BibTex RIS Kaynak Göster

The comparison of the failure strength of meniscus arrows (absorbable fixation material) with different meniscal suturing techniques

Yıl 1997, Cilt: 31 Sayı: 5, 453 - 455, 11.09.2006

Öz

The importance of preserving meniscal tissue in the knee joint is well established recently. Functionally, the menisci have been shown to play a significant role in the knee. The capacity for meniscal healing and repair has also been well documented. The results of arthroscopic repair have been shown to be ar least as good for open repair. Then different arthroscopic meniscus repair techniques have been started to use. More recently, meniscus arrows (Biofix) whick are made of totally absorbable self- reinforced polylactic acid (SRPLA) have been used for meniscus repair. In this experimental study, we commpaired the failure strenths of meniscus arrows different meniscal suturing techniques (vertical and horizontal loop). Meniscal tears created on 15 human menisci which obtained from total knee arthroplasty application were repaired with meniscus arrows, vertical and horizontal loop sutures. Primary stabilities of these repairs were tested with meniscus arrows, vertical and horizontal loop sutures. Primary stabilities of these repairs were tested with İnstron tensometer. There were no significant difference between primary stabilities of each technique statistically. We think that the usage of meniscus arrows in meniscal repair has big advantages like easy application, less time comsuming and less neurovascular risk.

Meniskus okları (Arrows) ile farklı meniskus dikiş tekniklerinin primer stabilitelerinin karşılaştırılması

Yıl 1997, Cilt: 31 Sayı: 5, 453 - 455, 11.09.2006

Öz

Son yıllarda, meniskus dokusunu korumanın diz eklemi için nekadar önemli olduğu ortaya konulmuştur. Fonksiyonel olarak meniskusların dizdeki önemli rolü anlaşılmıştır. Menüskusun iyileşme kapasitesi ve tamir ile ilgili olumlu sonuçlar gösterilmiştir. Artoskopik meniskus tamirlerinin sonuçlarının açık tamir kadar iyi olduğu gösterilmiştir. Bunun üzerine değişik meniskus tamir teknikleri kullanıma sunulmuştur. Meniskus tamirinde son zamanlarda, vücud içinde tamamen emilebilen (self reinforced polyactic acid,. SR-PLA'den oluşan) meniskus okları (Arrows-Biofix) kullanılmaya başlandı. Bu çalışmada, meniskus oklanmn stabilitesini, iki değişik meniskus dikiş tekniği (horizontal ve vertikal loop) ile deneysel olarak karşılaştırdık. Diz protezi ameliyatı sırasında elde edilen 15 insan meniskusunda oluşturulan yırtıklar, meniskus okları ve dikiş (vertikal ve horizontal loop) ile tamir edildi. Bu tamirlerin stabiliteleri instron Tensometre cihazında ölçüldü. Sonuçlar arasında istatiksel olarak anlamlı fark bulunmadı. Meniskus tamirlerinde; teknik uygula-ması daha kolay, daha az zaman alan ve norovasküler riski daha az olan meniskus okları kullanılmasının daha avantajlı olduğunu düşünmekteyiz.

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Bölüm Deneysel Çalışma
Yazarlar

Sarper Cetinkaya Bu kişi benim

Burak Boynuk Bu kişi benim

Omer Taser Bu kişi benim

Yayımlanma Tarihi 11 Eylül 2006
Yayımlandığı Sayı Yıl 1997 Cilt: 31 Sayı: 5

Kaynak Göster

APA Cetinkaya, S., Boynuk, B., & Taser, O. (2006). The comparison of the failure strength of meniscus arrows (absorbable fixation material) with different meniscal suturing techniques. Acta Orthopaedica Et Traumatologica Turcica, 31(5), 453-455. https://doi.org/10.3944/aott.v31i5.2186
AMA Cetinkaya S, Boynuk B, Taser O. The comparison of the failure strength of meniscus arrows (absorbable fixation material) with different meniscal suturing techniques. Acta Orthopaedica et Traumatologica Turcica. Eylül 2006;31(5):453-455. doi:10.3944/aott.v31i5.2186
Chicago Cetinkaya, Sarper, Burak Boynuk, ve Omer Taser. “The Comparison of the Failure Strength of Meniscus Arrows (absorbable Fixation Material) With Different Meniscal Suturing Techniques”. Acta Orthopaedica Et Traumatologica Turcica 31, sy. 5 (Eylül 2006): 453-55. https://doi.org/10.3944/aott.v31i5.2186.
EndNote Cetinkaya S, Boynuk B, Taser O (01 Eylül 2006) The comparison of the failure strength of meniscus arrows (absorbable fixation material) with different meniscal suturing techniques. Acta Orthopaedica et Traumatologica Turcica 31 5 453–455.
IEEE S. Cetinkaya, B. Boynuk, ve O. Taser, “The comparison of the failure strength of meniscus arrows (absorbable fixation material) with different meniscal suturing techniques”, Acta Orthopaedica et Traumatologica Turcica, c. 31, sy. 5, ss. 453–455, 2006, doi: 10.3944/aott.v31i5.2186.
ISNAD Cetinkaya, Sarper vd. “The Comparison of the Failure Strength of Meniscus Arrows (absorbable Fixation Material) With Different Meniscal Suturing Techniques”. Acta Orthopaedica et Traumatologica Turcica 31/5 (Eylül 2006), 453-455. https://doi.org/10.3944/aott.v31i5.2186.
JAMA Cetinkaya S, Boynuk B, Taser O. The comparison of the failure strength of meniscus arrows (absorbable fixation material) with different meniscal suturing techniques. Acta Orthopaedica et Traumatologica Turcica. 2006;31:453–455.
MLA Cetinkaya, Sarper vd. “The Comparison of the Failure Strength of Meniscus Arrows (absorbable Fixation Material) With Different Meniscal Suturing Techniques”. Acta Orthopaedica Et Traumatologica Turcica, c. 31, sy. 5, 2006, ss. 453-5, doi:10.3944/aott.v31i5.2186.
Vancouver Cetinkaya S, Boynuk B, Taser O. The comparison of the failure strength of meniscus arrows (absorbable fixation material) with different meniscal suturing techniques. Acta Orthopaedica et Traumatologica Turcica. 2006;31(5):453-5.