The Effect of LED Deployment on RSSI-based VLP Systems
Abstract
In this paper, the effect of light emitting diode (LED) deployment is investigated based on the received signal strength indication (RSSI) technique for visible light positioning (VLP) systems. The optical code division multiple access (OCDMA) is used as a multiplexing technique to transmit the location and RSSI information of LEDs simultaneously. For different highly reflective indoor scenarios, LEDs are placed on the ceiling of a room considering homogeneous illumination. The illuminance of the room is provided particularly with 400 lux minimally at the desk height. In order to demonstrate the uniformity of lighting for different indoor scenarios, the uniformity illuminance ratio (UIR) values are also obtained in this study. In addition, electrical signal-to-noise ratio (SNR), an important parameter for reliable communication, is calculated at desk height for each scenario considered and an SNR level of 45 dB is obtained at a minimum. The simulation results demonstrate that the mean square error (MSE) of the estimated location is reduced with an increase in the number of visible access points (VAPs). The MSE of the distance for number of VAPs 12 and 16 are the best, however, the scenario with 16 VAPs is preferable with a better uniformity illuminance ratio (UIR) parameter. In terms of illuminance, all the cases have the average illuminance value more than 450 lux.
Keywords
Destekleyen Kurum
Proje Numarası
Teşekkür
Kaynakça
- Do, T.-H. and Yoo, M. 2016. An in-depth survey of visible light communication based positioning systems, Sensors, 16, 5, pp. 1–40. https://doi.org/10.3390/s16050678
- Khan, L.U. 2017. Visible light communication: Applications, architecture, standardization and research challenges, Digital Communications and Networks, 3, 2, pp. 78–88. https://doi.org/10.1016/j.dcan.2016.07.004
- Tanaka, T. and Haruyama, S. 2009. New position detection method using image sensor and visible light LEDs, in Proc. IEEE 2nd Int. Conf., pp. 150–153, Dubai, United Arab Emirates. https://doi.org/10.1109/ICMV.2009.44
- Hann, S., Kim, J.-H., Jung, S.-Y., and Park, C.-S. 2010. White led ceiling lights positioning systems for optical wireless indoor applications, in Proc. 36th Eur. Conf. Exhib. Opt. Commun., pp. 1–3, Torino, Italy. https://doi.org/10.1109/ECOC.2010.5621490
- Lou, P., Zhang, H., Zhang, X., Yao, M. and Xu, Z. 2012. Fundamental analysis for indoor visible light positioning system, in Proc. 1st IEEE Int. Conf. Commun. China Workshops, pp. 59–63, Bejing, China. https://doi.org/10.1109/ICCCW.2012.6316475
- Lee, Y. U. and Kavehrad, M. 2012. Two hybrid positioning system design techniques with lighting LEDs and ad-hoc wireless network, IEEE Trans. Consumer Electron., 58, 4, pp. 1176–1184. https://doi.org/10.1109/TCE.2012.6414983
- Yasir, M., Ho, S.-W., and Vellambi, B. 2014. Indoor positioning system using visible light and accelerometer, J. Lightw. Technol., 32, 19, pp. 3306–3316. https://doi.org/10.1109/JLT.2014.2344772
- Hassan, N. U., Naeem, A., Pasha, M. A., Jadoon, T., and Yuen, C. 2015. Indoor positioning using visible LED lights: A survey,'' ACM Comput. Surveys, 48, 2, pp. 1–32. https://doi.org/10.1145/2835376
Ayrıntılar
Birincil Dil
İngilizce
Konular
Mühendislik
Bölüm
Araştırma Makalesi
Yazarlar
Yasin Çelik
*
0000-0001-8972-9970
Türkiye
Yayımlanma Tarihi
31 Aralık 2019
Gönderilme Tarihi
3 Ekim 2019
Kabul Tarihi
1 Aralık 2019
Yayımlandığı Sayı
Yıl 2019 Sayı: 17