Araştırma Makalesi

Evaluation of Stain Susceptibility of Different CAD/CAM Blocks After Immersion in Coffee

Cilt: 11 Sayı: 3 20 Eylül 2021
PDF İndir
TR EN

Evaluation of Stain Susceptibility of Different CAD/CAM Blocks After Immersion in Coffee

Öz

Aim: Color stability is gaining more importance today due to majority of patients are seeking color matching restorations. However, there is still lack of information on staining and changes in translucency of recent CAD/CAM block materials. The goal of the current study was to evaluate the discoloration susceptibility, translucency change, water solubility, and water sorption of different CAD/CAM materials after one-month of immersion in coffee. Material and Methods: Four CAD/CAM block materials and one conventional composite resin were examined. The CIELab values of CAD/CAM materials were determined using a clinical spectrophotometer on black and white backgrounds. The color changes and translucency differences were calculated after immersion in coffee or distilled water for one month (n=6). Water solubility and sorption were also determined according to the ISO 4049:2009 (n=6). The data were calculated by 2-way ANOVA and Tukey’s pair-wise comparisons (α=0.05). Results: Color changes of the CAD/CAM materials tested ranged from 1.5 to 7.3, and translucency reduced. The highest color change was observed in nanocomposite resin (7.3), whereas the lowest color change was observed in feldspathic porcelain (1.5) after storing in coffee for a month. There was no significant difference among the polymer-based CAD/CAM materials. No correlation was determined between color changes and water sorption/solubility. Conclusion: All materials except feldspar ceramic showed a discoloration exceeding the clinically acceptable threshold level (2.7) after being stored in coffee for one month. The highest color change was observed in nanocomposite resin material.

Anahtar Kelimeler

Kaynakça

  1. 1. Conrad HJ, Seong WJ, Pesun IJ. Current ceramic materials and systems with clinical recommendations: A systematic review. J Prosthet Dent. 2007; 98(5): 389-404.
  2. 2. della Bona A, Kelly JR. The clinical success of all-ceramic restorations. J Am Dent Assoc. 2008; 139(4): 8-13.
  3. 3. Samra APB, Pereira SK, Delgado LC, Borges CP. Color stability evaluation of aesthetic restorative materials. Braz Oral Res. 2020; 22(3): 205-210.
  4. 4. Fontes ST, Fernández MR, de Moura CM, Meireles SS. Color stability of a nanofill composite: effect of different immersion media. J Appl Oral Sci. 2020; 17(5): 388-391.
  5. 5. Watts A, Addy M. Tooth discolouration and staining: A review of the literature. Br Dent J. 2001; 190(6): 309-316.
  6. 6. Choi MS, Lee YK, Lim BS, Rhee SH, Yang HC. Changes in surface characteristics of dental resin composites after polishing. J Mater Sci. 2005; 16(4): 347-353.
  7. 7. Awad D, Stawarczyk B, Liebermann A, Ilie N. Translucency of esthetic dental restorative CAD/CAM materials and composite resins with respect to thickness and surface roughness. J Prosthet Dent. 2015; 113(6): 534-540.
  8. 8. Ardu S, Braut V, Gutemberg D, Krejci I, Dietschi D, Feilzer AJA. A long-term laboratory test on staining susceptibility of esthetic composite resin materials. Quintessence Int. 2010; 41(8): 695-702.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Sağlık Kurumları Yönetimi

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

20 Eylül 2021

Gönderilme Tarihi

14 Aralık 2020

Kabul Tarihi

16 Mayıs 2021

Yayımlandığı Sayı

Yıl 2021 Cilt: 11 Sayı: 3

Kaynak Göster

APA
Şişmanoğlu, S., & Gürcan, A. T. (2021). Evaluation of Stain Susceptibility of Different CAD/CAM Blocks After Immersion in Coffee. Düzce Üniversitesi Sağlık Bilimleri Enstitüsü Dergisi, 11(3), 284-289. https://doi.org/10.33631/duzcesbed.840660
AMA
1.Şişmanoğlu S, Gürcan AT. Evaluation of Stain Susceptibility of Different CAD/CAM Blocks After Immersion in Coffee. DÜ Sağlık Bil Enst Derg. 2021;11(3):284-289. doi:10.33631/duzcesbed.840660
Chicago
Şişmanoğlu, Soner, ve Aliye Tuğçe Gürcan. 2021. “Evaluation of Stain Susceptibility of Different CAD/CAM Blocks After Immersion in Coffee”. Düzce Üniversitesi Sağlık Bilimleri Enstitüsü Dergisi 11 (3): 284-89. https://doi.org/10.33631/duzcesbed.840660.
EndNote
Şişmanoğlu S, Gürcan AT (01 Eylül 2021) Evaluation of Stain Susceptibility of Different CAD/CAM Blocks After Immersion in Coffee. Düzce Üniversitesi Sağlık Bilimleri Enstitüsü Dergisi 11 3 284–289.
IEEE
[1]S. Şişmanoğlu ve A. T. Gürcan, “Evaluation of Stain Susceptibility of Different CAD/CAM Blocks After Immersion in Coffee”, DÜ Sağlık Bil Enst Derg, c. 11, sy 3, ss. 284–289, Eyl. 2021, doi: 10.33631/duzcesbed.840660.
ISNAD
Şişmanoğlu, Soner - Gürcan, Aliye Tuğçe. “Evaluation of Stain Susceptibility of Different CAD/CAM Blocks After Immersion in Coffee”. Düzce Üniversitesi Sağlık Bilimleri Enstitüsü Dergisi 11/3 (01 Eylül 2021): 284-289. https://doi.org/10.33631/duzcesbed.840660.
JAMA
1.Şişmanoğlu S, Gürcan AT. Evaluation of Stain Susceptibility of Different CAD/CAM Blocks After Immersion in Coffee. DÜ Sağlık Bil Enst Derg. 2021;11:284–289.
MLA
Şişmanoğlu, Soner, ve Aliye Tuğçe Gürcan. “Evaluation of Stain Susceptibility of Different CAD/CAM Blocks After Immersion in Coffee”. Düzce Üniversitesi Sağlık Bilimleri Enstitüsü Dergisi, c. 11, sy 3, Eylül 2021, ss. 284-9, doi:10.33631/duzcesbed.840660.
Vancouver
1.Soner Şişmanoğlu, Aliye Tuğçe Gürcan. Evaluation of Stain Susceptibility of Different CAD/CAM Blocks After Immersion in Coffee. DÜ Sağlık Bil Enst Derg. 01 Eylül 2021;11(3):284-9. doi:10.33631/duzcesbed.840660

Cited By