Amaç: Üç farklı yapıdaki CAD/CAM materyallerle bu materyallerin tamirinde kullanılan akışkan/tepilebilir kompozit rezinler arasında oluşan bağlantı dayanımının değerlendirilmesidir.
Yöntem: IPS e.max CAD (Ivoclar), Cerasmart (GC), Vita Enamic (Vita Zahnfabric) CAD/CAM materyallerden (7×7×2 mm) hazırlanan örnekler, otopolimerizan akrilikle sabitlendi (n=10). Örneklerin üst yüzeyleri 600-1200 SIC zımparayla 60 sn zımparalandı. Örnek yüzeyleri yeşil kuşaklı elmas frezle 10 sn pürüzlendirildi. Hazırlanan CAD/CAM yüzeylere G-Aenial Posterior (GC) veya G-Aenial Universal Flo (GC) 2-mm yüksekliğinde üretici firma önerileri doğrultusunda uygulandı. Tüm CAD/CAM yüzeylerde silan olarak G-Multi Primer; bonding ajan olarak G-2 Bond Universal kullanıldı. Tüm CAD/CAM yüzeylerinde kompozitler bir teflon kalıp kullanılarak tepildi ve polimerize edildi. Örneklere bağlanma dayanım testi (Shear Bond Test) uygulandı. Örnek yüzeyleri stereomikroskop altında incelenilerek kırılma tipleri belirlendi. Başarısızlık tipleri adeziv/CAD/CAM koheziv/kompozit koheziv/miks olarak sınıflandırıldı. Veriler tek yönlü varyans analizi (ANOVA) ve Tukey HSD testi kullanılarak analiz edildi (P < .05). Kırılma tipleri Ki-kare testi kullanılarak değerlendirildi.
Bulgular: CAD/CAM materyaller arası kıyaslamada, Vita Enamic ve Cerasmart yüzeylerinde benzer bağlanma dayanım değerleri elde edildi, IPS e.max CAD’de ise diğer CAD/CAM materyallereden daha düşük bağlanma dayanım değerleri elde edildi. G-Aenial Posterior veya G-Aenial Universal Flo’nun CAD/CAM yüzeylere bağlanması arasında benzer değerler tespit edildi. Kırılma tipi değerlendirilmesinde, IPS e.max CAD materyalinde adeziv tipte kırılma, Vita Enamic ve Cerasmart materyalinde ise CAD/CAM koheziv tipte kırılmalar görüldü.
Sonuç: Tamirde kullanılan kompozit rezinlerin, rezin bazlı CAD/CAM materyallere bağlanması seramik yapıdaki CAD/CAM materyaline bağlanmadan daha iyidir. Her iki kompozit rezinde tamir prosedüründe kullanılabilir.
Objective: The aim of this study is to evaluate the bond strength between CAD/CAM materials in three different structures and the flowable or paste composite resins used in their repair.
Method: Samples prepared IPS e.max CAD (Ivoclar)/Cerasmart (GC)/Vita Enamic (Vita Zahnfabric) CAD/CAM materials (7×7×2 mm) were fixed with autopolymerizing acrylic. A total of 60 samples were prepared (n=10). The surfaces of the samples were sanded with 600-1200 SIC sandpaper for 60 seconds. The sample surfaces were roughened with a green belted diamond bur for 10 seconds. The samples were first divided into 3 groups as IPS e.max CAD/Vita Enamic/Cerasmart. Each separated group was divided into 2 subgroups as G-Aenial Posterior (GC)/G-Aenial Universal Flo (GC) according to the type of resin. A silane G-Multi Primer (GC) and a bonding G-2 Bond Universal (GC) were applied to all sample surfaces at the manufacturer's recommendation. The repair process was completed with a packable/flowable composite using a mold on the sample surfaces. Bond strength test was performed on the samples. Fracture types were determined by looking at the sample surfaces under a stereomicroscope. Failure types were classified and recorded as adhesive/CAD/CAM cohesive/composite cohesive/mixed. Data were analyzed with one way Analysis of Variance (ANOVA) and Tukey HSD tests (P < .05). Fracture types were evaluated using the Chi-square test.
Result: In comparison between CAD/CAM materials; Vita Enamic/Cerasmart had similar MPa values, but lower MPa values for IPS e.max CAD than other CAD/CAM materials. Similar binding values were determined between G-Aenial Posterior/G-Aenial Universal Flo used in the repair of Cerasmart/IPS e.max CAD/Vita Enamic materials. In the evaluation of the fracture type; Adhesive type breakage was observed in IPS e.max CAD material, CAD/CAM cohesive type breakage was observed in Vita Enamic/Cerasmart material.
Conclusions: The bonding of composite resins used for repair to resin-based CAD/CAM materials is better than bonding to ceramic CAD/CAM materials. The use of a touchable composite or flowable composite is similar in repairing resin-based CAD/CAM materials.
Birincil Dil | Türkçe |
---|---|
Konular | Diş Hekimliği |
Bölüm | Araştırma Makaleleri |
Yazarlar | |
Yayımlanma Tarihi | 28 Ağustos 2024 |
Kabul Tarihi | 15 Nisan 2024 |
Yayımlandığı Sayı | Yıl 2024 |
Dergimize sadece Araştırma makalesi, vaka raporu ve Derleme türündeki yayınlarınızı dergimize gönderebilirsiniz. Dergimiz, Uluslararası ve ulusal indekslerce taranmaktadır.
Uluslararası Diş Hekimliği Bilimleri Dergisi Europub, Asian Science Citation Index, Asos index, ACAR index ve Google Scholar tarafından dizinlenmektedir. Ayrıca, TR Dizin ve diğer indekslere başvuru yapılmıştır.