This experimental study explores the effect of working current and pulse time on the performance of magnesium-calcium (Mg-0.8Ca) alloy, an unusual material, in die-sinking electrical discharge machining (EDM). The EDM performance was investigated by results of material removal rate (MRR), electrode wear ratio (EWR), electrode shape deformation and average surface roughness (Ra). Statistical methods, analysis of variance (ANOVA) and regression analysis were used for analytical explanation of the experimental results. It has been found that superior MRR and EWR results can be obtained in machining of magnesium-calcium alloys by EDM. However, surface roughness results of the alloy are not preferable after EDM
Die-sinking Electrical Discharge Machining MagnesiumCalciumAlloy biomedical
Ancak, tüm bu sonuçlara ek olarak Mg-Ca alaşımlarının geleneksel/alışılmış imalat yöntemleri işlenebilirlik edilmiştir. Tomac ve Tonnessen [5] bir magnezyum alaşımı (Mg-Al-Zn) için tornalama işleminde kesici takım yan kenarında meydana gelen yığıntı talaş oluşumunu Araştırmacıların bulguları aşağıdadır
Özet: Bu deneysel çalışma alışılmamış bir malzeme olan Dalma erozyon ile işleme magnezyum-kalsiyum (Mg-0.8Ca) alaşımının dalma elektro
Diğer ID | JA87HS92CV |
---|---|
Bölüm | Araştırma Makalesi |
Yazarlar | |
Yayımlanma Tarihi | 1 Mayıs 2018 |
Yayımlandığı Sayı | Yıl 2018 Cilt: 20 Sayı: 59 |
Dokuz Eylül Üniversitesi, Mühendislik Fakültesi Dekanlığı Tınaztepe Yerleşkesi, Adatepe Mah. Doğuş Cad. No: 207-I / 35390 Buca-İZMİR.