Maximum relative floor displacements are one of the basic parameters that are limited by the regulations
in terms of safety for the regulations. According to the Regulation on the Turkish Earthquake Code (TEC)
2007 which are currently in force in our country, the limits and criteria of the relative floor drifts obtained
vary according to the TEC 2016 in draft. In this study, the "Effective Relative Floor Shift" account and
boundary conditions of both directives are compared in detail. It is understood that the permissible floor
folding limits allowed in the draft regulation are increased in the majority of the cases in general, in case
of the joint of the filler wall-frame joint, and in the case of the jointed design, two times higher than the
joint.
Relative storey drift TBDY2016 Elastic design spectral acceleration
Maksimum göreli kat ötelemeleri, yapıların yönetmeliklerce güvenlik açısından sınırlandırıldığı temel
parametrelerden biridir. Ülkemizde halen yürürlükte bulunan 2007 Deprem Bölgelerinde Yapılacak
Binalar Hakkında Yönetmeliğe göre, elde edilen göreli kat ötelemelerinin sınırları ve kriterleri, 2016
Türkiye Bina Deprem Yönetmelik taslağı ile değişmektedir. Bu çalışmada, her iki yönetmeliğin “Etkin
Göreli Kat Öteleme” hesabı ve sınır şartları detaylı olarak karşılaştırılmıştır. Taslak yönetmelikte izin
verilen göreli kat öteleme sınırlarının, dolgu duvar – çerçeve bağlantısının derzsiz olduğu durum için
genel olarak illerin büyük çoğunluğunda arttığı, derzli tasarımda ise derzsize göre iki kat yükseldiği
anlaşılmaktadır.
Göreli kat ötelemesi TBDY2016 Elastik tasarım spektral ivmesi
Bölüm | Makaleler |
---|---|
Yazarlar | |
Yayımlanma Tarihi | 15 Haziran 2017 |
Yayımlandığı Sayı | Yıl 2017 Cilt: 32 Sayı: 2 |