Öz

A portable and wireless surface electromyography device was developed for tracking the regional muscular activities of lumbar disc herniated patients. Previous studies showed that there is relation between paraspinal muscular activities and lumbar disc herniation. These studies encouraged us to develop a novel wireless surface electromyography device to follow muscular activities of lumbar disc herniated patients. Using such kind of wireless system in lumbar disc herniation studies leads to follow muscular activities practically. The overall system would lead to make diagnosis of lumbar disc herniation with a novel approach. The developed system consists of four major stages; amplification, filtering, A/D conversion, and the wireless communication stages. Bluetooth technology is chosen for communication between the proposed device and the computer. The designed device can be fully controlled within MATLAB software, and measured data can be directly streamed to computer environment. As a demonstration of the developed system, we also did certain signal processing operations in MATLAB by using measured surface electromyography signals

Anahtar Kelimeler

Kaynakça

  1. Geisser ME. Surface Electromyography and Low Back Pain, Biofeedback, Vol. 35, No. 1, 2007, pp.13-16. [2] Jordan J, Konstantinou K, O’Dowd
  2. http://clinicalevidence.bmj.com/ceweb/conditions/msd/1118/1118_background.jsp#REF4] 2009. J. Herniated Lumbar Disc,
  3. Skinner H. Current Diagnosis & Treatment in Orthopedics, New York: Appleton & Lange, 3rd Edition, 2003.
  4. Çevikcan B, Kara S. Bel Fıtığı Hastalığı Bulunan Bireylerin Bel Ve Karın Kası Fonksiyonlarının Elektromiyografik Analizi, Elektrik, Elektronik, Bilgisayar, Biyomedikal Mühendisliği XII.Ulusal Kongresi ve Fuarı, Eskişehir, 2007.
  5. Çakar Hİ, Kara S, Toker O. Bel Fıtığı Hastalığı Analizi için Portatif Elektromyiografi Cihazı Tasarımı, Biyomut 2010-15th National Meeting of Biomedical Engineering, Antalya, 2010.
  6. Çakar Hİ, Kara S, Toker O. Design of a Portable Electromyography Device for Back Herniated Patients, Biodevices 2010- 3rd International Conference on Biomedical Electronics and Devices, Valencia, 2010.
  7. De Luca CJ. Use of the Surface EMG Signal for Performance Evaluation of Back Muscles, Muscle&Nerve, Vol. 16, No. 2, 1993, pp.210-216.
  8. Haig AJ, Weismann, G, Haugh LD, Pope M, Grobler LJ. Prospective Evidence for Change in Paraspinal Muscle Activity after Herniated Nucleus Pulposus, Spine, Vol. 18, No. 7, 1993, pp.926-929.

Ayrıntılar

Birincil Dil

Türkçe

Konular

-

Bölüm

-

Yazarlar

Halil İbrahim Çakar Bu kişi benim

Sadık Kara Bu kişi benim

Onur Toker Bu kişi benim

Yayımlanma Tarihi

1 Mayıs 2015

Gönderilme Tarihi

1 Mayıs 2015

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2015 Cilt: 17 Sayı: 50

Kaynak Göster

APA
Çakar, H. İ., Kara, S., & Toker, O. (2015). LOMBER DİSK HERNİLİ HASTALAR İÇİN KABLOSUZ YÜZEY ELEKTROMİYOGRAFİ CİHAZ TASARIMI. Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen ve Mühendislik Dergisi, 17(50), 84-94. https://izlik.org/JA87XC92JY
AMA
1.Çakar Hİ, Kara S, Toker O. LOMBER DİSK HERNİLİ HASTALAR İÇİN KABLOSUZ YÜZEY ELEKTROMİYOGRAFİ CİHAZ TASARIMI. DEUFMD. 2015;17(50):84-94. https://izlik.org/JA87XC92JY
Chicago
Çakar, Halil İbrahim, Sadık Kara, ve Onur Toker. 2015. “LOMBER DİSK HERNİLİ HASTALAR İÇİN KABLOSUZ YÜZEY ELEKTROMİYOGRAFİ CİHAZ TASARIMI”. Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen ve Mühendislik Dergisi 17 (50): 84-94. https://izlik.org/JA87XC92JY.
EndNote
Çakar Hİ, Kara S, Toker O (01 Mayıs 2015) LOMBER DİSK HERNİLİ HASTALAR İÇİN KABLOSUZ YÜZEY ELEKTROMİYOGRAFİ CİHAZ TASARIMI. Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen ve Mühendislik Dergisi 17 50 84–94.
IEEE
[1]H. İ. Çakar, S. Kara, ve O. Toker, “LOMBER DİSK HERNİLİ HASTALAR İÇİN KABLOSUZ YÜZEY ELEKTROMİYOGRAFİ CİHAZ TASARIMI”, DEUFMD, c. 17, sy 50, ss. 84–94, May. 2015, [çevrimiçi]. Erişim adresi: https://izlik.org/JA87XC92JY
ISNAD
Çakar, Halil İbrahim - Kara, Sadık - Toker, Onur. “LOMBER DİSK HERNİLİ HASTALAR İÇİN KABLOSUZ YÜZEY ELEKTROMİYOGRAFİ CİHAZ TASARIMI”. Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen ve Mühendislik Dergisi 17/50 (01 Mayıs 2015): 84-94. https://izlik.org/JA87XC92JY.
JAMA
1.Çakar Hİ, Kara S, Toker O. LOMBER DİSK HERNİLİ HASTALAR İÇİN KABLOSUZ YÜZEY ELEKTROMİYOGRAFİ CİHAZ TASARIMI. DEUFMD. 2015;17:84–94.
MLA
Çakar, Halil İbrahim, vd. “LOMBER DİSK HERNİLİ HASTALAR İÇİN KABLOSUZ YÜZEY ELEKTROMİYOGRAFİ CİHAZ TASARIMI”. Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen ve Mühendislik Dergisi, c. 17, sy 50, Mayıs 2015, ss. 84-94, https://izlik.org/JA87XC92JY.
Vancouver
1.Halil İbrahim Çakar, Sadık Kara, Onur Toker. LOMBER DİSK HERNİLİ HASTALAR İÇİN KABLOSUZ YÜZEY ELEKTROMİYOGRAFİ CİHAZ TASARIMI. DEUFMD [Internet]. 01 Mayıs 2015;17(50):84-9. Erişim adresi: https://izlik.org/JA87XC92JY

Bu dergi, Creative Commons Atıf-GayriTicari 4.0 Uluslararası Lisansı (CC BY-NC 4.0) altında lisanslanmıştır.

download?token=eyJhdXRoX3JvbGVzIjpbXSwiZW5kcG9pbnQiOiJmaWxlIiwicGF0aCI6IjliNTAvMDBjMi8xZmIxLzY5MjZmZDIyOGE1NzgyLjA3MzU5MTk2LnBuZyIsImV4cCI6MTc2NDE2OTE1Nywibm9uY2UiOiJhZDRmNjNlNzdhOWYwOWQ4YTNjNGVmNGIxOTFlZWViNyJ9.4Dxgc9mc-p4Tyti8NTU5pxEfGUWeuJud1fPWxu2mUy8