Transcatheter patent ductus arteriosus closure has developed standard clinical practice. We report a moderate patent ductus arteriosus in 10-year-old girl was closed with firstly Amplatzer duct occluder II and secondly the device was embedded by a Cook detachable coil because of ductal recanalization. This case report demonstrates that to apply this combination in children is feasible and safe.
1. Moore JW, Levi DS, Moore SD, Schneider DJ, Berdjis F
Interventional treatment of patent ductus arteriosus in 2004
Catheter Cardiovasc Interv 2005;64(1):91-101
2. Turner DR, Forbes TJ, Epstein ML, Vincent JA. Early
reopening and recanalization after successful coil occlusion of
the patent ductus arteriosus. Am Heart J 2002;143(5);889-93
3. Ovaert C, McCrindle BW, Nykanen D, Freedom RM, Benson
LN. Transcatheter management of residual shunts after initial
transcatheter closure of a patent arterial duct. Can J Cardiol
2003;19(13):1493-7
4. Hofbeck M, Bartolomaeus G, Buheitel G, Esser R, Gravinghoff
L, Hoffmann W, et al. Safety and efficacy of interventional
occlusion of patent ductus arteriosus with detachable coils; a
multicentre experience. Eur J Pediatr 2000;159(5):331-7
5. Forsey J, Kenny D, Morgan G, Hayes A, Turner M, Tometzki
A, et al. Early clinical experience with the new Amplatzer
ductal occluder II for closure of the persistent arterial duct
Catheter Cardiovasc Interv 2009;74(4):615-23
6. Daniels CJ, Cassidy SC, Teske DW, Wheller JJ, Allen HD
Reopening after successful coil occlusion for patent ductus
arteriosus. J Am Coll Cardiol 1998;31(2):444-50
7. Beck C, Laser KT, Haas NA. Failure of the Amplatzer Ductal
Occluder II; Kinking of the aortic retention disk at 24 hours
Catheter Cardiovasc Interv 2010;75(7):1100-3.
Amplatzer duct occluder II embedded by cook detachable coil like a sandwich to closure of residual patent ductus arteriosus
Transkateter patent duktus arteriyozus kapatılması standart bir klinik uygulamadır. Sunumumuzda 10 yaşında bir kız hastanın orta büyüklükteki patent duktus arteriyozusu önce Amplatzer duktal oklüder II kapatılmıştır sonrada rekanalizasyon nedeni ile cihaz Cook detachable koil içine gömülmüştür. Bu vaka sunumu çocuklarda bu kombinasyonun mümkün ve güvenli olduğunu göstermektedir.
1. Moore JW, Levi DS, Moore SD, Schneider DJ, Berdjis F
Interventional treatment of patent ductus arteriosus in 2004
Catheter Cardiovasc Interv 2005;64(1):91-101
2. Turner DR, Forbes TJ, Epstein ML, Vincent JA. Early
reopening and recanalization after successful coil occlusion of
the patent ductus arteriosus. Am Heart J 2002;143(5);889-93
3. Ovaert C, McCrindle BW, Nykanen D, Freedom RM, Benson
LN. Transcatheter management of residual shunts after initial
transcatheter closure of a patent arterial duct. Can J Cardiol
2003;19(13):1493-7
4. Hofbeck M, Bartolomaeus G, Buheitel G, Esser R, Gravinghoff
L, Hoffmann W, et al. Safety and efficacy of interventional
occlusion of patent ductus arteriosus with detachable coils; a
multicentre experience. Eur J Pediatr 2000;159(5):331-7
5. Forsey J, Kenny D, Morgan G, Hayes A, Turner M, Tometzki
A, et al. Early clinical experience with the new Amplatzer
ductal occluder II for closure of the persistent arterial duct
Catheter Cardiovasc Interv 2009;74(4):615-23
6. Daniels CJ, Cassidy SC, Teske DW, Wheller JJ, Allen HD
Reopening after successful coil occlusion for patent ductus
arteriosus. J Am Coll Cardiol 1998;31(2):444-50
7. Beck C, Laser KT, Haas NA. Failure of the Amplatzer Ductal
Occluder II; Kinking of the aortic retention disk at 24 hours
Başpınar, O., Kılınç, M., & İrdem, A. (2011). Amplatzer duct occluder II embedded by cook detachable coil like a sandwich to closure of residual patent ductus arteriosus. Gaziantep Medical Journal, 17(3), 163-165.
AMA
Başpınar O, Kılınç M, İrdem A. Amplatzer duct occluder II embedded by cook detachable coil like a sandwich to closure of residual patent ductus arteriosus. Gaziantep Medical Journal. Nisan 2011;17(3):163-165.
Chicago
Başpınar, Osman, Metin Kılınç, ve Ahmet İrdem. “Amplatzer Duct Occluder II Embedded by Cook Detachable Coil Like a Sandwich to Closure of Residual Patent Ductus Arteriosus”. Gaziantep Medical Journal 17, sy. 3 (Nisan 2011): 163-65.
EndNote
Başpınar O, Kılınç M, İrdem A (01 Nisan 2011) Amplatzer duct occluder II embedded by cook detachable coil like a sandwich to closure of residual patent ductus arteriosus. Gaziantep Medical Journal 17 3 163–165.
IEEE
O. Başpınar, M. Kılınç, ve A. İrdem, “Amplatzer duct occluder II embedded by cook detachable coil like a sandwich to closure of residual patent ductus arteriosus”, Gaziantep Medical Journal, c. 17, sy. 3, ss. 163–165, 2011.
ISNAD
Başpınar, Osman vd. “Amplatzer Duct Occluder II Embedded by Cook Detachable Coil Like a Sandwich to Closure of Residual Patent Ductus Arteriosus”. Gaziantep Medical Journal 17/3 (Nisan 2011), 163-165.
JAMA
Başpınar O, Kılınç M, İrdem A. Amplatzer duct occluder II embedded by cook detachable coil like a sandwich to closure of residual patent ductus arteriosus. Gaziantep Medical Journal. 2011;17:163–165.
MLA
Başpınar, Osman vd. “Amplatzer Duct Occluder II Embedded by Cook Detachable Coil Like a Sandwich to Closure of Residual Patent Ductus Arteriosus”. Gaziantep Medical Journal, c. 17, sy. 3, 2011, ss. 163-5.
Vancouver
Başpınar O, Kılınç M, İrdem A. Amplatzer duct occluder II embedded by cook detachable coil like a sandwich to closure of residual patent ductus arteriosus. Gaziantep Medical Journal. 2011;17(3):163-5.