BibTex RIS Kaynak Göster

Comparison of anterior segment parameters with pentacam according to age in emmetropic eyes

Yıl 2013, , 627 - 631, 01.12.2013
https://doi.org/10.5798/diclemedj.0921.2013.04.0345

Öz

Objective: It was aimed to compare anterior segment parameters obtained by rotating Scheimpflug camera system according to age groups. Methods: 290 eyes of 145 emmetropic subjects were included in the study. Subjects were divided in three age groups. Group 1 comprised the subjects age up to 20 years, Group 2 comprised the subjects age between 21 and 40 and Group 3 comprised the subjects between 41 years and older. In all subjects, flat keratometry (K1), steep keratometry (K2), mean corneal power (Km), maximum keratometry (Kmax), central corneal thickness (CCT), apex corneal thickness (ACT), thinnest corneal thickness (TCT), anterior chamber volume (ACV) and anterior chamber depth (ACD) were obtained by using rotating Scheimpflug camera system. To eliminate operator dependent variables, automatic release mode was used. All measurements were obtained by the same examiner. Results: The study included 72 female and 73 male subjects. The mean age of the subjects was 31.37±12.29 years (range, 8-65). There were no significant differences in keratometric values between age groups. There was significant difference between Groups 1 and 3 and Groups 2 and 3 in the mean CCT, ACT and TCT (p

Kaynakça

  • Oltulu R, Şahin A. Keratokonuslu Gözlerde ön segment para- metrelerinin pentacam cihazı ile değerlendirilmesi. Turkiye Klinikleri J Ophthalmol 2011;20:79-82.
  • Yan PS, Lin HT, Wang QL, Zhang ZP. Anterior segment variations with age and accommodation demonstrated by slit-lamp-adapted optical coherence tomography. Ophthal- mology 2010;117:2301-2307.
  • Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and me- ta-analysis approach. Surv Ophthalmol 2000;44:367-408.
  • Kubaloğlu A, Sari ES, Cinar Y, et al. Intrastromal corneal ring segment implantation for the treatment of keratoconus. Cornea 2011;30:11-17.
  • Cinar Y, Cingu AK, Sahin A, et al. Intraoperative corneal thickness measurements during corneal collagen cross-link- ing with isotonic riboflavin solution without dextran in cor- neal ectasia. Cutan Ocul Toxicol 2013. Basım aşamasında, DOI: 10.3109/15569527.2013.793700
  • Khoramnia R, Rabsilber TM, Auffarth GU. Central and pe- ripheral pachymetry measurements according to age using the Pentacam rotating Scheimpflug camera. J Cataract Re- fract Surg 2007;33:830-836.
  • Rufer F, Schroder A, Bader C, Erb C. Age-related changes in central and peripheral corneal thickness: determination of normal values with the Orbscan II topography system. Cornea 2007;26:1-5.
  • Çinal A, Topuz H, Şimşek Ş, Demirok A. Age and corneal topography. MN Oftalmoloji Dergisi 2002;9:230-233.
  • Emre S, Doğanay S, Yoloğlu S. Sağlıklı Bireylerde Pentacam ile Elde Edilen Ön Segment Parametreleri Üzerine Yaşın Etkisinin Degerlendirilmesi. T Oft Gaz 2008;38:452-458.
  • Jonsson M, Markstrom K, Behndig A. Slit-scan tomog- raphy evaluation of the anterior chamber and corneal configurations at different ages. Acta Ophthalmol Scand 2006;84:116-120.
  • Ambrosio R, Alonso RS, Luz A, Coca Velarde LG. Corneal- thickness spatial profile and corneal-volume distribution: tomographic indices to detect keratoconus. J Cataract Re- fract Surg 2006;32:1851-1859.
  • Rabsilber TM, Khoramnia R, Auffarth GU. Anterior cham- ber measurements using Pentacam rotating Scheimpflug camera. J Cataract Refract Surg 2006;32:456-459.
  • Randleman JB, Woodward M, Lynn MJ, Stulting RD. Risk assessment for ectasia after corneal refractive surgery. Oph- thalmology 2008;115:37-50.
  • Muallem MS, Yoo SH, Romano AC, et al. Flap and stromal bed thickness in laser in situ keratomileusis enhancement. J Cataract Refract Surg 2004;30:2295-302.
  • Sari ES, Pinero DP, Kubaloğlu A, et al. Toric implantable collamer lens for moderate to high myopic astigmatism: 3-year follow-up. Graefes Arch Clin Exp Ophthalmol 2013;251:1413-1422.
  • Olsen T, Corydon L, Gimbel H. Intraocular lens power cal- culation with an improved anterior chamber depth predic- tion algorithm. J Cataract Refract Surg 1995;21:313-319.
  • Lowe RF. Anterior lens displacement with age. Br J Oph- thalmol 1970;54:117-121.
  • Özer A, Şorabatur M, Şahin A, ve ark. Ön Kamara Derin- liginin Korneal Topografi ve Keratometre Yöntemleri ile Degerlendirilmesi. Glokom-Katarakt 2006;1:93-96.

Emetropik gözlerde pentacam ile ön segment parametrelerinin yaş gruplarına göre karşılaştırılması

Yıl 2013, , 627 - 631, 01.12.2013
https://doi.org/10.5798/diclemedj.0921.2013.04.0345

Öz

Amaç: Emetrop olgularda Pentacam HR cihazı ile alınan ön segment parametrelerini yaş gruplarına göre karşılaştırılması amaçlandı. Yöntemler: Çalışmaya katılan 145 emetrop olgunun 290 gözüne ait Pentacam parametreleri değerlendirildi. Olgular yaşlarına göre üç gruba ayrıldı. Grup 1, yirmi yaşına kadar olan olguları, grup 2, 21-40 yaş arası olan olguları ve grup 3, ise 41 yaşından büyük olan olguları içermekteydi. Tüm olguların düz keratometri (K1), dik keratometri (K2), ortalama kornea kırıcılığı (Km), maksimum keratometri (Kmax), merkezi kornea kalınlığı (MKK), apeks kornea kalınlığı (AKK), en ince kornea kalınlığı (EİKK), ön kamara hacmi (ÖKH) ve ön kamara derinliği (ÖKD) değerlendirmeye alındı. Ölçümler sırasında kullanıcıya bağlı değişkenleri ekarte etmek amacıyla otomatik çekim modu kullanıldı ve tüm çekimler aynı araştırmacı tarafından yapıldı. Bulgular: Olguların 72'si kadın, 73'ü ise erkekti ve ortalama yaşları 31,37±12,29 yıl (8-65 yıl) idi. Keratometrik değerler açısından yaş grupları arasında anlamlı farklılık saptanmadı. Ortalama MKK, AKK ve EİKK değerleri açısından grup 1-3 ve grup 2-3 arasında, ortalama ÖKH ve ÖKD değerleri arasından ise tüm gruplarda istatistiksel olarak anlamlı farklılık mevcuttu (p

Kaynakça

  • Oltulu R, Şahin A. Keratokonuslu Gözlerde ön segment para- metrelerinin pentacam cihazı ile değerlendirilmesi. Turkiye Klinikleri J Ophthalmol 2011;20:79-82.
  • Yan PS, Lin HT, Wang QL, Zhang ZP. Anterior segment variations with age and accommodation demonstrated by slit-lamp-adapted optical coherence tomography. Ophthal- mology 2010;117:2301-2307.
  • Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and me- ta-analysis approach. Surv Ophthalmol 2000;44:367-408.
  • Kubaloğlu A, Sari ES, Cinar Y, et al. Intrastromal corneal ring segment implantation for the treatment of keratoconus. Cornea 2011;30:11-17.
  • Cinar Y, Cingu AK, Sahin A, et al. Intraoperative corneal thickness measurements during corneal collagen cross-link- ing with isotonic riboflavin solution without dextran in cor- neal ectasia. Cutan Ocul Toxicol 2013. Basım aşamasında, DOI: 10.3109/15569527.2013.793700
  • Khoramnia R, Rabsilber TM, Auffarth GU. Central and pe- ripheral pachymetry measurements according to age using the Pentacam rotating Scheimpflug camera. J Cataract Re- fract Surg 2007;33:830-836.
  • Rufer F, Schroder A, Bader C, Erb C. Age-related changes in central and peripheral corneal thickness: determination of normal values with the Orbscan II topography system. Cornea 2007;26:1-5.
  • Çinal A, Topuz H, Şimşek Ş, Demirok A. Age and corneal topography. MN Oftalmoloji Dergisi 2002;9:230-233.
  • Emre S, Doğanay S, Yoloğlu S. Sağlıklı Bireylerde Pentacam ile Elde Edilen Ön Segment Parametreleri Üzerine Yaşın Etkisinin Degerlendirilmesi. T Oft Gaz 2008;38:452-458.
  • Jonsson M, Markstrom K, Behndig A. Slit-scan tomog- raphy evaluation of the anterior chamber and corneal configurations at different ages. Acta Ophthalmol Scand 2006;84:116-120.
  • Ambrosio R, Alonso RS, Luz A, Coca Velarde LG. Corneal- thickness spatial profile and corneal-volume distribution: tomographic indices to detect keratoconus. J Cataract Re- fract Surg 2006;32:1851-1859.
  • Rabsilber TM, Khoramnia R, Auffarth GU. Anterior cham- ber measurements using Pentacam rotating Scheimpflug camera. J Cataract Refract Surg 2006;32:456-459.
  • Randleman JB, Woodward M, Lynn MJ, Stulting RD. Risk assessment for ectasia after corneal refractive surgery. Oph- thalmology 2008;115:37-50.
  • Muallem MS, Yoo SH, Romano AC, et al. Flap and stromal bed thickness in laser in situ keratomileusis enhancement. J Cataract Refract Surg 2004;30:2295-302.
  • Sari ES, Pinero DP, Kubaloğlu A, et al. Toric implantable collamer lens for moderate to high myopic astigmatism: 3-year follow-up. Graefes Arch Clin Exp Ophthalmol 2013;251:1413-1422.
  • Olsen T, Corydon L, Gimbel H. Intraocular lens power cal- culation with an improved anterior chamber depth predic- tion algorithm. J Cataract Refract Surg 1995;21:313-319.
  • Lowe RF. Anterior lens displacement with age. Br J Oph- thalmol 1970;54:117-121.
  • Özer A, Şorabatur M, Şahin A, ve ark. Ön Kamara Derin- liginin Korneal Topografi ve Keratometre Yöntemleri ile Degerlendirilmesi. Glokom-Katarakt 2006;1:93-96.
Toplam 18 adet kaynakça vardır.

Ayrıntılar

Birincil Dil Türkçe
Bölüm Araştırma Yazıları
Yazarlar

Yasin Çınar Bu kişi benim

Abdullah Kürşat Cingü Bu kişi benim

Tuba Çınar Bu kişi benim

Fatih Mehmet Türkcü Bu kişi benim

Harun Yüksel Bu kişi benim

İhsan Çaça Bu kişi benim

Yayımlanma Tarihi 1 Aralık 2013
Gönderilme Tarihi 2 Mart 2015
Yayımlandığı Sayı Yıl 2013

Kaynak Göster

APA Çınar, Y., Cingü, A. K., Çınar, T., Türkcü, F. M., vd. (2013). Emetropik gözlerde pentacam ile ön segment parametrelerinin yaş gruplarına göre karşılaştırılması. Dicle Tıp Dergisi, 40(4), 627-631. https://doi.org/10.5798/diclemedj.0921.2013.04.0345
AMA Çınar Y, Cingü AK, Çınar T, Türkcü FM, Yüksel H, Çaça İ. Emetropik gözlerde pentacam ile ön segment parametrelerinin yaş gruplarına göre karşılaştırılması. diclemedj. Aralık 2013;40(4):627-631. doi:10.5798/diclemedj.0921.2013.04.0345
Chicago Çınar, Yasin, Abdullah Kürşat Cingü, Tuba Çınar, Fatih Mehmet Türkcü, Harun Yüksel, ve İhsan Çaça. “Emetropik gözlerde Pentacam Ile ön Segment Parametrelerinin Yaş gruplarına göre karşılaştırılması”. Dicle Tıp Dergisi 40, sy. 4 (Aralık 2013): 627-31. https://doi.org/10.5798/diclemedj.0921.2013.04.0345.
EndNote Çınar Y, Cingü AK, Çınar T, Türkcü FM, Yüksel H, Çaça İ (01 Aralık 2013) Emetropik gözlerde pentacam ile ön segment parametrelerinin yaş gruplarına göre karşılaştırılması. Dicle Tıp Dergisi 40 4 627–631.
IEEE Y. Çınar, A. K. Cingü, T. Çınar, F. M. Türkcü, H. Yüksel, ve İ. Çaça, “Emetropik gözlerde pentacam ile ön segment parametrelerinin yaş gruplarına göre karşılaştırılması”, diclemedj, c. 40, sy. 4, ss. 627–631, 2013, doi: 10.5798/diclemedj.0921.2013.04.0345.
ISNAD Çınar, Yasin vd. “Emetropik gözlerde Pentacam Ile ön Segment Parametrelerinin Yaş gruplarına göre karşılaştırılması”. Dicle Tıp Dergisi 40/4 (Aralık 2013), 627-631. https://doi.org/10.5798/diclemedj.0921.2013.04.0345.
JAMA Çınar Y, Cingü AK, Çınar T, Türkcü FM, Yüksel H, Çaça İ. Emetropik gözlerde pentacam ile ön segment parametrelerinin yaş gruplarına göre karşılaştırılması. diclemedj. 2013;40:627–631.
MLA Çınar, Yasin vd. “Emetropik gözlerde Pentacam Ile ön Segment Parametrelerinin Yaş gruplarına göre karşılaştırılması”. Dicle Tıp Dergisi, c. 40, sy. 4, 2013, ss. 627-31, doi:10.5798/diclemedj.0921.2013.04.0345.
Vancouver Çınar Y, Cingü AK, Çınar T, Türkcü FM, Yüksel H, Çaça İ. Emetropik gözlerde pentacam ile ön segment parametrelerinin yaş gruplarına göre karşılaştırılması. diclemedj. 2013;40(4):627-31.