Araştırma Makalesi

QCM-based biosensor for the Detection of Homocysteine

Sayı: 20 31 Aralık 2020
PDF İndir
TR EN

QCM-based biosensor for the Detection of Homocysteine

Öz

High plasma homocysteine levels can cause an increased risk of cardiovascular, cerebrovascular, and peripheral arterial diseases. Besides this, Alzheimer’s disease and other dementias, osteoporosis, diabetes and renal disease due to folate and B-vitamin deficiency, various drugs or pre-existing atherosclerotic diseases may be the result of high homocysteine levels. The presented research work aimedto perform the detection of Homocysteine (Hcy) by using Quartz Crystal Microbalance (QCM) biosensor. The temperature controlled QCM system was a home-made designed and constructed equipment which can use silver electrod quartz crystal. The modification of silver electrod quartz crystals surfaces was achieved by the surface cleaning process with sodium hydroxide, acetone and methanol in a consecutive manner. Then self-assembled monolayer of cysteamine and chemical coupling of glutaraldehyde (GA) to free end of monolayer was achieved to create the new functional surface in order to complete the formation of spacer arm/ligand. Homocysteine specific recognizing ligand, anti-Homocysteine antibody was immobilized to glutaraldehyde coupled surfaces. The change in resonance frequency values were measured for each modification step. The optimization of dilution ratio of the antibody solution was performed to modified surfaces. The least dilution ratio of antibody, 1/10000 v/v, was determined as optimum antibody ratio. The detection of homocystein was analysed at a detection limit of 0.1 µM and the linear ranges of calibration curves were estimated as 0.1-2.0 µM and 10-50 µM. Homocysteine values indicated good linearities (R2=0.9813 and 0.9875, respectively). The relative standart deviation (RSD %) for precision was calculated as less than 10%. In conclusion, it was found that the detection of homocysteine can be done both in nano- and micro-molar concentration levels. Additionally, designed biosensor showed desired stability and reproducibility. Finally, a new method different from the present methods for the use in the analysis of Hcy was proposed and developed which detects homocysteine by designed QCM technique with a rapid, cheeper and less pretreatment processes. Additionally, homocysteine detection was performed in nano- and micro- molar concentration values.

Anahtar Kelimeler

Destekleyen Kurum

THE SCIENTIFIC AND TECHNOLOGICAL RESEARCH COUNCIL OF TURKEY

Proje Numarası

105S052

Teşekkür

Special thanks to Prof. Dr. Hakan Ayhan and Prof. Dr. İ. Cengiz Koçum for their scientific support.

Kaynakça

  1. Abraham, JM, Cho, L, (2010) The homocysteine hypothesis: Still relevant to the prevention and treatment of cardiovascular disease? (Review). Cleveland Clinic Journal Of Medicine, 77:911-18.
  2. Alam, S. F., Kumar, S., Ganguly, P., (2019). Measurement of homocysteine: a historical Perspective. J. Clin. Biochem. Nutr. November, 65, 3, 171–177.
  3. Andersson, M, Andersson, J, Sellborn, A. Berglin, M., Nilsson, B., Elwing, H, (2005). Quartz crystal microbalance-with dissipation monitoring (QCM-D) for real time measurements of blood coagulation density and immune complement activation on artificial surfaces. Biosensors and Bioelectronics, 21: 79-86. Nutrition, 85:329–30.
  4. Ayhan, F, Gülsu, A, Ayhan, H, (2007) Quartz Crystal Piezo Electrode Surface Modification for Gold Nano-particles Immobilization. Hacettepe J. Biol. & Chem., 35: 203-208.
  5. Ayhan, F., Kaya, G., Ayhan, H. (2014). Homocysteine-BSA-affinity based biosensor design. Turkish Journal of Biochemistry, 9(3):383–396.
  6. Bakhshpour, M., Kevser Piskin, A., Yavuz, H., Denizli, A., (2019). Quartz crystal microbalance biosensor for label-free MDA MB 231 cancer cell detection via notch-4 receptor. Talanta, 204 840–845.
  7. Beitollahi, H., Zaimbashi, R., Mahani, M. T., Tajik, S., (2020). A label-free aptasensor for highly sensitive detection of homocysteine based on gold nanoparticles. Bioelectrochemistry 134, 107497.
  8. Bunde, RL, Jarvi, .J, Rosentreter, JJ, (1998) Piezo electric quartz crystal biosensor, Talanta, 46: 1223-36.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Mühendislik

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

31 Aralık 2020

Gönderilme Tarihi

13 Ağustos 2020

Kabul Tarihi

16 Aralık 2020

Yayımlandığı Sayı

Yıl 2020 Sayı: 20

Kaynak Göster

APA
Ayhan, F. (2020). QCM-based biosensor for the Detection of Homocysteine. Avrupa Bilim ve Teknoloji Dergisi, 20, 835-843. https://doi.org/10.31590/ejosat.777852
AMA
1.Ayhan F. QCM-based biosensor for the Detection of Homocysteine. EJOSAT. 2020;(20):835-843. doi:10.31590/ejosat.777852
Chicago
Ayhan, Fatma. 2020. “QCM-based biosensor for the Detection of Homocysteine”. Avrupa Bilim ve Teknoloji Dergisi, sy 20: 835-43. https://doi.org/10.31590/ejosat.777852.
EndNote
Ayhan F (01 Aralık 2020) QCM-based biosensor for the Detection of Homocysteine. Avrupa Bilim ve Teknoloji Dergisi 20 835–843.
IEEE
[1]F. Ayhan, “QCM-based biosensor for the Detection of Homocysteine”, EJOSAT, sy 20, ss. 835–843, Ara. 2020, doi: 10.31590/ejosat.777852.
ISNAD
Ayhan, Fatma. “QCM-based biosensor for the Detection of Homocysteine”. Avrupa Bilim ve Teknoloji Dergisi. 20 (01 Aralık 2020): 835-843. https://doi.org/10.31590/ejosat.777852.
JAMA
1.Ayhan F. QCM-based biosensor for the Detection of Homocysteine. EJOSAT. 2020;:835–843.
MLA
Ayhan, Fatma. “QCM-based biosensor for the Detection of Homocysteine”. Avrupa Bilim ve Teknoloji Dergisi, sy 20, Aralık 2020, ss. 835-43, doi:10.31590/ejosat.777852.
Vancouver