EN
A Rare Mechanical Cause of Extubation Failure After Short-Term Intubation and Outgoing with the Stridor Clinic: Obstructive Fibrinous Tracheal Pseudomembrane : A CASE REPORT
Öz
Stridor after extubation is generally a clinical symptom that may indicate laryngeal edema or vocal cord injury due to intubation, and hoarseness may accompany this.The presence of stridor may cause reintubation due to upper airway obstruction, a risk factor for patient mortality and morbidity.Laryngeal edema and vocal cord damage are mostly seen as the cause of stridor.In this case, OFTP (Obstructive fibrinous tracheal pseudomembrane) and stridor in the lower line of the vocal cords, which are rarely seen during short-term intubation, are presented.
Anahtar Kelimeler
Kaynakça
- 1.Frutos-Vivar, F., Esteban, A., Apezteguia, C., González, M., Arabi, Y., Restrepo, M. I., Gordo, F., Santos, C., Alhashemi, J. A., Pérez, F., Peñuelas, O., & Anzueto, A. (2011).Outcome of reintubated patients after scheduled extubation. Journal of critical care, 26(5), 502–509. https://doi.org/10.1016/j.jcrc.2010.12.015
- 2.Miltiades, A. N., Gershengorn, H. B., Hua, M., Kramer, A. A., Li, G., & Wunsch, H. (2017). Cumulative probability and time to reintubation in U.S. ICUs. Critical care medicine, 45(5), 835-842. https://doi.org/10.1097/CCM.0000000000002327
- 3.Pluijms, W.A., van Mook, W.N., Wittekamp, B.H. et al. Postextubation laryngeal edema and stridor resulting in respiratory failure in critically ill adult patients: updated review. Crit Care 19, 295 (2015). https://doi.org/10.1186/s13054-015-1018-2
- 4.Zochios, V., Protopapas, A. D., & Valchanov, K. (2015). Stridor in adult patients presenting from the community: An alarming clinical sign. Journal of the Intensive Care Society, 16(3), 272–273. https://doi.org/10.1177/1751143714568773
- 5.Lilienstein JT, Davis JW, Bilello JF, Dirks RC. risk factors associated with post -extubation stridor in the trauma intensive resort unit The American Journal of Surgery.2016;212:379 -83. https://doi.org/10.1016/j.amjsurg.2016.02.010.
- 6.Vallés, J., Millán, S., Díaz, E., Castanyer, E., Gallardo, X., Martín-Loeches, I., Andreu, M.,Prenafeta, M., Saludes, P., Lema, J., Batlle, M., Bacelar, N., & Artigas, A. (2017). Incidence of airway complications in patients using endotracheal tubes with continuous aspiration of subglottic secretions. Annals of intensive care, 7(1), 109. https://doi.org/10.1186/s13613-017- 0331-0
- 7.El-Baradey, G. F., El-Shmaa, N. S., & Elsharawy, F. (2016). Ultrasound-guided laryngeal air column width difference and the cuff leak volume in predicting the effectiveness of steroid therapy on postextubation stridor in adult. Are they useful?. Journal of critical care, 36, 272– 276. https://doi.org/10.1016/j.jcrc.2016.07.007
- 8.Jaber, S., Chanques, G., Matecki, S., Ramonatxo, M., Vergne, C., Souche, B., Perrigault, P. F., & Eledjam, J. J. (2003). Post-extubation stridor in intensive care unit patients. Risk factors evaluation and importance of the cuff-leak test. Intensive care medicine, 29(1), 69–74. https://doi.org/10.1007/s00134-002-1563-4
Ayrıntılar
Birincil Dil
İngilizce
Konular
Yoğun Bakım
Bölüm
Olgu Sunumu
Erken Görünüm Tarihi
6 Eylül 2023
Yayımlanma Tarihi
6 Eylül 2023
Gönderilme Tarihi
9 Haziran 2023
Kabul Tarihi
15 Ağustos 2023
Yayımlandığı Sayı
Yıl 2023 Cilt: 5 Sayı: 2
APA
Gökmen, N., & Ernur, D. (2023). A Rare Mechanical Cause of Extubation Failure After Short-Term Intubation and Outgoing with the Stridor Clinic: Obstructive Fibrinous Tracheal Pseudomembrane : A CASE REPORT. Eurasian Journal of Critical Care, 5(2), 70-73. https://doi.org/10.55994/ejcc.1312037
AMA
1.Gökmen N, Ernur D. A Rare Mechanical Cause of Extubation Failure After Short-Term Intubation and Outgoing with the Stridor Clinic: Obstructive Fibrinous Tracheal Pseudomembrane : A CASE REPORT. Eurasian Journal of Critical Care. 2023;5(2):70-73. doi:10.55994/ejcc.1312037
Chicago
Gökmen, Necati, ve Damla Ernur. 2023. “A Rare Mechanical Cause of Extubation Failure After Short-Term Intubation and Outgoing with the Stridor Clinic: Obstructive Fibrinous Tracheal Pseudomembrane : A CASE REPORT”. Eurasian Journal of Critical Care 5 (2): 70-73. https://doi.org/10.55994/ejcc.1312037.
EndNote
Gökmen N, Ernur D (01 Eylül 2023) A Rare Mechanical Cause of Extubation Failure After Short-Term Intubation and Outgoing with the Stridor Clinic: Obstructive Fibrinous Tracheal Pseudomembrane : A CASE REPORT. Eurasian Journal of Critical Care 5 2 70–73.
IEEE
[1]N. Gökmen ve D. Ernur, “A Rare Mechanical Cause of Extubation Failure After Short-Term Intubation and Outgoing with the Stridor Clinic: Obstructive Fibrinous Tracheal Pseudomembrane : A CASE REPORT”, Eurasian Journal of Critical Care, c. 5, sy 2, ss. 70–73, Eyl. 2023, doi: 10.55994/ejcc.1312037.
ISNAD
Gökmen, Necati - Ernur, Damla. “A Rare Mechanical Cause of Extubation Failure After Short-Term Intubation and Outgoing with the Stridor Clinic: Obstructive Fibrinous Tracheal Pseudomembrane : A CASE REPORT”. Eurasian Journal of Critical Care 5/2 (01 Eylül 2023): 70-73. https://doi.org/10.55994/ejcc.1312037.
JAMA
1.Gökmen N, Ernur D. A Rare Mechanical Cause of Extubation Failure After Short-Term Intubation and Outgoing with the Stridor Clinic: Obstructive Fibrinous Tracheal Pseudomembrane : A CASE REPORT. Eurasian Journal of Critical Care. 2023;5:70–73.
MLA
Gökmen, Necati, ve Damla Ernur. “A Rare Mechanical Cause of Extubation Failure After Short-Term Intubation and Outgoing with the Stridor Clinic: Obstructive Fibrinous Tracheal Pseudomembrane : A CASE REPORT”. Eurasian Journal of Critical Care, c. 5, sy 2, Eylül 2023, ss. 70-73, doi:10.55994/ejcc.1312037.
Vancouver
1.Necati Gökmen, Damla Ernur. A Rare Mechanical Cause of Extubation Failure After Short-Term Intubation and Outgoing with the Stridor Clinic: Obstructive Fibrinous Tracheal Pseudomembrane : A CASE REPORT. Eurasian Journal of Critical Care. 01 Eylül 2023;5(2):70-3. doi:10.55994/ejcc.1312037