Performance evaluation of thin film a-Si photovoltaic system for Batman province
Öz
In this study one year data of grid connected system with thin film a-Si technologies in Batman province which has 2.16 kWp power and their module performance comparisons were evaluated according to external parameters. The data set covers from January until December 2016. The thin film a-Si PV system supplied 2.631 MWh energy to the grid during 2016. The final yield (Yf) this PV system ranged from 1.13 to 4.89 kWh/kWp/day and the performance ratio (PO) ranged from 53 to 78%. The effect of ambient and module temperatures on the system performance is calculated in the range 6% to 9%. It has also been determined that other parts of PV system affect system performance at various ratios.
Anahtar Kelimeler
Kaynakça
- Nebbia G., Twentytwenty-five, Futures, 33, 43-54 (2001).
- Pakma O., ZnO/CdS/CuIn(S,Se)2 heteroeklem güneş pillerinde admittans spektroskopisi ve akım iletim mekanizmaları, Yüksek Lisans Tezi, Muğla Üniversitesi (2002).
- Canete C., Carretero J. and Sidrach-de-Cardona M., Energy performance of different photovoltaic module technologies under outdoor conditions, Energy, 65, 295-302 (2014).
- Ferrada P., Araya F., Marzo A. and Fuentealba E., Performance analysis of photovoltaic system of two different technologies in a coastal desert climate zone of Chile, Solar Energy, 114, 356-363 (2015).
- Segado P. M., Carretero J., Sidrach-de-Cardona M., Models to predict the operating temperature of different photovoltaic modules in outdoor conditions, Progress in Photovoltaics, 23 (10), 1267-1282 (2015).
- Skplaki E. and Palyvos J.A., On the temperature dependence of photovoltaic module electrical performance: A review of efficiency/power correlations, Solar Energy, 83, 614-624 (2009).
Ayrıntılar
Birincil Dil
Türkçe
Konular
Mühendislik
Bölüm
Araştırma Makalesi
Yazarlar
Yayımlanma Tarihi
17 Temmuz 2018
Gönderilme Tarihi
4 Ekim 2017
Kabul Tarihi
7 Aralık 2017
Yayımlandığı Sayı
Yıl 2018 Cilt: 20 Sayı: 1
Cited By
Şebekeye Bağlı Üç Adet Fotovoltaik Enerji Santralinin PVsyst Programı ile Analizi; Kilis Örneği
El-Cezeri Fen ve Mühendislik Dergisi
https://doi.org/10.31202/ecjse.865649