DEVELOPMENT OF A MAGNETORHEOLOGICAL GLOVE DESIGNED FOR HAND REHABILITATION

Yıl 2018, Cilt: 20 Sayı: 59, 545 - 554, 01.05.2018

Öz

The aim of hand rehabilitation is to maximize the remaining functional capacities of the hands and upper extremities of injured, operated, or diseased people. This study proposal aims at developing a rehabilitation device, in which magneto-rheological (MR) fluid is used to realize the fundamental isometric exercise motions in order to support the inadequate and weak muscles according to required amount of reaction. The viscosity of MR fluids increase in miliseconds and the fluid act like a solid. It again returns to its initial state as the application of magnetic field is stopped. The controllability of the rheological properties of MR fluid via magnetic field forms the starting point of this study: In the cases of hand rehabilitation, exercises needed to strengthen the muscles can be realized by changing the magnitude of the magnetic field of the box in which the MR fluid is stored. Solidification and softening of the MR fluid will force the hand in the glove, which will be placed inside the box. The study aimed in this study consists of a box with coils attached around and filled with MR fluid under a certain magnetic field. By altering the electromagnetic field, it will be possible to change the hardness of the MR fluid according to the patient’s state

Kaynakça

  • Maciejasz, P., Eschweiler, J., Gerlach-Hahn, K., Jansen-Troy, A. and Leonhardt, S. (2014), “A survey on robotic devices for upper limb rehabilitation”, neuroengineering and rehabilitation, Vol. 11 No. 1, p. 3.
  • D., Celestino, J., Charles, S.K., Lynch, D., Hogan, Neurorehabilitation: A Robot for Wrist Rehabilitation. IEEE Transactions on Neural Systems and Rehabilitation Engineering doi:10.1109/TNSRE.2007.903899
  • Campagne, A., 2007. Robot-mediated
  • Active Rehabilitation (ACRE) A user trial, in: Rehabilitation Robotics, 2007. ICORR
  • Conference on. IEEE, pp. 477–481 K., Le, V., Bobrow, J.E., Reinkensmeyer, D.J., 2008. A low cost parallel robot and trajectory optimization method for wrist and forearm rehabilitation using the Wii, in:
  • Biomechatronics, 2008. BioRob 2008. nd IEEE RAS & EMBS International
  • Conference on. IEEE, pp. 869–874. Development of wrist rehabilitation equipment using pneumatic parallel manipulator-Acquisition of PT’s motion and its execution for patient, in: Rehabilitation Robotics, 2009. ICORR
  • IEEE International Conference on. IEEE, pp. 34–39. Design, Implementation and Clinical Tests of a Wire-Based Robot for Neurorehabilitation. IEEE Transactions on Neural Systems and Rehabilitation Engineering doi:10.1109/TNSRE.2007.908560
  • Bachrach, B., Mayhew, D., 2008.
  • Development and evaluation of a gravity compensated training environment for robotic rehabilitation of post-stroke reaching, in: Biomedical Robotics and Biomechatronics, 2008. BioRob 2008. nd IEEE RAS & EMBS International
  • Conference on. IEEE, pp. 205–210. F.C.T. (2006), “Kinematic Design to
  • Improve Ergonomics in Human Machine Interaction”, IEEE Transactions on Neural Systems and Rehabilitation Engineering, Vol. 14 No. 4, pp. 456–469. Q. (2009), “Developing a whole-arm exoskeleton robot with hand opening and closing mechanism for upper limb stroke rehabilitation”, Rehabilitation
  • Robotics, 2009. ICORR 2009. IEEE
  • International Conference on, IEEE, pp. –765. (2007), Exoskeleton
  • Transactions on Mechatronics, Vol. 12 No. 4, pp. 408–417. (2009), Advances in Robotics Research,
  • Springer Berlin Heidelberg, Berlin, Heidelberg, http://link.springer.com/10.1007/978- at: magnetorheological
  • Oda, K., Isozumi, S., Ohyama, Y., Winter, S.H., Bouzit, M., 2007. Feedback Glove. IEEE
  • Andres F. Restrepo-Alvarez, Study and

MANYETOREOLOJİK SIVI İLE EL REHABİLİTASYON CİHAZİ TASARIMI VE ÜRETİMİ

Yıl 2018, Cilt: 20 Sayı: 59, 545 - 554, 01.05.2018

Öz

Bu çalışmanın çıkış noktası, MR akışkanların reolojik özelliklerinin manyetik alan ile kontrol edilmesidir. Bu doğrultuda rehabilitasyon gerektiren el ve üst ekstremite vakalarında kasların güçlendirilmesini sağlayacak egzersiz hareketleri, manyetoreolojik sıvının hapsedildiği manyetik alan içerisinde gerçekleştirilebilmektedir. Manyetik alan ile MR sıvısının katılaşması veya yumuşamasıyla el ve parmak hareketleri güçlendirilerek kas gücünün ve fonksiyonel hareketinin arttırılması sağlanmaktadır. Bu çalışmada geliştirilen cihaz, içi MR sıvısı ile dolu olan ve çevresindeki sargılar ile üzerine manyetik alanın uygulandığı bir kutudan oluşmaktadır. Elektrik akımının kontrolüyle MR sıvının sertlik derecesi, hastanın gelişimine göre ayarlanabilmektedir

Kaynakça

  • Maciejasz, P., Eschweiler, J., Gerlach-Hahn, K., Jansen-Troy, A. and Leonhardt, S. (2014), “A survey on robotic devices for upper limb rehabilitation”, neuroengineering and rehabilitation, Vol. 11 No. 1, p. 3.
  • D., Celestino, J., Charles, S.K., Lynch, D., Hogan, Neurorehabilitation: A Robot for Wrist Rehabilitation. IEEE Transactions on Neural Systems and Rehabilitation Engineering doi:10.1109/TNSRE.2007.903899
  • Campagne, A., 2007. Robot-mediated
  • Active Rehabilitation (ACRE) A user trial, in: Rehabilitation Robotics, 2007. ICORR
  • Conference on. IEEE, pp. 477–481 K., Le, V., Bobrow, J.E., Reinkensmeyer, D.J., 2008. A low cost parallel robot and trajectory optimization method for wrist and forearm rehabilitation using the Wii, in:
  • Biomechatronics, 2008. BioRob 2008. nd IEEE RAS & EMBS International
  • Conference on. IEEE, pp. 869–874. Development of wrist rehabilitation equipment using pneumatic parallel manipulator-Acquisition of PT’s motion and its execution for patient, in: Rehabilitation Robotics, 2009. ICORR
  • IEEE International Conference on. IEEE, pp. 34–39. Design, Implementation and Clinical Tests of a Wire-Based Robot for Neurorehabilitation. IEEE Transactions on Neural Systems and Rehabilitation Engineering doi:10.1109/TNSRE.2007.908560
  • Bachrach, B., Mayhew, D., 2008.
  • Development and evaluation of a gravity compensated training environment for robotic rehabilitation of post-stroke reaching, in: Biomedical Robotics and Biomechatronics, 2008. BioRob 2008. nd IEEE RAS & EMBS International
  • Conference on. IEEE, pp. 205–210. F.C.T. (2006), “Kinematic Design to
  • Improve Ergonomics in Human Machine Interaction”, IEEE Transactions on Neural Systems and Rehabilitation Engineering, Vol. 14 No. 4, pp. 456–469. Q. (2009), “Developing a whole-arm exoskeleton robot with hand opening and closing mechanism for upper limb stroke rehabilitation”, Rehabilitation
  • Robotics, 2009. ICORR 2009. IEEE
  • International Conference on, IEEE, pp. –765. (2007), Exoskeleton
  • Transactions on Mechatronics, Vol. 12 No. 4, pp. 408–417. (2009), Advances in Robotics Research,
  • Springer Berlin Heidelberg, Berlin, Heidelberg, http://link.springer.com/10.1007/978- at: magnetorheological
  • Oda, K., Isozumi, S., Ohyama, Y., Winter, S.H., Bouzit, M., 2007. Feedback Glove. IEEE
  • Andres F. Restrepo-Alvarez, Study and
Toplam 18 adet kaynakça vardır.

Ayrıntılar

Diğer ID JA77BN84AB
Bölüm Araştırma Makalesi
Yazarlar

Aysun Baltacı Bu kişi benim

Hasan Aykut Aydın Bu kişi benim

Özgen Tonay Bu kişi benim

Barış Oğuz Gürses Bu kişi benim

Sercan Sabancı Bu kişi benim

Mustafa Ertekin Bu kişi benim

Seçkin Erden Bu kişi benim

Yayımlanma Tarihi 1 Mayıs 2018
Yayımlandığı Sayı Yıl 2018 Cilt: 20 Sayı: 59

Kaynak Göster

APA Baltacı, A., Aydın, H. A., Tonay, Ö., Gürses, B. O., vd. (2018). MANYETOREOLOJİK SIVI İLE EL REHABİLİTASYON CİHAZİ TASARIMI VE ÜRETİMİ. Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen Ve Mühendislik Dergisi, 20(59), 545-554.
AMA Baltacı A, Aydın HA, Tonay Ö, Gürses BO, Sabancı S, Ertekin M, Erden S. MANYETOREOLOJİK SIVI İLE EL REHABİLİTASYON CİHAZİ TASARIMI VE ÜRETİMİ. DEUFMD. Mayıs 2018;20(59):545-554.
Chicago Baltacı, Aysun, Hasan Aykut Aydın, Özgen Tonay, Barış Oğuz Gürses, Sercan Sabancı, Mustafa Ertekin, ve Seçkin Erden. “MANYETOREOLOJİK SIVI İLE EL REHABİLİTASYON CİHAZİ TASARIMI VE ÜRETİMİ”. Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen Ve Mühendislik Dergisi 20, sy. 59 (Mayıs 2018): 545-54.
EndNote Baltacı A, Aydın HA, Tonay Ö, Gürses BO, Sabancı S, Ertekin M, Erden S (01 Mayıs 2018) MANYETOREOLOJİK SIVI İLE EL REHABİLİTASYON CİHAZİ TASARIMI VE ÜRETİMİ. Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen ve Mühendislik Dergisi 20 59 545–554.
IEEE A. Baltacı, “MANYETOREOLOJİK SIVI İLE EL REHABİLİTASYON CİHAZİ TASARIMI VE ÜRETİMİ”, DEUFMD, c. 20, sy. 59, ss. 545–554, 2018.
ISNAD Baltacı, Aysun vd. “MANYETOREOLOJİK SIVI İLE EL REHABİLİTASYON CİHAZİ TASARIMI VE ÜRETİMİ”. Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen ve Mühendislik Dergisi 20/59 (Mayıs 2018), 545-554.
JAMA Baltacı A, Aydın HA, Tonay Ö, Gürses BO, Sabancı S, Ertekin M, Erden S. MANYETOREOLOJİK SIVI İLE EL REHABİLİTASYON CİHAZİ TASARIMI VE ÜRETİMİ. DEUFMD. 2018;20:545–554.
MLA Baltacı, Aysun vd. “MANYETOREOLOJİK SIVI İLE EL REHABİLİTASYON CİHAZİ TASARIMI VE ÜRETİMİ”. Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen Ve Mühendislik Dergisi, c. 20, sy. 59, 2018, ss. 545-54.
Vancouver Baltacı A, Aydın HA, Tonay Ö, Gürses BO, Sabancı S, Ertekin M, Erden S. MANYETOREOLOJİK SIVI İLE EL REHABİLİTASYON CİHAZİ TASARIMI VE ÜRETİMİ. DEUFMD. 2018;20(59):545-54.

Dokuz Eylül Üniversitesi, Mühendislik Fakültesi Dekanlığı Tınaztepe Yerleşkesi, Adatepe Mah. Doğuş Cad. No: 207-I / 35390 Buca-İZMİR.