Araştırma Makalesi

Independent Joint Control Simulations on Adaptive Maneuvering of a Magnetotactic Bacterium via a Single Permanent Magnet

30 Kasım 2020
PDF İndir
TR EN

Independent Joint Control Simulations on Adaptive Maneuvering of a Magnetotactic Bacterium via a Single Permanent Magnet

Öz

The use of micro-robotic systems in non-invasive medicine has been heavily promoted in the literature for the last decade. The studies usually focus on artificial or biohybrid microswimmers of various origins subject to the effect of an external electromagnetic field controlled by a computer. Although there exist several motion control studies shared to date, control of a bio-hybrid microswimmer has rarely been demonstrated employing an open kinematic chain, in detail. In this work, motion control of an isolated magnetotactic bacterium cell (Magnetospirillum Gryphiswaldens) is presented via a magnetic field actively positioned by an open kinematic chain. The cell is modeled with its complete environment to make it as realistic as possible along with the magnetic torque, which is induced by a single magnet attached at the end effector of a robotic arm, exerted on it for maneuvering control. The control is based on a proportional – integral – derivative (PID) gain scheme with adaptive integral gain to focus on a particular steady-state error with discontinuous reference signals. The control signal is transformed into pulse width modulation (PWM) signals to drive the motors articulating the joints of the open kinematic chain, the inverse kinematics of which is designed to be simple enough to achieve independent joint control. A numerical analysis of the coupled system is carried out in the time domain. The performance of the said motion control approach is investigated for each degree of freedom for the planar motion of the microswimmer. Simulations demonstrate a planar open kinematic chain is capable of control the gait of the microswimmer while following its trajectory near a planar boundary via independent joint control. Furthermore, simulations demonstrate that the effective magnetic inertia and the shear stress results in a small but certain lag in the motion control performance of the overall system.

Anahtar Kelimeler

Kaynakça

  1. François, Q., André, A., Duplat, B., Haliyo, S., & Régnier, S. (2019) Tracking systems for intracranial medical devices: a review, Medical Devices and Sensors, 2(2), e10033. https://doi.org/10.1002/mds3.10033
  2. Ceylan, H., Giltinan, J., Kozielski, K., & Sitti, M. (2017) Mobile microrobots for bioengineering applications, Lab on a Chip, 17(10), 1705-1724. https://doi.org/10.1039/C7LC00064B
  3. Sitti, M., Ceylan, H., Hu, W., Giltinan, J., Turan, M., Yim, S., & Diller, E. (2015) Biomedical applications of untethered mobile milli/microrobots, Proceedings of the IEEE, 103(2), 205-224. https://doi.org/10.1109/JPROC.2014.2385105
  4. Nelson, B.J., Kaliakatsos, I.K., & Abbott, J.J. (2010) Microrobots for minimally invasive medicine, Annual Review of Biomedical Engineering, 12, 55-85. https://doi.org/10.1146/annurev-bioeng-010510-103409
  5. Tabak, A.F. (2019) Bioinspired and biomimetic micro-robotics for therapeutic applications, in Handbook of Biomechatronics, 1. Ed., J. Segil, Eds., Academic Press, U.K. https://doi.org/10.1016/b978-0-12-812539-7.00010-6
  6. Singh, A.V., Ansari, M.H.D., Laux, P., & Luch, A., (2019) Micronanorobots: important considerations when developing novel drug delivery platforms, Expert Opinion on Drug Delivery, 16(11), 1259-1275. https://doi.org/10.1080/17425247.2019.1676228
  7. Soto, F., & Chrostowski, R. (2018) Frontiers of medical micro/nanorobotics: in vivo applications and commercialization perspectives toward clinical uses, Frontiers in Bioengineering and Biotechnology, 6, 170. https://doi.org/10.3389/fbioe.2018.00170
  8. Dreyfus, R., Baudry, J., Roper, M.L., Fermigier, M., Stone, H.A., & Bibette, J. (2005) Microscopic artificial swimmers, Nature, 437, 862-865. https://doi.org/10.1038/nature04090

Ayrıntılar

Birincil Dil

İngilizce

Konular

Mühendislik

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

30 Kasım 2020

Gönderilme Tarihi

31 Ekim 2020

Kabul Tarihi

6 Kasım 2020

Yayımlandığı Sayı

Yıl 2020

Kaynak Göster

APA
Tabak, A. F. (2020). Independent Joint Control Simulations on Adaptive Maneuvering of a Magnetotactic Bacterium via a Single Permanent Magnet. Avrupa Bilim ve Teknoloji Dergisi, 50-59. https://doi.org/10.31590/ejosat.818986
AMA
1.Tabak AF. Independent Joint Control Simulations on Adaptive Maneuvering of a Magnetotactic Bacterium via a Single Permanent Magnet. EJOSAT. Published online 01 Kasım 2020:50-59. doi:10.31590/ejosat.818986
Chicago
Tabak, Ahmet Fatih. 2020. “Independent Joint Control Simulations on Adaptive Maneuvering of a Magnetotactic Bacterium via a Single Permanent Magnet”. Avrupa Bilim ve Teknoloji Dergisi, Kasım 1, 50-59. https://doi.org/10.31590/ejosat.818986.
EndNote
Tabak AF (01 Kasım 2020) Independent Joint Control Simulations on Adaptive Maneuvering of a Magnetotactic Bacterium via a Single Permanent Magnet. Avrupa Bilim ve Teknoloji Dergisi 50–59.
IEEE
[1]A. F. Tabak, “Independent Joint Control Simulations on Adaptive Maneuvering of a Magnetotactic Bacterium via a Single Permanent Magnet”, EJOSAT, ss. 50–59, Kas. 2020, doi: 10.31590/ejosat.818986.
ISNAD
Tabak, Ahmet Fatih. “Independent Joint Control Simulations on Adaptive Maneuvering of a Magnetotactic Bacterium via a Single Permanent Magnet”. Avrupa Bilim ve Teknoloji Dergisi. 01 Kasım 2020. 50-59. https://doi.org/10.31590/ejosat.818986.
JAMA
1.Tabak AF. Independent Joint Control Simulations on Adaptive Maneuvering of a Magnetotactic Bacterium via a Single Permanent Magnet. EJOSAT. 2020;:50–59.
MLA
Tabak, Ahmet Fatih. “Independent Joint Control Simulations on Adaptive Maneuvering of a Magnetotactic Bacterium via a Single Permanent Magnet”. Avrupa Bilim ve Teknoloji Dergisi, Kasım 2020, ss. 50-59, doi:10.31590/ejosat.818986.
Vancouver
1.Ahmet Fatih Tabak. Independent Joint Control Simulations on Adaptive Maneuvering of a Magnetotactic Bacterium via a Single Permanent Magnet. EJOSAT. 01 Kasım 2020;50-9. doi:10.31590/ejosat.818986

Cited By