Use of Ultrasound-Measured Optic Nerve Sheath Diameter in the Emergency Department to Differentiate Hypertensive Emergency and Urgency
Öz
Objectives: Hypertensive patients may present with varying degrees of clinical severity and target organ damage (TOD). Bedside ultrasound measurement of optic nerve sheath diameter (ONSD) is a rapid and non-invasive bedside imaging method increasingly used in emergency settings. The primary aim of this study was to evaluate the association between baseline ONSD and clinical severity in hypertensive patients presenting to the emergency department (ED).
Methods: This prospective, single-center, observational study included adult patients presenting to the ED with hypertension and suspected acute TOD, consistent with hypertensive emergency (HE). Demographic and clinical data, blood pressure measurements, and pre- and post-treatment ONSD values were recorded. The associations between ONSD, TOD, treatment response, and hospitalization were analyzed, and the discriminative ability of ONSD for clinical outcomes was assessed using receiver operating characteristic (ROC) analysis.
Results: A total of 113 hypertensive patients were included in the study. ONSD values were significantly higher in patients with TOD compared to those without (4.88±0.76 mm vs. 4.45±0.46 mm, p=0.007). A significant decrease in ONSD values was observed after antihypertensive treatment (p<0.001). ROC analysis revealed that the ONSD threshold value associated with HE was 4.62 mm (sensitivity: 69%, specificity: 69%), and for predicting hospitalization it was 4.57 mm (sensitivity: 65%, specificity: 60%). A moderate positive correlation was found between ONSD and age, systolic and diastolic blood pressure, and TOD.
Conclusion: Bedside ultrasound measurement of ONSD may serve as an adjunctive, non-invasive parameter associated with clinical severity and hospitalization requirement in hypertensive patients presenting to the ED.
Anahtar Kelimeler
Etik Beyan
The study was conducted with the approval of Afyonkarahisar Health Sciences University Non-Interventional Ethics Committee (Meeting Date: 03.02.2023, Decision No: 2023/2, Ethics Committee Code: 2011-KAEK-2). A signed informed consent form was secured from every individual who participated in the research. The Helsinki Declaration was followed as the guideline in this study. This study was derived from the medical specialty thesis of Dr. Hüseyin Aldemir.
Kaynakça
- 1.World Health Organization. Hypertension. 2023[cited 2025 Sep 8]. Available from:https://www.who.int/news-room/fact-sheets/detail/hypertension.
- 2.Sözmen K, Ergör G, Ünal B. Hipertansiyon sıklığı,farkındalığı, tedavi alma ve kan basıncı kontrolünüetkileyen etmenler. Dicle Med J. 2015;42(2):199-207.doi: 10.5798/diclemedj.0921.2015.02.0558
- 3.Miller J, McNaughton C, Joyce K, Binz S, Levy P.Hypertension management in emergencydepartments. Am J Hypertens. 2020;33(10):927–34.doi: 10.1093/ajh/hpaa068
- 4.Öksüz F, Yayla C. SCORE Kardiyovasküler riskpuanlama sistemi ile non-dipper hipertansiyonarasındaki ilişki. Dicle Med J. 2018;45(4):379-86.doi: 10.5798/dicletip.497883
- 5.Miller JB, Hrabec D, Krishnamoorthy V, Kinni H,Brook RD. Evaluation and management ofhypertensive emergency. BMJ. 2024;386:e077205.doi: 10.1136/bmj-2023-077205
- 6.Alley WD, Schick MA. Hypertensive emergency.[Internet]. Treasure Island (FL): StatPearlsPublishing; 2023 Jul- [updated 2023 Jul 24; cited2025 Sep 8]. Available from: https://www.ncbi.nlm.nih.gov/books/NBK470371/
- 7.da Costa MM, Sousa ALL, Correia MC, et al.Intracranial pressure waveform in patients withessential hypertension. Front Cardiovasc Med.2023;10:1288080. doi:10.3389/fcvm.2023.1288080
- 8.Tavakoli S, Peitz G, Ares W, Hafeez S, Grandhi R.Complications of invasive intracranial pressuremonitoring devices in neurocritical care. NeurosurgFocus. 2017;43(5):E6. doi:10.3171/2017.8.FOCUS17450
Ayrıntılar
Birincil Dil
İngilizce
Konular
Sağlık Kurumları Yönetimi, Tıp Eğitimi, Sağlık Hizmetleri ve Sistemleri (Diğer)
Bölüm
Araştırma Makalesi
Yayımlanma Tarihi
5 Haziran 2026
Gönderilme Tarihi
2 Şubat 2026
Kabul Tarihi
24 Nisan 2026
Yayımlandığı Sayı
Yıl 2026 Cilt: 53 Sayı: 2
APA
Aldemir, H., Özdinç, Ş., & Soyugüzel, M. (2026). Use of Ultrasound-Measured Optic Nerve Sheath Diameter in the Emergency Department to Differentiate Hypertensive Emergency and Urgency. Dicle Medical Journal, 53(2), 371-379. https://doi.org/10.5798/dicletip.1964445
AMA
1.Aldemir H, Özdinç Ş, Soyugüzel M. Use of Ultrasound-Measured Optic Nerve Sheath Diameter in the Emergency Department to Differentiate Hypertensive Emergency and Urgency. diclemedj. 2026;53(2):371-379. doi:10.5798/dicletip.1964445
Chicago
Aldemir, Hüseyin, Şerife Özdinç, ve Mehmet Soyugüzel. 2026. “Use of Ultrasound-Measured Optic Nerve Sheath Diameter in the Emergency Department to Differentiate Hypertensive Emergency and Urgency”. Dicle Medical Journal 53 (2): 371-79. https://doi.org/10.5798/dicletip.1964445.
EndNote
Aldemir H, Özdinç Ş, Soyugüzel M (01 Haziran 2026) Use of Ultrasound-Measured Optic Nerve Sheath Diameter in the Emergency Department to Differentiate Hypertensive Emergency and Urgency. Dicle Medical Journal 53 2 371–379.
IEEE
[1]H. Aldemir, Ş. Özdinç, ve M. Soyugüzel, “Use of Ultrasound-Measured Optic Nerve Sheath Diameter in the Emergency Department to Differentiate Hypertensive Emergency and Urgency”, diclemedj, c. 53, sy 2, ss. 371–379, Haz. 2026, doi: 10.5798/dicletip.1964445.
ISNAD
Aldemir, Hüseyin - Özdinç, Şerife - Soyugüzel, Mehmet. “Use of Ultrasound-Measured Optic Nerve Sheath Diameter in the Emergency Department to Differentiate Hypertensive Emergency and Urgency”. Dicle Medical Journal 53/2 (01 Haziran 2026): 371-379. https://doi.org/10.5798/dicletip.1964445.
JAMA
1.Aldemir H, Özdinç Ş, Soyugüzel M. Use of Ultrasound-Measured Optic Nerve Sheath Diameter in the Emergency Department to Differentiate Hypertensive Emergency and Urgency. diclemedj. 2026;53:371–379.
MLA
Aldemir, Hüseyin, vd. “Use of Ultrasound-Measured Optic Nerve Sheath Diameter in the Emergency Department to Differentiate Hypertensive Emergency and Urgency”. Dicle Medical Journal, c. 53, sy 2, Haziran 2026, ss. 371-9, doi:10.5798/dicletip.1964445.
Vancouver
1.Hüseyin Aldemir, Şerife Özdinç, Mehmet Soyugüzel. Use of Ultrasound-Measured Optic Nerve Sheath Diameter in the Emergency Department to Differentiate Hypertensive Emergency and Urgency. diclemedj. 01 Haziran 2026;53(2):371-9. doi:10.5798/dicletip.1964445