DIODE ARRAY DETECTOR ELECTROSPRAY MASS SPECTROMETRY LIQUID CHROMATOGRAPHY AS APPLIED TO PARTIALLY OVERLAPPING PEAKS

Cilt: 2 Sayı: 2 1 Haziran 2000
  • Richard G Brereton
PDF İndir
EN

DIODE ARRAY DETECTOR ELECTROSPRAY MASS SPECTROMETRY LIQUID CHROMATOGRAPHY AS APPLIED TO PARTIALLY OVERLAPPING PEAKS

Öz

It is now common to obtain information from two or more detectors in HPLC simultaneously. Conventionally both DAD-HPLC and LC-MS data are obtained independently, often using quite different approaches, but there will be common features in both types of information. However, these will be distorted, for example, Electrospray MS profiles are typically more noisy and tailing compared to those from DAD-HPLC due to the different physical processes of passing from the chromatographic column to the detector. A method for obtaining and processing both types of data simultaneously is described. The analysis of isomers with identical molecular weights and similar elution times is particularly important in the pharmaceutical industry where small impurities can have a major influence on biological activity. The approach is illustrated by application to a mixture of 2- and 3- hydroxypyridine at varying levels of overlap.

Ayrıntılar

Birincil Dil

Türkçe

Konular

-

Bölüm

-

Yazarlar

Richard G Brereton Bu kişi benim

Yayımlanma Tarihi

1 Haziran 2000

Gönderilme Tarihi

1 Haziran 2000

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2000 Cilt: 2 Sayı: 2

Kaynak Göster

APA
Brereton, R. G. (2000). DIODE ARRAY DETECTOR ELECTROSPRAY MASS SPECTROMETRY LIQUID CHROMATOGRAPHY AS APPLIED TO PARTIALLY OVERLAPPING PEAKS. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi, 2(2), 34-34. https://izlik.org/JA59PZ93RA
AMA
1.Brereton RG. DIODE ARRAY DETECTOR ELECTROSPRAY MASS SPECTROMETRY LIQUID CHROMATOGRAPHY AS APPLIED TO PARTIALLY OVERLAPPING PEAKS. BAUN Fen. Bil. Enst. Dergisi. 2000;2(2):34-34. https://izlik.org/JA59PZ93RA
Chicago
Brereton, Richard G. 2000. “DIODE ARRAY DETECTOR ELECTROSPRAY MASS SPECTROMETRY LIQUID CHROMATOGRAPHY AS APPLIED TO PARTIALLY OVERLAPPING PEAKS”. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi 2 (2): 34-34. https://izlik.org/JA59PZ93RA.
EndNote
Brereton RG (01 Haziran 2000) DIODE ARRAY DETECTOR ELECTROSPRAY MASS SPECTROMETRY LIQUID CHROMATOGRAPHY AS APPLIED TO PARTIALLY OVERLAPPING PEAKS. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi 2 2 34–34.
IEEE
[1]R. G. Brereton, “DIODE ARRAY DETECTOR ELECTROSPRAY MASS SPECTROMETRY LIQUID CHROMATOGRAPHY AS APPLIED TO PARTIALLY OVERLAPPING PEAKS”, BAUN Fen. Bil. Enst. Dergisi, c. 2, sy 2, ss. 34–34, Haz. 2000, [çevrimiçi]. Erişim adresi: https://izlik.org/JA59PZ93RA
ISNAD
Brereton, Richard G. “DIODE ARRAY DETECTOR ELECTROSPRAY MASS SPECTROMETRY LIQUID CHROMATOGRAPHY AS APPLIED TO PARTIALLY OVERLAPPING PEAKS”. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi 2/2 (01 Haziran 2000): 34-34. https://izlik.org/JA59PZ93RA.
JAMA
1.Brereton RG. DIODE ARRAY DETECTOR ELECTROSPRAY MASS SPECTROMETRY LIQUID CHROMATOGRAPHY AS APPLIED TO PARTIALLY OVERLAPPING PEAKS. BAUN Fen. Bil. Enst. Dergisi. 2000;2:34–34.
MLA
Brereton, Richard G. “DIODE ARRAY DETECTOR ELECTROSPRAY MASS SPECTROMETRY LIQUID CHROMATOGRAPHY AS APPLIED TO PARTIALLY OVERLAPPING PEAKS”. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi, c. 2, sy 2, Haziran 2000, ss. 34-34, https://izlik.org/JA59PZ93RA.
Vancouver
1.Richard G Brereton. DIODE ARRAY DETECTOR ELECTROSPRAY MASS SPECTROMETRY LIQUID CHROMATOGRAPHY AS APPLIED TO PARTIALLY OVERLAPPING PEAKS. BAUN Fen. Bil. Enst. Dergisi [Internet]. 01 Haziran 2000;2(2):34-. Erişim adresi: https://izlik.org/JA59PZ93RA