BibTex RIS Kaynak Göster
Yıl 2001, Cilt: 3 Sayı: 1, 4 - 19, 01.06.2001

Öz

Total reflection X-Ray fluorescence analysis and application in biological system and textile industry

Yıl 2001, Cilt: 3 Sayı: 1, 4 - 19, 01.06.2001

Öz

Total reflection X-ray fluorescence (TXRF) spectroscopy is developed in recent 20 years and has been used for the determination of trace metal ions in various media such as water samples, geological samples etc. For the simultaneous determination of elements with atomic number greater than 11 in various matrices, TXRF is a universal and economic method. Today, TXRF as a micro trace element analysis technique takes place between the other spectroscopic techniques. In the present study, the determination of antimony, arsenic, lead, cadmium, chromium, cobalt, copper, nickel, mercury and zinc in the cloth samples produced in Kayseri-Turkey have been performed after extraction with artificial sweat solution and decomposition with nitric acid. TXRF technique is suitable for the determination of 7 trace elements, in the sweat extract and decompose solution except mercury and cadmium. In addition, it was observed that the element contents of textile samples are different from each other as ‘finger print type, TXRF-spectrum. This technique can also be used for the identification of textile sample in criminal investigation

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Diğer ID JA22DU98ED
Bölüm Araştırma Makalesi
Yazarlar

Mehmet Doğan Bu kişi benim

Mustafa Soylak Bu kişi benim

Latif Elçi Bu kişi benim

Alex von Bohlen Bu kişi benim

Yayımlanma Tarihi 1 Haziran 2001
Gönderilme Tarihi 1 Haziran 2001
Yayımlandığı Sayı Yıl 2001 Cilt: 3 Sayı: 1

Kaynak Göster

APA Doğan, M., Soylak, M., Elçi, L., Bohlen, A. v. (2001). Total reflection X-Ray fluorescence analysis and application in biological system and textile industry. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi, 3(1), 4-19.
AMA Doğan M, Soylak M, Elçi L, Bohlen Av. Total reflection X-Ray fluorescence analysis and application in biological system and textile industry. BAUN Fen. Bil. Enst. Dergisi. Haziran 2001;3(1):4-19.
Chicago Doğan, Mehmet, Mustafa Soylak, Latif Elçi, ve Alex von Bohlen. “Total Reflection X-Ray Fluorescence Analysis and Application in Biological System and Textile Industry”. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi 3, sy. 1 (Haziran 2001): 4-19.
EndNote Doğan M, Soylak M, Elçi L, Bohlen Av (01 Haziran 2001) Total reflection X-Ray fluorescence analysis and application in biological system and textile industry. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi 3 1 4–19.
IEEE M. Doğan, M. Soylak, L. Elçi, ve A. v. Bohlen, “Total reflection X-Ray fluorescence analysis and application in biological system and textile industry”, BAUN Fen. Bil. Enst. Dergisi, c. 3, sy. 1, ss. 4–19, 2001.
ISNAD Doğan, Mehmet vd. “Total Reflection X-Ray Fluorescence Analysis and Application in Biological System and Textile Industry”. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi 3/1 (Haziran 2001), 4-19.
JAMA Doğan M, Soylak M, Elçi L, Bohlen Av. Total reflection X-Ray fluorescence analysis and application in biological system and textile industry. BAUN Fen. Bil. Enst. Dergisi. 2001;3:4–19.
MLA Doğan, Mehmet vd. “Total Reflection X-Ray Fluorescence Analysis and Application in Biological System and Textile Industry”. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi, c. 3, sy. 1, 2001, ss. 4-19.
Vancouver Doğan M, Soylak M, Elçi L, Bohlen Av. Total reflection X-Ray fluorescence analysis and application in biological system and textile industry. BAUN Fen. Bil. Enst. Dergisi. 2001;3(1):4-19.