Araştırma Makalesi

FEASIBILITY OF USING METAL PLATE CONNECTED TIMBERSTRAND LSL JOINTS IN THE TRUSS FABRICATION INDUSTRY

Cilt: 18 Sayı: 1 20 Nisan 2016
PDF İndir
EN

FEASIBILITY OF USING METAL PLATE CONNECTED TIMBERSTRAND LSL JOINTS IN THE TRUSS FABRICATION INDUSTRY

Abstract

Metal plate connectors enhance the load transfer by increasing the bearing area between wood member and the fastener. Because of having many advantages, metal plate connected (MPC) wood trusses have been widely used for over 50 years in many building applications especially in prefabricated homes. In this study, the possibility of using Timberstrand® laminated strand lumber (LSL) as a raw material was investigated. The behavior and the performance of metal plate connected Timberstrand connections loaded perpendicular to the grain in tension and shear at 0o, 45o and 90o orientations has been examined in accordance with ANSI TPI 1995 standards. According to the test results, Timberstrand joints performed better than solid southern pine joints in both tension (51%) and shear (10%) loading. This means that Timberstrand LSL has a very good potential for use in the truss fabrication industry.

Keywords

Kaynakça

  1. o ASTM D-1751-88, 1988. American Society for Testing and Materials Philadelphia, PA. Standard Test Methods for Mechanical Fasteners in Wood.
  2. o ANSI/TPI 1-1995, 1995. Design Specifications for Metal Plate Connected Wood Trusses.
  3. o Beamchek 1999. Structural Composite Lumber Values, http://www.beamchek.com/SCLvalues.htm (12/03/2016)
  4. o BOCA 1997. (Building Officials Code Administrators) Research Report of Alpine Wave Plate. 1997-4.
  5. o Denizli-Tankut, N., Smith, L. A., Smith, W. B., Tankut, A. N. 2004. Physical And Mechanical Properties of Laminated Strand Lumber Treated With Fire Retardant. Forest Products Journal, 54(6), 63-70.
  6. o Emerson, R. N., Fridley, K. J. 1996. Resistance of Metal Plate Connected Truss Joints to Dynamic Loading. Forest Products Journal, 46(5),83-90.
  7. o Foschi, R. O. 1977. Truss Plate Connections. Canadian Journal of Civil Engineering, 4(3),353-362
  8. o Gebremedhin, K. G., Jorgensen, M. C., Woelfel, C. B. 1992. Load-SIip Characteristics of Metal Plate Connected Wood Joints Tested in Tension and Shear. Wood and Fiber Science, 24(2),118-132.

Ayrıntılar

Birincil Dil

Türkçe

Konular

-

Bölüm

Araştırma Makalesi

Yazarlar

Saadettin Onat
BARTIN ÜNİVERSİTESİ
Türkiye

Yayımlanma Tarihi

20 Nisan 2016

Gönderilme Tarihi

23 Mart 2016

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2016 Cilt: 18 Sayı: 1

Kaynak Göster

APA
Onat, S. (2016). FEASIBILITY OF USING METAL PLATE CONNECTED TIMBERSTRAND LSL JOINTS IN THE TRUSS FABRICATION INDUSTRY. Bartın Orman Fakültesi Dergisi, 18(1), 1-12. https://izlik.org/JA23TP85FN


 

Bartin Orman Fakultesi Dergisi Editorship,

Bartin University, Faculty of Forestry, Dean Floor No:106, Agdaci District, 74100 Bartin-Turkey.

Tel: +90 (378) 223 5094, Fax: +90 (378) 223 5062,

E-mail: bofdergi@bartin.edu.tr