Araştırma Makalesi

An Assessment of Radiation Protection and Shielding Properties of 256 Slice Computed Tomography (CT) Facility: Intermed Nisantasi

Sayı: 17 31 Aralık 2019
PDF İndir
TR EN

An Assessment of Radiation Protection and Shielding Properties of 256 Slice Computed Tomography (CT) Facility: Intermed Nisantasi

Abstract

Kaynakça

  1. Wall, B. F., Hart, D., (1997). Revised radiation doses for typical x-ray examinations. The British Journal of Radiology, 70: 437-439.
  2. Neeman, Z., et.al., (2006). CT Fluoroscopy Shielding Decreases in Scattered Radiation for the Patiendt and Operator. J Vasc Interv Radiol, 2006 Dec; 17(12):. (1999–2004).
  3. Stoeckelhuber, B. M., Leibecke, T., Schulz, E., et al., (2005). Radiation dose to the radiologist’s hand during continuous CT fluoroscopy-guided interventions. Cardiovasc Intervent Radiol, 28:589–594
  4. Richard, D., et.al., (2000). Patient and Personnel Exposure during CT Fluoroscopy-guided Interventional Procedures. RSNA Radiology V. 216 (1).
  5. Every, V., Petty, R. J., (1992). Measurements of computed tomography radiation scatter. Australas Phys.Eng. Sci. Med., 15(1) pp.15-24.
  6. Stoeckelhuber, B. M., Leibecke, T., Schulz, E., et al. (2005). Radiation dose to the radiologist’s hand during continuous CT fluoroscopy-guided interventions. Cardiovasc Intervent Radiol. 28: pp. 589–594.
  7. Salvado, M., et.al., (2005). Monte Carlo calculation of radiation dose in CT examinations using phantom and patient tomographic models. Radiation Protection Dosimetry. 114(1-3):364-8.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Mühendislik

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

31 Aralık 2019

Gönderilme Tarihi

1 Kasım 2019

Kabul Tarihi

21 Kasım 2019

Yayımlandığı Sayı

Yıl 2019 Sayı: 17

Kaynak Göster

APA
Cavlı, B. (2019). An Assessment of Radiation Protection and Shielding Properties of 256 Slice Computed Tomography (CT) Facility: Intermed Nisantasi. Avrupa Bilim ve Teknoloji Dergisi, 17, 803-806. https://doi.org/10.31590/ejosat.645101