49, sy 4, Ağustos 2015, ss. 426-32, doi:10.3944/AOTT.2015.14.0306.
Vancouver
1.Jianxiong Ma, Jie Wang, Weiguo Xu, Jingtao Yu, Yang Yang, Xinlong Ma. Biomechanical outcome of proximal femoral nail antirotation is superior to proximal femoral locking compression plate for reverse oblique intertrochanteric fractures: a biomechanical study of intertrochanteric fractures. Acta Orthopaedica et Traumatologica Turcica. 01 Ağustos 2015;49(4):426-32. doi:10.3944/AOTT.2015.14.0306