Potentiometric Perchlorate - Selective PVC - Membrane Sensor Based on Methyltrioctylammonium Chloride

Yıl 2017, Cilt: 33 Sayı: 1, 1 - 9, 17.04.2017

Öz

In this study; a potentiometric PVC membrane ion
-
selective electrode
(ISE)
for
the
determination
of
perchlorate
was
developed.
Methyltrioctylammonium chloride,
a
lipophilic quaternary
ammonium salt, were
used as ionophore substance in electrode membrane
structures. The electrode
membrane was composed of at the ratio of 3% izoniazid
-
tetraphenylborate ion
pair, 67% nitrophenyloctylether and 30% PVC. For this electrode, linear range,
slope, detection limit, pH working range and response time were determined
as
1.0×10
-
6
-
1.0×10
-
1
M,
-
49.0 mV/decade, 9.0×10
-
7
M, 5.0
-
11.0 and ≈ 20 s,
respectively. The proposed electrode performed highly reproducible responses. It
was observed th
a
t the selectivity of the electrode was quite well when compared
to the some perchlor
ate selective electrodes available in literature. Analytical
application of the electrode was realized by determining the perchlorate contents
of the tap waters to which added certain amounts of perchlorate anions. The
obtained results by the electrode wer
e in good agrement with those of the added
perchlorate amounts.

Kaynakça

  • Referans1

Metiltrioktilamonyum Klorür Temelli Potansiyometrik Perklorat - Seçici PVC - Membran Sensör

Yıl 2017, Cilt: 33 Sayı: 1, 1 - 9, 17.04.2017

Öz

Bu çalışmada perklorat tayini için potansiyometrik bir PVC membran iyon
seçici elektrot (İSE) geliştirildi. Elektrot membranının yapısında iyonofor madde
olarak lipofilik bir
kuaterner
amonyum tuzu olan metiltrioktilamonyum klorür
kullanıldı. Elektrot mebr
anı % 3.0 metiltrioktilamonyum klorür, % 67.0
Nitrofeniloktileter, % 30.0 Polivinilklorür içermektedir. Elektrodun doğrusal
çalışma aralığı 1.0×10
-
6
-
1.0×10
-
1
M, 10 katlık konsantrasyon değişimindeki eğimi,
-
49.0 mV; tayin limiti, 9.0×10
-
7
M; pH çalışma ara
lığı, 5.0
-
11.0; cevap zamanı, ≈ 20 s
olarak belirlendi. Elektrot oldukça tekrarlanabilir bir potansiyometrik cevap
sergilemiştir. Elektrodun seçiciliği literatürde var olan bazı perklorat seçici
elektrotların seçicilikleriyle karşılaştırıldığında oldukça i
yi olduğu görüldü.
Elektrodun analitik uygulaması, içerisine belli miktarlarda perklorat iyonu
eklenmiş musluk sularında perklorat tayini yapılarak gerçekleştirildi. Elektrot
kullanılarak elde edilen sonuçların ilave edilen perklorat içerikleriyle oldukça
uyumlu olduğu gözlemlenmiştir.

Kaynakça

  • Referans1
Toplam 1 adet kaynakça vardır.

Ayrıntılar

Birincil Dil Türkçe
Konular Mühendislik
Bölüm Makaleler
Yazarlar

Fatih Çoldur Bu kişi benim

Müberra Andaç Bu kişi benim

Ahmet Önder Bu kişi benim

Yayımlanma Tarihi 17 Nisan 2017
Yayımlandığı Sayı Yıl 2017 Cilt: 33 Sayı: 1

Kaynak Göster

APA Çoldur, F., Andaç, M., & Önder, A. (2017). Metiltrioktilamonyum Klorür Temelli Potansiyometrik Perklorat - Seçici PVC - Membran Sensör. Erciyes Üniversitesi Fen Bilimleri Enstitüsü Fen Bilimleri Dergisi, 33(1), 1-9.
AMA Çoldur F, Andaç M, Önder A. Metiltrioktilamonyum Klorür Temelli Potansiyometrik Perklorat - Seçici PVC - Membran Sensör. Erciyes Üniversitesi Fen Bilimleri Enstitüsü Fen Bilimleri Dergisi. Nisan 2017;33(1):1-9.
Chicago Çoldur, Fatih, Müberra Andaç, ve Ahmet Önder. “Metiltrioktilamonyum Klorür Temelli Potansiyometrik Perklorat - Seçici PVC - Membran Sensör”. Erciyes Üniversitesi Fen Bilimleri Enstitüsü Fen Bilimleri Dergisi 33, sy. 1 (Nisan 2017): 1-9.
EndNote Çoldur F, Andaç M, Önder A (01 Nisan 2017) Metiltrioktilamonyum Klorür Temelli Potansiyometrik Perklorat - Seçici PVC - Membran Sensör. Erciyes Üniversitesi Fen Bilimleri Enstitüsü Fen Bilimleri Dergisi 33 1 1–9.
IEEE F. Çoldur, M. Andaç, ve A. Önder, “Metiltrioktilamonyum Klorür Temelli Potansiyometrik Perklorat - Seçici PVC - Membran Sensör”, Erciyes Üniversitesi Fen Bilimleri Enstitüsü Fen Bilimleri Dergisi, c. 33, sy. 1, ss. 1–9, 2017.
ISNAD Çoldur, Fatih vd. “Metiltrioktilamonyum Klorür Temelli Potansiyometrik Perklorat - Seçici PVC - Membran Sensör”. Erciyes Üniversitesi Fen Bilimleri Enstitüsü Fen Bilimleri Dergisi 33/1 (Nisan 2017), 1-9.
JAMA Çoldur F, Andaç M, Önder A. Metiltrioktilamonyum Klorür Temelli Potansiyometrik Perklorat - Seçici PVC - Membran Sensör. Erciyes Üniversitesi Fen Bilimleri Enstitüsü Fen Bilimleri Dergisi. 2017;33:1–9.
MLA Çoldur, Fatih vd. “Metiltrioktilamonyum Klorür Temelli Potansiyometrik Perklorat - Seçici PVC - Membran Sensör”. Erciyes Üniversitesi Fen Bilimleri Enstitüsü Fen Bilimleri Dergisi, c. 33, sy. 1, 2017, ss. 1-9.
Vancouver Çoldur F, Andaç M, Önder A. Metiltrioktilamonyum Klorür Temelli Potansiyometrik Perklorat - Seçici PVC - Membran Sensör. Erciyes Üniversitesi Fen Bilimleri Enstitüsü Fen Bilimleri Dergisi. 2017;33(1):1-9.

✯ Etik kurul izni gerektiren, tüm bilim dallarında yapılan araştırmalar için etik kurul onayı alınmış olmalı, bu onay makalede belirtilmeli ve belgelendirilmelidir.
✯ Etik kurul izni gerektiren araştırmalarda, izinle ilgili bilgilere (kurul adı, tarih ve sayı no) yöntem bölümünde, ayrıca makalenin ilk/son sayfalarından birinde; olgu sunumlarında, bilgilendirilmiş gönüllü olur/onam formunun imzalatıldığına dair bilgiye makalede yer verilmelidir.
✯ Dergi web sayfasında, makalelerde Araştırma ve Yayın Etiğine uyulduğuna dair ifadeye yer verilmelidir.
✯ Dergi web sayfasında, hakem, yazar ve editör için ayrı başlıklar altında etik kurallarla ilgili bilgi verilmelidir.
✯ Dergide ve/veya web sayfasında, ulusal ve uluslararası standartlara atıf yaparak, dergide ve/veya web sayfasında etik ilkeler ayrı başlık altında belirtilmelidir. Örneğin; dergilere gönderilen bilimsel yazılarda, ICMJE (International Committee of Medical Journal Editors) tavsiyeleri ile COPE (Committee on Publication Ethics)’un Editör ve Yazarlar için Uluslararası Standartları dikkate alınmalıdır.
✯ Kullanılan fikir ve sanat eserleri için telif hakları düzenlemelerine riayet edilmesi gerekmektedir.