Araştırma Makalesi
BibTex RIS Kaynak Göster

FEASIBILITY OF USING METAL PLATE CONNECTED TIMBERSTRAND LSL JOINTS IN THE TRUSS FABRICATION INDUSTRY

Yıl 2016, Cilt: 18 Sayı: 1, 1 - 12, 20.04.2016

Öz

Metal plate connectors enhance the load transfer
by increasing the bearing area between wood member and the fastener. Because of
having many advantages, metal plate connected (MPC) wood trusses have been
widely used for over 50 years in many building applications especially in
prefabricated homes. In this study, the possibility of using Timberstrand®
laminated strand lumber (LSL) as a raw material was investigated. The behavior
and the performance of metal plate connected Timberstrand connections loaded perpendicular
to the grain in tension and shear at 0o, 45o and 90o orientations has been
examined in accordance with ANSI TPI 1995 standards. According to the test
results, Timberstrand joints performed better than solid southern pine joints
in both tension (51%) and shear (10%) loading. This means that Timberstrand LSL
has a very good potential for use in the truss fabrication industry.

Kaynakça

  • o ASTM D-1751-88, 1988. American Society for Testing and Materials Philadelphia, PA. Standard Test Methods for Mechanical Fasteners in Wood.
  • o ANSI/TPI 1-1995, 1995. Design Specifications for Metal Plate Connected Wood Trusses.
  • o Beamchek 1999. Structural Composite Lumber Values, http://www.beamchek.com/SCLvalues.htm (12/03/2016)
  • o BOCA 1997. (Building Officials Code Administrators) Research Report of Alpine Wave Plate. 1997-4.
  • o Denizli-Tankut, N., Smith, L. A., Smith, W. B., Tankut, A. N. 2004. Physical And Mechanical Properties of Laminated Strand Lumber Treated With Fire Retardant. Forest Products Journal, 54(6), 63-70.
  • o Emerson, R. N., Fridley, K. J. 1996. Resistance of Metal Plate Connected Truss Joints to Dynamic Loading. Forest Products Journal, 46(5),83-90.
  • o Foschi, R. O. 1977. Truss Plate Connections. Canadian Journal of Civil Engineering, 4(3),353-362
  • o Gebremedhin, K. G., Jorgensen, M. C., Woelfel, C. B. 1992. Load-SIip Characteristics of Metal Plate Connected Wood Joints Tested in Tension and Shear. Wood and Fiber Science, 24(2),118-132.
  • o Gebremedhin, K. G., Crovella, P. L. 1991. Load Distribution in Metal Plate Connectors of Tension Joints in Wood Trusses. Transactions of the ASAE. American society of Agricultural Engineers, 34 (1),281-287.
  • o Ginis, C. 1985. Tension and Shear Behavior of Laminated Veneer Lumber/Metal Plate Joints. Master's thesis. Department of Wood Products Engineering. SUNY-ESF Syracuse NY. Güntekin, E. 2009. Performance of Turkish Calabrian Pine (pinus brutia ten.) Timber Joints Constructed with Metal Plate Connectors. Wood Research, 54(3), 99-108.
  • o Holcomb, M. 1982. The Behavior of Laminated Veneer Lumber Fastened with Metal Plate Connectors and Loaded Perpendicular to The Grain. Master's thesis. Department of Wood Products Engineering. SUNY- ESF Syracuse NY.
  • o Hoover, C. C. 1996. An Overview of the Metal-Plate- Connected Wood Truss Industry, http://www.alpeng.com/alpine /Overview.htm (10/03/2016)
  • o Mc Alister, R. H., Faust, T. D. 1992. Load/Deflection Parameters for Metal Plate Connectors in Yellow Poplar and Sweetgum Structural Lumber. Forest Products Journal, 42 (3),60-64.
  • o Mac Arthy, M., Wolfe, R. W. 1987. Assessment of Truss Plate Performance Model Applied to Southern Pine Truss Joints. Res.Pap. FPL-RP-483. Madison, WI: USDA, Forest Products Laboratory. 13pp.
  • o Mc Kenna, J. 1979. An Evaluation of Laminated Veneer Lumber When Used with Metal Plate Connectors. Master's thesis. Department of Wood Products Engineering. SUNY-ESF Syracuse NY.
  • Wood Connections. Journal of Testing and Evaluation, 19(6), 421-428.
Yıl 2016, Cilt: 18 Sayı: 1, 1 - 12, 20.04.2016

Öz

Kaynakça

  • o ASTM D-1751-88, 1988. American Society for Testing and Materials Philadelphia, PA. Standard Test Methods for Mechanical Fasteners in Wood.
  • o ANSI/TPI 1-1995, 1995. Design Specifications for Metal Plate Connected Wood Trusses.
  • o Beamchek 1999. Structural Composite Lumber Values, http://www.beamchek.com/SCLvalues.htm (12/03/2016)
  • o BOCA 1997. (Building Officials Code Administrators) Research Report of Alpine Wave Plate. 1997-4.
  • o Denizli-Tankut, N., Smith, L. A., Smith, W. B., Tankut, A. N. 2004. Physical And Mechanical Properties of Laminated Strand Lumber Treated With Fire Retardant. Forest Products Journal, 54(6), 63-70.
  • o Emerson, R. N., Fridley, K. J. 1996. Resistance of Metal Plate Connected Truss Joints to Dynamic Loading. Forest Products Journal, 46(5),83-90.
  • o Foschi, R. O. 1977. Truss Plate Connections. Canadian Journal of Civil Engineering, 4(3),353-362
  • o Gebremedhin, K. G., Jorgensen, M. C., Woelfel, C. B. 1992. Load-SIip Characteristics of Metal Plate Connected Wood Joints Tested in Tension and Shear. Wood and Fiber Science, 24(2),118-132.
  • o Gebremedhin, K. G., Crovella, P. L. 1991. Load Distribution in Metal Plate Connectors of Tension Joints in Wood Trusses. Transactions of the ASAE. American society of Agricultural Engineers, 34 (1),281-287.
  • o Ginis, C. 1985. Tension and Shear Behavior of Laminated Veneer Lumber/Metal Plate Joints. Master's thesis. Department of Wood Products Engineering. SUNY-ESF Syracuse NY. Güntekin, E. 2009. Performance of Turkish Calabrian Pine (pinus brutia ten.) Timber Joints Constructed with Metal Plate Connectors. Wood Research, 54(3), 99-108.
  • o Holcomb, M. 1982. The Behavior of Laminated Veneer Lumber Fastened with Metal Plate Connectors and Loaded Perpendicular to The Grain. Master's thesis. Department of Wood Products Engineering. SUNY- ESF Syracuse NY.
  • o Hoover, C. C. 1996. An Overview of the Metal-Plate- Connected Wood Truss Industry, http://www.alpeng.com/alpine /Overview.htm (10/03/2016)
  • o Mc Alister, R. H., Faust, T. D. 1992. Load/Deflection Parameters for Metal Plate Connectors in Yellow Poplar and Sweetgum Structural Lumber. Forest Products Journal, 42 (3),60-64.
  • o Mac Arthy, M., Wolfe, R. W. 1987. Assessment of Truss Plate Performance Model Applied to Southern Pine Truss Joints. Res.Pap. FPL-RP-483. Madison, WI: USDA, Forest Products Laboratory. 13pp.
  • o Mc Kenna, J. 1979. An Evaluation of Laminated Veneer Lumber When Used with Metal Plate Connectors. Master's thesis. Department of Wood Products Engineering. SUNY-ESF Syracuse NY.
  • Wood Connections. Journal of Testing and Evaluation, 19(6), 421-428.
Toplam 16 adet kaynakça vardır.

Ayrıntılar

Bölüm Research Articles
Yazarlar

Saadettin Onat

Yayımlanma Tarihi 20 Nisan 2016
Yayımlandığı Sayı Yıl 2016 Cilt: 18 Sayı: 1

Kaynak Göster

APA Onat, S. (2016). FEASIBILITY OF USING METAL PLATE CONNECTED TIMBERSTRAND LSL JOINTS IN THE TRUSS FABRICATION INDUSTRY. Bartın Orman Fakültesi Dergisi, 18(1), 1-12.


Bartin Orman Fakultesi Dergisi Editorship,

Bartin University, Faculty of Forestry, Dean Floor No:106, Agdaci District, 74100 Bartin-Turkey.

Tel: +90 (378) 223 5094, Fax: +90 (378) 223 5062,

E-mail: bofdergi@gmail.com