Araştırma Makalesi

EFFECT OF SEPARATED ROTARY INSTRUMENTS ON THE APICAL MICROLEAKAGE OF ROOT CANAL FILLINGS

Cilt: 24 Sayı: 2 11 Şubat 2015
PDF İndir
EN TR

EFFECT OF SEPARATED ROTARY INSTRUMENTS ON THE APICAL MICROLEAKAGE OF ROOT CANAL FILLINGS

Öz

Aim: The aim of this in vitro study was to compare the effect of separated fragments from two different nickel titanium rotary instruments on microleakage of the root canal filling. Material and method: Extracted anterior teeth with single canal and straight roots were used. The teeth were divided into three groups. Group 1 and Group 3 (the control group) were shaped with ProTaper® rotary nickel-titanium (NiTi) files; Group 2 was shaped with Revo-S® rotary files. In Group 1, ProTaper® F3 files and in Group 2, Revo-S® 30/06 files, were broken in the apical one-third part of the root canals. All canals were obturated with gutta-percha and AH Plus sealer. After immersion in basic fuchsine stain solutions for 48 h, the roots were longitudinally sectioned. Digital photographs of the root sections were evaluated with image analysis software. Statistical analyses were performed with one way ANOVA and Tamhane test. Results: Microleakage of the control group was significantly less than Group 1 and Group 2. However, there was no statistically significant difference between the microleakage values of the groups separated ProTaper® or Revo-S® instruments. Conclusion: Separation of rotary NiTi instruments in the root canals negatively affected the apical seal of the root canal fillings, regardless of the instrument type

Anahtar Kelimeler

Kaynakça

  1. Hubscher W, Barbakow F, Peters OA. Root-canal preparation with FlexMaster: canal shapes analysed by micro-computed tomography. Int Endod J 2003;36:740-7.
  2. Ruddle CJ. Nonsurgical endodontic retreatment. J Calif Dent Assoc 2004;32:474-84.
  3. Iqbal MK, Kohli MR, Kim JS. A retrospective clinical study of incidence of root canal instrument separation in an endodontics graduate program: a PennEndo database study. J Endod 2006;32:1048- 52.
  4. Parashos P, Messer HH. Rotary NiTi instrument fracture and its consequences. J Endod 2006;32:1031-43.
  5. Al-Fouzan KS. Incidence of rotary ProFile instrument fracture and the potential for bypassing in vivo. Int Endod J 2003;36:864-7.
  6. Spili P, Parashos P, Messer HH. The impact of instrument fracture on outcome of endodontic treatment. J Endod 2005;31:845-50.
  7. Alapati SB, Brantley WA, Svec TA, et al. SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical use. J Endod 2005;31:40-3.
  8. Wu J, Lei G, Yan M, et al. Instrument separation analysis of multi-used ProTaper Universal rotary system during root canal therapy. J Endod 2011;37:758-63.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Diş Hekimliği

Bölüm

Araştırma Makalesi

Yazarlar

Hüseyin Ertaş Bu kişi benim

Banu İysal Bu kişi benim

Yayımlanma Tarihi

11 Şubat 2015

Gönderilme Tarihi

11 Şubat 2015

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2014 Cilt: 24 Sayı: 2

Kaynak Göster

APA
Ok, E., Ertaş, H., & İysal, B. (2015). EFFECT OF SEPARATED ROTARY INSTRUMENTS ON THE APICAL MICROLEAKAGE OF ROOT CANAL FILLINGS. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi, 24(2), 246-251. https://doi.org/10.17567/dfd.21241
AMA
1.Ok E, Ertaş H, İysal B. EFFECT OF SEPARATED ROTARY INSTRUMENTS ON THE APICAL MICROLEAKAGE OF ROOT CANAL FILLINGS. Ata Diş Hek Fak Derg. 2015;24(2):246-251. doi:10.17567/dfd.21241
Chicago
Ok, Evren, Hüseyin Ertaş, ve Banu İysal. 2015. “EFFECT OF SEPARATED ROTARY INSTRUMENTS ON THE APICAL MICROLEAKAGE OF ROOT CANAL FILLINGS”. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi 24 (2): 246-51. https://doi.org/10.17567/dfd.21241.
EndNote
Ok E, Ertaş H, İysal B (01 Şubat 2015) EFFECT OF SEPARATED ROTARY INSTRUMENTS ON THE APICAL MICROLEAKAGE OF ROOT CANAL FILLINGS. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi 24 2 246–251.
IEEE
[1]E. Ok, H. Ertaş, ve B. İysal, “EFFECT OF SEPARATED ROTARY INSTRUMENTS ON THE APICAL MICROLEAKAGE OF ROOT CANAL FILLINGS”, Ata Diş Hek Fak Derg, c. 24, sy 2, ss. 246–251, Şub. 2015, doi: 10.17567/dfd.21241.
ISNAD
Ok, Evren - Ertaş, Hüseyin - İysal, Banu. “EFFECT OF SEPARATED ROTARY INSTRUMENTS ON THE APICAL MICROLEAKAGE OF ROOT CANAL FILLINGS”. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi 24/2 (01 Şubat 2015): 246-251. https://doi.org/10.17567/dfd.21241.
JAMA
1.Ok E, Ertaş H, İysal B. EFFECT OF SEPARATED ROTARY INSTRUMENTS ON THE APICAL MICROLEAKAGE OF ROOT CANAL FILLINGS. Ata Diş Hek Fak Derg. 2015;24:246–251.
MLA
Ok, Evren, vd. “EFFECT OF SEPARATED ROTARY INSTRUMENTS ON THE APICAL MICROLEAKAGE OF ROOT CANAL FILLINGS”. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi, c. 24, sy 2, Şubat 2015, ss. 246-51, doi:10.17567/dfd.21241.
Vancouver
1.Evren Ok, Hüseyin Ertaş, Banu İysal. EFFECT OF SEPARATED ROTARY INSTRUMENTS ON THE APICAL MICROLEAKAGE OF ROOT CANAL FILLINGS. Ata Diş Hek Fak Derg. 01 Şubat 2015;24(2):246-51. doi:10.17567/dfd.21241

Cited By

Bu eser Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır. Tıklayınız.